http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Influence of Coastal Wind on Surface Ozone and Nitrogen Oxides in Suburban Shanghai
Wenpo Shan,Peng Yang,Haixia Lu,Kefeng Ma,Zhixin Huang 한국기상학회 2016 Asia-Pacific Journal of Atmospheric Sciences Vol.52 No.5
Surface ozone, NO, NO2, and NOx were measured at a coastal site (Shihua) and a nearby inland site (Zhujing) in suburban Shanghai for the whole year of 2009. More days with ozone pollution in a longer time range were observed at the coastal site than the inland site. The diurnal variations of NOx concentrations were obviously higher at Zhujing station, while those of ozone concentrations were higher at Shihua station, indicating their different air pollution conditions. Coastal wind has significant influence on the levels and characteristics of the air pollutants. The ozone concentrations during maritime winds (MW) were much higher than those during continental winds (CW) at each of the site, while the NO and NO2 concentrations were both opposite. The ozone concentrations at Shihua station were much higher than those at Zhujing station, while the NO and NO2 concentrations were both opposite. The ozone concentrations at both of the two sites showed a distinct “weekend effects” and “weekdays effects” patterns during CW and MW, respectively. Correlation analysis of the pollutants showed that, the compounds during MW were more age than those during CW, and the compounds at Shihua were more age than those at Zhujing. The air pollutions at both of the two sites are mainly associated with the pollutants emitted in this region instead of long range transport.
Analysis of Operation Characteristics of a Diesel Generator Set with Constant‑Power Pulsed Load
Meng Shi,Puyu Wang,Jinquan Wang,Haichao Li,Ye Xu,Kefeng Huang,Jianke Li 대한전기학회 2019 Journal of Electrical Engineering & Technology Vol.14 No.6
To improve the power quality of a diesel generator set with a pulsed load in a microgrid, this paper studied the operation characteristics of the system and proposed pulsed load conditions for an actual project based on test data. For a low average pulse power and a high peak power, a new mathematical model of the pulsed load in diferent operation modes was proposed. Then, a simulation model of the microgrid was established in MATLAB/Simulink, and the operation of the system was studied considering changes in various pulsed load parameters (the peak power Pk, output duty cycle D and switching period Ts). It was verifed by tests that the simulation model is efective and can refect the operation of the system. Based on the simulation model, the operation characteristics of the system with a bivariate pulsed load were studied, and qualifcation conditions for the diesel generator set in an actual project were proposed.