http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Dark current suppression of amorphous selenium based photosensors by the ZnO hole blocking layer
Tung-Yuan Yu,Fu-Ming Pan,Cheng-Yi Chang,Tien Hu,Jenn-Fang Chen,Jia-Feng Wang,Jia-Feng Wang,Cheng-Lu Lin,Te-Ming Chen 한국물리학회 2014 Current Applied Physics Vol.14 No.5
To study the influence of defects in the hole blocking layer (HBL) on the dark current of amorphous selenium (a-Se) based photosensors, we prepared ZnO thin films by reactive sputter deposition (RSD) for the use as the HBL of the photosensors. The ZnO HBL layers prepared with different oxygen flow rates were characterized by X-ray photoelectron spectroscopy, Raman scattering analysis and photoluminescence, indicating that the density of oxygen vacancies in the ZnO thin films is significantly affected by the oxygen flow rate. The deep level transient spectroscopy measurement reveals two hole trap levels present in the RSD deposited ZnO thin films; one is at 0.94 eV and the other at 0.24 eV above the valence band edge. The electrical performance of the a-Se photosensor is largely influenced by the amount of oxygen vacancies in the ZnO thin film. The a-Se photosensor with the ZnO HBL of the most oxygen vacancies has the lowest dark current and demonstrates the highest breakdown field.
Ta-Chuan Yeh,Hsuan-Te Chu,Chia-Kuang Tsai,Hsin-An Chang,Fu-Chi Yang,San-Yuan Huang,Chih-Sung Liang 대한신경정신의학회 2019 PSYCHIATRY INVESTIGATION Vol.16 No.8
Objective Since the inflammatory process has been implicated in the pathophysiology of psychiatric disorder, an important issue emerging is to assess the test-retest reliability of cytokine measurement in healthy individuals and patients with schizophrenia. The objective of the present study was to investigate the test-retest reliability of bead-based multiplex immunoassay technology (BMIT) for cytokine measurement by using a Bland-Altman plot (BAP). Methods Twenty healthy individuals and twenty patients with schizophrenia were enrolled, and a 17-plex cytokine assay was used to measure inflammatory biomarkers at baseline and two weeks later. The test-retest reliability was examined by BAP, 95% limits of agreement (LOA), intraclass correlation coefficient (ICC), and coefficient of repeatability (CoR). Results In the healthy controls, only interleukin (IL)-2, IL-13, IL-10, IL-17, and macrophage inflammatory protein-1β showed excellent ICC. The BAP with 95% LOA determined that 13 cytokines showed acceptable 95% LOA for a 2-week test-retest reliability, and only IL-1β, IL-12 and tumor necrosis factor (TNF)-α had significant test-retest bias. The CoR of cytokines varied significantly, ranging from 1.72 to 218.1. Compared with healthy controls, patients with schizophrenia showed significantly higher levels of IL-5, IL-13, and TNF-α and significantly lower levels of IL-4, IL-12, and interferon-gamma (IFN-γ). Of these six cytokines, IL-12 and TNF-α were considered suboptimal reliability. Conclusion The findings from ICC and CoR implied that the test-retest reliability of BMIT for cytokine measurement were suboptimal. However, the BAP with 95% LOA confirmed that BMIT can reliably distinguish schizophrenia from healthy individuals in cytokine measurement, while significant within-subject variation and between-group overlapping were evident in cytokine expression.