전차 포탑 승무원실의 내부 열/유동장에 관한 수치적 연구
남궁혁준,이경훈,박병훈,노근래,NamKoung, H.J.,Lee, K.H.,Park, B.H.,Roh, K.L. 한국군사과학기술학회 2006 한국군사과학기술학회지 Vol.9 No.2
The heavy thermal load to battle tanks can cause electronic components' malfunction and crew to be put out of action. The thermal load is generated from Internal heat sources such as electronic devices installed in the room as well as extremely hot weather. In this study, heat and flow analysis for the cabin room of a battle tank was performed to deal with this thermal problem. This study presented the validation of simulation results in comparison with those of test, the investigation of optimal flow design for effective cooling in cabin room and finally the evaluation of thermal comforts to crew.