RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

        Yuehua Li,Mingyuan Yuan,Mengmeng Yu,Zhigang Lu,Chengxing Shen,Yining Wang,Bin Lu,Jiayin Zhang 대한영상의학회 2019 Korean Journal of Radiology Vol.20 No.4

        Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48–88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7–6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

      • KCI등재

        Assessment of Myocardial Bridge by Cardiac CT: Intracoronary Transluminal Attenuation Gradient Derived from Diastolic Phase Predicts Systolic Compression

        Mengmeng Yu,Yang Zhang,Yuehua Li,Minghua Li,Wenbin Li,Jiayin Zhang 대한영상의학회 2017 Korean Journal of Radiology Vol.18 No.4

        Objective: To study the predictive value of transluminal attenuation gradient (TAG) derived from diastolic phase of coronary computed tomography angiography (CCTA) for identifying systolic compression of myocardial bridge (MB). Materials and Methods: Consecutive patients diagnosed with MB based on CCTA findings and without obstructive coronary artery disease were retrospectively enrolled. In total, 143 patients with 144 MBs were included in the study. Patients were classified into three groups: without systolic compression, with systolic compression < 50%, and with systolic compression ≥ 50%. TAG was defined as the linear regression coefficient between intraluminal attenuation in Hounsfield units (HU) and length from the vessel ostium. Other indices such as the length and depth of the MB were also recorded. Results: TAG was the lowest in MB patients with systolic compression ≥ 50% (-19.9 ± 8.7 HU/10 mm). Receiver operating characteristic curve analysis was performed to determine the optimal cutoff values for identifying systolic compression ≥ 50%. The result indicated an optimal cutoff value of TAG as -18.8 HU/10 mm (area under curve = 0.778, p < 0.001), which yielded higher sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy (54.1, 80.5, 72.8, and 75.0%, respectively). In addition, the TAG of MB with diastolic compression was significantly lower than the TAG of MB without diastolic compression (-21.4 ± 4.8 HU/10 mm vs. -12.7 ± 8 HU/10 mm, p < 0.001). Conclusion: TAG was a better predictor of MB with systolic compression ≥ 50%, compared to the length or depth of the MB. The TAG of MB with persistent diastolic compression was significantly lower than the TAG without diastolic compression.

      • KCI등재

        Calcification Remodeling Index Characterized by Cardiac CT as a Novel Parameter to Predict the Use of Rotational Atherectomy for Coronary Intervention of Lesions with Moderate to Severe Calcification

        Mengmeng Yu,Yuehua Li,Wenbin Li,Zhigang Lu,Meng Wei,Jiayin Zhang 대한영상의학회 2017 Korean Journal of Radiology Vol.18 No.5

        Objective: To assess the feasibility of calcification characterization by coronary computed tomography angiography (CCTA) to predict the use of rotational atherectomy (RA) for coronary intervention of lesions with moderate to severe calcification. Materials and Methods: Patients with calcified lesions treated by percutaneous coronary intervention (PCI) who underwent both CCTA and invasive coronary angiography were retrospectively included in this study. Calcification remodeling index was calculated as the ratio of the smallest vessel cross-sectional area of the lesion to the proximal reference luminal area. Other parameters such as calcium volume, regional Agatston score, calcification length, and involved calcium arc quadrant were also recorded. Results: A total of 223 patients with 241 calcified lesions were finally included. Lesions with RA tended to have larger calcium volume, higher regional Agatston score, more involved calcium arc quadrants, and significantly smaller calcification remodeling index than lesions without RA. Receiver operating characteristic curve analysis revealed that the best cutoff value of calcification remodeling index was 0.84 (area under curve = 0.847, p < 0.001). Calcification remodeling index ≤ 0.84 was the strongest independent predictor (odds ratio: 251.47, p < 0.001) for using RA. Conclusion: Calcification remodeling index was significantly correlated with the incidence of using RA to aid PCI. Calcification remodeling index ≤ 0.84 was the strongest independent predictor for using RA prior to stent implantation.

      • KCI등재

        Polyetheretherketone implants with hierarchical porous structure for boosted osseointegration

        Zhiyong Chen,Yu Chen,Yang Wang,JiaJia Deng,Xin Wang,Qingqing Wang,Yuehua Liu,Jiandong Ding,Lin Yu 한국생체재료학회 2023 생체재료학회지 Vol.27 No.00

        Background Good osseointegration is the key to the long-term stability of bone implants. Thermoplastic polyetheretherketone (PEEK) has been widely used in orthopedics; however, its inherent biological inertia causes fibrous tissue to wrap its surface, which leads to poor osseointegration and thus greatly limits its clinical applications. Methods Herein, we developed a facile yet effective surface modification strategy. A commonly used sulfonation coupled with “cold pressing” treatment in the presence of porogenic agent formed a three-dimensional hierarchical porous structure on PEEK surface. Subsequently, the effects of porous surface on the in vitro adhesion, proliferation and differentiation of rat bone marrow-derived mesenchymal stem cells (BMSCs) were evaluated. Finally, the osteoinduction and osseointegration of surface-porous PEEK implant were examined in the rat distal femoral defect model. Results In vitro results showed that the surface modification did not significantly affect the mechanical performance and cytocompatibility of PEEK substance, and the porous structure on the modified PEEK substrate provided space for cellular ingrowth and enhanced osteogenic differentiation and mineralization of BMSCs. In vivo tests demonstrated that the surface-porous PEEK implant could effectively promote new bone formation and had higher bone-implant contact rate, thereby achieving good bone integration with the surrounding host bone. In addition, this modification technique was also successfully demonstrated on a medical PEEK interbody fusion cage. Conclusion The present study indicates that topological morphology plays a pivotal role in determining implant osseointegration and this facile and effective modification strategy developed by us is expected to achieve practical applications quickly.

