http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김형식,김창회,김영수,Kim Hyung-Sik,Kim Chang-Whe,Kim Young-Soo 대한치과보철학회 1994 대한치과보철학회지 Vol.32 No.3
The denture may be fractured accidentally by an impact while outside the mouth, or may be cracked or broken while in service in the mouth. The latter is generally a fatigue failure caused by repeated flexure over a period of time. This investigation compared the flexural fatigue resistance, the impact force and the transverse strength of two denture base materials with and without the grid strengthener, the T300, the T800 and the Kevlar fiber to evaluate the fracture resistance. The distribution and behavior of fibers across fracture lines were examined by Hi-Scope Compact Microvision System. Through analyses of the data from this study, the following conclusions were obtained. 1. The flexural fatigue resistance, impact strength and transverse strength of high impact strength resin were higher than those of conventional heat polymerizing resin, but statistically there was no significant difference(p>0.05). 2. All specimens with and without the grid strengthener did not show significant differences in the flexural fatigue, the impact and the transverse strength test(p>0.05). 3. All specimens reinforced with the T300, the T800 and the Kevlar fiber showed significant increase of the fatigue resistance and the impact force(p<0.05). 4. All specimens reinforced with the T800 and the Kevlar fiber showed significant increase of the transverse strength(p<0.05). 5. All specimens reinforced with the T300, the T800 and the Kevlar fiber exhibited greenstick fractures. The fibers tended to remain enveloped in the resin, resisting pull-out.
포스터 발표 - 고분자공업분과 : 계면 가교에 의한 라텍스 필름의 구조 , 기계적 물성 및 강도변화에 관한 연구
김형식,이덕연,박영준,김중현 ( Hyung Sik Kim,Doug Youn Lee,Young Jun Park,Jung Hyun Kim ) 한국공업화학회 1997 한국공업화학회 연구논문 초록집 Vol.1990 No.3
N/A The viscoelastic properties of latex-based paper coatings affect the performance of the coated sheet. Particle/particle or interfacial contacts and molecular interdiffusion of polymer chains between adjacent latex particles during the coalescence phase of film formation has been shown to be of critical importance in the development of the final mechanical strength of a latex polymer film. In addition to the development of the final mechanical strength of film, interfacial x-linking play a important role in changing of water-sorption amounts of polymer film.
전기자동차용 OBC 일체형 1.5㎾급 LDC 컨버터에 대한 연구
김형식(Hyung-Sik Kim),전준혁(Joon-Hyeok Jeon),김희준(Hee-Jun Kim),안준선(Joon-Seon Ahn) 한국정보전자통신기술학회 2019 한국정보전자통신기술학회논문지 Vol.12 No.4
PHEV(Plug in Hybrid Electric Vehicle)와 BEV(Battery Electric Vehicle)는 모터 및 차량 전장 시스템의 구동을 위하여 고전압 배터리를 사용하며 이를 충전시켜주는 OBC(On-Board Charger)와 고전압에서 저전압으로 전력변환을 해주는 LDC(Low DC/DC Converter)가 반드시 필요하다. OBC와 LDC는 차량에 독립적인 시스템으로 동작 하며 개별 공간을 사용하기 때문에 이를 통합한 시스템을 활용하여 무게 및 사용 공간 확보에 대한 필요성이 대두 되고 있다. 본 논문은 LDC 트랜스포머의 설계를 단순화하여 절연형 전류원 컨버터를 사용한 OBC에 통합이 가능한 1.5㎾급 LDC컨버터에 대하여 제안하였다. 제안된 LDC는 양방향 벅-부스트 컨버터의 고정된 임의의 출력 전압을 사용하여 LDC의 최종 출력 전압의 제어가 가능하기 때문에 기존의 OBC-LDC 통합 시스템과 비교하여 배터리 전압 사용 범위, 컨버터의 Duty Ratio 및 OBC의 출력 턴 비를 고려한 트랜스포머 설계에 대한 부분을 단순화 할 수 있는 장점을 가지고 있다. 제안된 LDC의 시제품을 제작하여 200V ~ 400V의 입력 전압에서 정상 동작을 확인 하였으며 정격 부하 조건에서 최대 효율 91.885%를 달성 하였다. 또한 OBC-LDC통합 시스템 구축을 통해 약 6.51L의 부피를 달성 하였으며 기존 독립적인 시스템에 비해 15.6% 저감되어 공간 확보에 대한 이점을 확인 할 수 있었다. PHEV(Plug in Hybrid Electric Vehicle) and BEV(Battery Electric Vehicle) equip high voltage batteries to drive motor and vehicle electric system. Those vehicle require OBC(On-Board Charger) for charging batteries and LDC(Low DC/DC Converter) for converting from high voltage to low voltage. Since the charger and the converter actually separate each other in electrical vehicles, there is a margin to reduce the vehicle weight and area of installation by integration two systems. This paper studies a 1.5kW LDC converter that can be integrated into an OBC using an isolated current-fed converter by simplifying the design of LDC transformers. The proposed LDC can control the final output voltage of the LDC by using a fixed arbitrary output voltage of the bidirectional buck-boost converter, so that Compared to the existing OBC-LDC integrated system, it has the advantage of simplifying the transformer design considering the battery voltage range, converter duty ratio and OBC output turn ratio. Prototype of the proposed LDC was made to confirm normal operation at 200V ~ 400V input voltage and maximum efficiency of 91.885% was achieved at rated load condition. In addition, the OBC-LDC integrated system achieved a volume of about 6.51L and reduced the space by 15.6% compared to the existing independent system.
