http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Liu, Zhe-Ming,Ge, Xiao-Lin,Chen, Jia-Yan,Wang, Pei-Pei,Zhang, Chi,Yang, Xi,Zhu, Hong-Cheng,Liu, Jia,Qin, Qin,Xu, Li-Ping,Lu, Jing,Zhan, Liang-Liang,Cheng, Hong-Yan,Sun, Xin-Chen Asian Pacific Journal of Cancer Prevention 2015 Asian Pacific journal of cancer prevention Vol.16 No.8
Background: Radiotherapy is an important treatment of choice for breast cancer patients after breast-conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. Materials and Methods: Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. Results: All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left-sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. Conclusions: Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.
Ming-Chieh Cheng,Shih-Ping Liu,Yao-Chi Chuang,Karina Chin Po Hsu,Po-Ming Chow 대한비뇨의학회 2022 Investigative and Clinical Urology Vol.63 No.1
Purpose: Male urinary incontinence (UI) is a global health issue associated with bothersome symptoms which affect daily life. This study aims to evaluate the prevalence of male UI in China, Taiwan, and South Korea and to determine if UI is an independent risk factor affecting the health-related quality of life (HRQoL), mental health, work limitations, and healthcare seeking behavior. Materials and Methods: A post-hoc analysis was conducted on the LUTS Asia database which was collated from a cross-sectional, population-based internet survey in China, Taiwan, and South Korea. Prevalence of male UI was assessed, and the effect on HRQoL, Hospital Anxiety and Depression Scale (HADS) depression and anxiety scores, work performance, and healthcare seeking behaviors was determined using univariate and multivariate analyses. Results: A total of 4,076 male participants were surveyed. Prevalence of male UI was 17.3%. UI adversely affected the HRQoL in both physical and mental domains. Both multivariate and univariate analyses showed that male UI could be correlated with a negative effect on the HADS anxiety and depression scores. Multivariate analysis suggested that work difficulties were correlated to the presence of UI. Up to 28% of participants who reported urge UI only did not adopt any management measures. Conclusions: UI is common in men over 40 years and adversely impacts HRQoL. It is an independent risk factor for anxiety and depression and may cause significant work limitations. Despite these negative effects, many men still do not seek any intervention.
A new power supply strategy for high power rectifying units in electrolytic copper process
Liu He-Miao,Zhao Yu-Lian,Cheng Yan-Ming,Wu Jing,Al Shurafa Mahmoud A. M.,Liu Cheng,Lee Il-Kyoo 대한전기학회 2022 Journal of Electrical Engineering & Technology Vol.17 No.2
For achieving the minimum energy consumption in electrolytic copper process, this paper proposes a power supply optimization strategy based on the improved BP neural network for high-power electrolytic copper rectifying units to eff ectively improve the utilization rate of electric energy, reduce the production cost, and achieve high effi ciency and energy saving. Aiming to operation scenarios including normal operation of rectifi ers, fault of random one rectifi er, fault of random two rectifi ers and number change of electrolytic tanks, the output current of each rectifi er, transformer gears and control angle of thyristor are obtained under these four scenarios by the proposed power supply strategy. The simulation results indicate that compared with BP neural network and PSO optimizing BP(PSO-BP)neural network, the prediction error of power supply strategy of GA optimizing BP (GA-BP) neural network is the minimum. Consequently, the optimal control of the output current of each rectifi er is obtained by using GA-BP neural network, and the stabilized current precision of total output current can be kept at 0.003–0.005, which verifi es the eff ectivity and feasibility of the proposed power supply optimization strategy, which provides valuable guidance and reference for the future design of high-power power supply system in electrolytic copper or other electrolytic metals.
Liu, Jia,Ge, Yang-Yang,Zhu, Hong-Cheng,Yang, Xi,Cai, Jing,Zhang, Chi,Lu, Jing,Zhan, Liang-Liang,Qin, Qin,Yang, Yan,Yang, Yue-Hua,Zhang, Hao,Chen, Xiao-Chen,Liu, Zhe-Ming,Ma, Jian-Xin,Cheng, Hong-Yan,S Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.16
Radiation therapy is an important treatment for head and neck squamous cell carcinoma (HNSCC). However, how to promote radiation sensitivity in HNSCC remains a challenge. This study aimed to investigate the radiosensitizing effects of fenofibrate on HNSCC and explore the underlying mechanisms. HNSCC cell lines CNE-2 and KB were subjected to ionizing radiation (IR), in the presence or absence of fenofibrate treatment. Cell growth and survival, apoptosis and cell cycle were evaluated. In addition, CNE-2 cells were xenografted into nude mice and subjected to IR and/or fenofibrate treatment. The expression of cyclinB and CDK1 was detected by Western blotting. Our results showed that fenofibrate efficiently radiosensitized HNSCC cells and xenografts in mice, and induced apoptosis and G2/M arrest via reducing the activity of the CDK1/cyclinB1 kinase complex. These data suggest that fenofibrate could be a promising radiosensitizer for HNSCC radiotherapy.
