이준호,신상완,권상호,Lee Jun-Ho,Shin Sang-Wan,Kwon Sang-Ho 대한치과보철학회 2003 대한치과보철학회지 Vol.41 No.2
Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.
다양한 구강위생기구를 이용하여 임플란트 표면의 Prophylaxis 시행시 표면형태의 변화분석
이선구,임성빈,정진형,권상호,Lee, Sun-Goo,Lim, Sung-Bin,Chung, Chin-Hyung,Kwon, Sang-Ho 대한치주과학회 2004 Journal of Periodontal & Implant Science Vol.34 No.1
It is improtant that performing prophylaxis procedure on an infected implant surface in order to treat peri-implantitis should not change the surface roughness and composition, so that the surface can be recovered to almost same condition as initial implant surface. This thesis, therefore, studied an effect of various oral hygiene instrument on implant surface. A surface roughness measurement instrument and an infection electron microscope were used to observe a change on surface. The purpose of this study was to obtain a clinical guidelines during implant care and peri-implantitis treatment. The result were as follows 1. Ra values (surface roughness value) at experimental group 1, group 2, and group 5 were increased significantly as compared with comparison group(p<0.05). 2. When compared experimental group 1 with each experimental groups at which prohylaxis procedure was performed, mean values of Ra at experimental group 2, group 3, group 6, and group 7 were decreased significantly(p<0.05). 3. Mean value of Ra was lowest at experimental group 2, and highest at experimental group 2, and highest at experimental group 5. 4. Analysis of SEM showed that was significant surface change at experimental group 2, group 3, group 4, group 5, and group 6 as compared with comparison group(X1000). 5. Analysis fo EDX showed that a quantity of Ti on surface for experimental group 6 was very similar to that for comparison group. In conclusion, air-powder abrasive and citric acid, plastic instrument are safe methods to use for performing prophylaxis procedure on implant care or for cleaning and sterilization process on treatment of peri-implantitis, based on the result that those method did not affect implant surface roughness and Ti composition.