http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Jinbong Hwang,Hae Won Jang,Bae Namgung,Mira Oh,Soyoung Kim,Dongwon Seo,Se-Na Kim,Youngmin Choi,Jin-Sik Nam,Mi-Ok Yang 한국산업식품공학회 2015 산업 식품공학 Vol.19 No.2
The analytical method for the determination of phosphorus in foods was validated by inductively coupled plasma optical emission spectrometry (ICP-OES) in terms of precision, accuracy, recovery efficiency and linearity. Regression analysis revealed good correlation coefficient, higher than 0.999. Recovery efficiencies of the minerals ranged from 90.36% to 110.63%, and the limit of detection (LOD) and the limit of quantification (LOQ) were 0.0745 mg/ kg and 0.2482 mg/kg, respectively. The value of inter-day and intra-day ranged from 1.43 to 3.23% and from 0.40 to 1.77%. The recovery efficiencies ranged from 97.8 to 110.6%. The method was also compared with Molybdenum blue colorimetric method using certified and statistically significant difference was also not observed in the between two different analytical methods. The ICP-OES method was applied to phosphorus determination in commonly consumed foods. The obtained results suggest that the method verified in the present study may be used as an official analytical method for clear understanding of phosphorus database for national health promotion.
( Jinbong Hwang ),( Hae Won Jang ),( Bae Namgung ),( Mira Oh ),( Soyoung Kim ),( Dongwon Seo ),( Se Na Kim ),( Youngmin Choi ),( Jin Sik Nam ),( Mi Ok Yang ) 한국산업식품공학회 2015 산업 식품공학 Vol.19 No.2
The analytical method for the determination of phosphorus in foods was validated by inductively coupled plasma optical emission spectrometry (ICP-OES) in terms of precision, accuracy, recovery efficiency and linearity. Regression analysis revealed good correlation coefficient, higher than 0.999. Recovery efficiencies of the minerals ranged from 90.36% to 110.63%, and the limit of detection (LOD) and the limit of quantification (LOQ) were 0.0745 mg/ kg and 0.2482 mg/kg, respectively. The value of inter-day and intra-day ranged from 1.43 to 3.23% and from 0.40 to 1.77%. The recovery efficiencies ranged from 97.8 to 110.6%. The method was also compared with Molybdenum blue colorimetric method using certified and statistically significant difference was also not observed in the between two different analytical methods. The ICP-OES method was applied to phosphorus determination in commonly consumed foods. The obtained results suggest that the method verified in the present study may be used as an official analytical method for clear understanding of phosphorus database for national health promotion.