랫드에서 인체 재조합 적혈구 조혈인자, rHuEPO의 13주 정맥투여 아만성독성에 관한 연구
김형식,곽승준,천선아,박현선,한하수,임소영,안미영,김원배,안병옥,홍성렬,이병무,Kim, Hyung-Sik,Kwack, Seung-Jun,Chun, Sun-Ah,Park, Hyun-Sun,Han, 한하수,Lim, So-Young,Ahn, Mi-Young,Kim, Won-Bae,Ahn, Byoung-Ok,Hong, Sung-Youl,Lee, Byung-Mu 한국독성학회 1998 Toxicological Research Vol.14 No.3
A recombinant human erythropoietin (rHuEPO) was administered intravenously at dosage levels of 0, 100, 500, and 2500IU/kg/day for a period of 3 weeks. There were no observed clinical signs and deaths related to treatment in all groups tested. Decreases in body weight gain and food consumption were observed only in males of 2,5000IU/kg group after 2 weeks. In hematological parameters, erythrocyte content, hematocrit values and hemoglobin concentration were dose- dependently increased in rHuEPO treated groups. The ratio between kidney weight and whole body weight was significantly increased in females of 500 and 2,500IU/kg groups. The spleen weight was also increased in both sexes of 500 and 2,500IU/kg groups. However, the absolute weight change of other organs was not observed. In histopathological examinations, the renal tubular basophilia was observed only in males and females of 2,500IU/kg groups. From these results, it is concluded that the no-observed adverse effect level (NOAEL) of rHuEPO is 100 IU/kg in rats in the present study.
수종의 화학소독제에 침적시킨 고무인상체의 크기안정성에 관한 연구
김형식,김창회,Kim, Hyung-Sik,Kim, Chang-Whe 대한치과보철학회 1989 대한치과보철학회지 Vol.27 No.2
Dental impression materials often become contaminated with patients' saliva and blood which creates the potential for cross-infection. It was the purpose of this study to investigate the effects of disinfection of three different rubber impression materials with four different disinfecting solutions. Polysulfide, vinyl polysiloxane and polyether impression materials were mixed according to the manufacturer's directions and samples were formed on a stainless steel model. On removal from the standard model, impressions were immersed in a disinfectant (acid-potentiated glutaraldehyde, phenollic compound, chlorine compound, iodophor) at room tempera tures for ten minutes. After disinfection, the distance between reference points(linear dimension) was measured using the non-contact automatic cordinate measuring projector(MZ-1, Nikon). Through statistical analyses on the data from this study,. the following conclusions were obtained. 1. Polysulfide, vinyl polysiloxane impressions were disinfected without dimensional change.(p>0.05) 2. Polyether impressions which were immersed in acid-potentiated glutaraldehyde were statistically different from control group.(p<0.05) But the amount of shrinkage(0.04%) would not be clinically significant. 3. By immersion of polysulfide, vinyl polysiloxane, polyether impressions in Banicide, Biocide, Multicide plus, sodium hypochlorite for ten minutes, clinically accurate impressions were obtained without dimensional change.
관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료
김형식(Hyung-Sik Kim),고일현(Il-Hyun Koh),김성국(Sung-Guk Kim),천용민(Yong-Min Chun),김성재(Sung-Jae Kim),강호정(Ho-Jung Kang) 대한견주관절의학회 2011 대한견주관절학회지 Vol.14 No.1
목적: 견갑골 전방 관절와 분쇄 골절에 대해 관절경하 정복 및 AO 무두 압박 나사를 이용하여 골편을 고정한 증례를 보고하고자 한다. 대상 및 방법: 31세 남자로 내원 2주 전 추락 후 발생한 좌측 견관절의 전방 관절와 분쇄 골절에 대하여 관절경하에서 골절을 정복한 후, 표준 전상방 삽입구를 통해 1.1 mm K 강선을 가이드핀으로 삽입하고 AO 무두 압박 나사로 골편을 고정하였다. 결과: 수술 후 12개월째 견관절의 운동 범위는 정상 범위로 회복 되었으며, 골절은 유합을 얻었고 일상 생활에 불편감은 없었다. 결론: AO 무두 압박 나사는 나사의 길이가 다양하여 작은 관절와 골편에 사용하기 적합하고, 가이드 핀의 길이가 상대적으로 짧으나 1.1 mm K 강선으로 대체가 가능하며, 나사 돌리개 (screw driver)나 천공기 (drill bit) 등의 동반 기구의 길이가 길어 비교적 깊은 위치의 견갑과 골절의 고정에 사용하기 편리하여 관절경적 고정술 시 유용하게 이용할 수 있을 것으로 생각된다. Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.