      • SCIESCOPUSKCI등재

        EXISTENCE AND UNIQUENESS OF PERIODIC SOLUTIONS FOR A KIND OF RAYLEIGH EQUATION WITH A DEVIATING ARGUMENT

        Zhou, Qiyuan,Xiao, Bing,Yu, Yuehua,Liu, Bingwen,Huang, Lihong Korean Mathematical Society 2007 대한수학회지 Vol.44 No.3

        In this paper, we use the coincidence degree theory to establish new results on the existence and uniqueness of T-periodic solutions for a kind of Rayleigh equation with a deviating argument of the form $x'+f(x'(t))+g(t,\;x(t-\tau(t)))=p(t)$.

      • KCI등재
      • Structure Analysis of 16S rDNA Sequences from Strains of Acidithiobacillus ferrooxidans

        Peng, Hong,Yang, Yu,Li, Xuan,Qiu, Guanzhou,Liu, Xueduan,Huang, Jufang,Hu, Yuehua Korean Society for Biochemistry and Molecular Biol 2006 Journal of biochemistry and molecular biology Vol.39 No.2

        Four strains of Acidithiobacillus ferrooxidans with different iron oxidation capacity were isolated from different mine drainage stations. The 16S rRNA gene of these strains were cloned and sequenced. Based on our sequences analysis on the four strain and the data on the other strains deposited in Genbank, all A. ferrooxidans may be classified into three phylogenetic groups. The analysis data showed that nucleotide variables (signature sites) were detected in 21 positions, and most of them were found in the first 800bp from 5' terminal except position 970 and 1375. Interestingly, the first 13 signature sites were located in two main regions:the first region (position 175-234) located in V2 while the second region (position 390-439) were detected in constant region between V2 and V3. Furthermore, the secondary structure and minimal free energy were determined in two regions among strains of three groups. These results may be useful in characterizing the microevolutionary mechanisms of species formation and monitoring in biohydrometallurgical application.

      • KCI등재

        Existence and Uniqueness of Periodic Solutions for a Kind of Rayleigh Equation with a Deviating Argument

        Qiyuan Zhou,Bing Xiao,Yuehua Yu,Bingwen Liu,Lihong Huang 대한수학회 2007 대한수학회지 Vol.44 No.3

        In this paper, we use the coincidence degreetheory to establish new results on the existence and uniqueness ofT-periodic solutions for a kind of Rayleighequation with a deviating argument of the formx''+f(x'(t))+g(t,x(t-tau(t)))=p(t).

      • KCI등재

        Natural History of Untreated Coronary Total Occlusions Revealed with Follow-Up Semi-Automated Quantitative Coronary CT Angiography: The Morphological Characteristics of Initial CT Predict Occlusion Shortening

        Qian Wu,Mengmeng Yu,Yuehua Li,Wenbin Li,Zhigang Lu,Meng Wei,Jing Yan,Jiayin Zhang 대한영상의학회 2018 Korean Journal of Radiology Vol.19 No.2

        Objective: To investigate the morphological changes of coronary chronic total occlusion (CTO) as determined by coronary computed tomography angiography (CCTA) follow-up using semi-automated quantitative analysis. Materials and Methods: Thirty patients with 31 CTO lesions confirmed by invasive coronary angiography and baseline/follow-up CCTA were retrospectively included. CTOs were quantitatively analyzed by a semi-automated coronary plaque analysis software (Coronary Plaque Analysis, version 2.0, Siemens) after manually determining the lesion border. Recanalized lumen was defined as the linear-like enhanced opacity traversing the non-opacified occluded segment. Other parameters, such as total occlusion length, total occlusion volume, volume with low attenuation component (< 30 Hounsfield unit [HU]), volume with middle to high attenuation component (30−190 HU) as well as the calcification volume, were also recorded. Results: Recanalized lumen was found within 48.4% (15/31) occlusions on the follow-up CCTA, compared to 45.2% (14/31) occlusions on the baseline CCTA. Eleven of 14 lesions (78.6%) with CT-visible recanalized lumen within CTOs had a shorter occlusion length on follow-up compared to only 3 of 17 lesions (17.6%) without CT-visible recanalized lumen (odds ratio, 17.1, p < 0.001). The percentage of low attenuation component of occlusions was smaller on follow-up CCTA compared to baseline value (18.1 ± 20.1% vs. 22.6 ± 19.6%, p = 0.033). Conclusion: Coronary computed tomography angiography enables non-invasive characterization of natural progression of untreated CTO lesions. Recanalized lumen within CTOs observed at baseline CCTA was associated with shortening of occlusion length on follow-up. Compared to their earlier stage, occlusions of later stage were presented with higher density of non-calcified components.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