Yan-Ming Cheng,이민우,차재상,Cheng Liu,이일규 대한전기학회 2019 Journal of Electrical Engineering & Technology Vol.14 No.3
The rapid development of wireless power transfer (WPT) in mobile devices and Internet of Things (IoT) Technologies inspires the research interest to support the wireless power charging capability on digital living equipment to manage energy sources eff ectively. As energy consumption in our day to day life is steadily increases the demand, the trend for energy harvesting technology also grows and there is an increasing number of an independent IoT based microgrid facility is built using solar panels in smart home. The digital living things are usually placed in a narrow space with microgrid facility. However, The IoT connected digital living is placed independently in a large space. The WPT will give interference to electrical equipments and electric utility meter in microgrid facility. This paper is focused on analyzing the coexistence between WPT and electric utility meter in an IoT based smart home microgrid facility. The separation distance between WPT and electric utility meter and the allowable numbers of WPT are suggested in order to protect electric utility meter from interference of WPT on the basis of interference scenario. The Monte Carlo method is used for the impact analysis of WPT supporting digital living things on energy utility meter built-in with Near Field Communication.
Yan-Ming Cheng,Cheng Liu,Jing Wu,He-Miao Liu,Il-Kyoo Lee,Jing Niu,조주필,구경완,Min-Woo Lee,우덕근 대한전기학회 2020 Journal of Electrical Engineering & Technology Vol.15 No.6
This paper mainly focuses on the control strategy for phase-shifting full-bridge soft switching electrolytic silver power supply based on Zero Voltage Switching (ZVS) soft switching technology. Taking into consideration the low performance of traditional PID control for phase-shifting full-bridge soft-switching, this paper introduce a PID improved by Back Propagation (BP) neural network with one single learning rate which is used to calculate weights from the input layer to the hidden layer and weights from the hidden layer to the output layer. After testing, it is found that setting independent learning rate for calculation of weights from the input layer to the hidden layer and weights from the hidden layer to the output layer which will not have an adverse eff ect on the design of the controller. Instead, the learning rate can be set according to the respective characteristics of the weights between the two layers, which is called double learning rate BP neural network PID. The simulation results indicate that compared with the single learning rate BP neural network PID control, the double learning rate BP neural network control has higher response speed, less over-shoot, short time to enter the steady state and strong immunity.
Clarifying Warhead Separation from the Reentry Vehicle Using a Novel Tracking Algorithm
Cheng-Yu Liu,Yu-Ming Sung 대한전기학회 2006 International Journal of Control, Automation, and Vol.4 No.5
Separating a reentry vehicle into warhead and body is a conventional and efficient means of producing a huge decoy and increasing the kinetic energy of the warhead. This procedure causes the radar to track the body, whose radar cross section is larger, and ignore the warhead, which is the most important part of the reentry vehicle. However, the procedure is difficult to perform using standard tracking criteria. This study presents a novel tracking algorithm by integrating input estimation and modified probabilistic data association filter to solve this difficulty in a clear environment. The proposed algorithm with a new defined association probability in this filter provides a good tracking capability for the warhead ignoring the radar cross section. The simulation results indicate that the errors between the estimated and the warhead trajectories are reduced to a small interval in a short time. Therefore, the radar can produce a beam to illuminate to the right area and keep tracking the warhead all the way. In conclusion, this algorithm is worthy of further study and application.
Key Application Technologies of High Efficiency Power Quality Control Systems
Liu, Ding-Guo,Shuai, Zhi-Kang,Tu, Chun-Ming,Cheng, Ying,Luo, An The Korean Institute of Power Electronics 2013 JOURNAL OF POWER ELECTRONICS Vol.13 No.3
Large capacity reactive power compensation and harmonic control in the low-voltage grid of an enterprise, are important technical means to improve power quality and reduce power loss. In this paper, the principle of an efficient power quality controller is analyzed. Then, key application technologies of the HPQC which would influence the performances of the HPQC are studied. Based on an analysis of the harmonic shunt problem, a frequency dividing control strategy of the HPQC continuous subsystem is proposed. A parameter design method of the HPQC discrete subsystem and its installation method are also proposed to ensure the system compensation effect. HPQC systems have been designed for a copper foil plant. The effectiveness of this paper has been verified by the simulation and application results.