http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Photoferroelectric 반도체의 광학적 특성연구 Ⅱ : (BiSI, BiseI, BiSI : Co 및 BiseI : Co 단결정의 광학적 특성에 관한 연구)
고재모(Jae-Mo Goh),윤상현(Sang-Hyun Yun),김화택(Wha-Tek Kim),최성휴(Sung-Hyu Choe),김형곤(Hyung-Gon Kim),김창대(Chang-Dae Kim),권숙일(Sook-Il Kwun) 한국진공학회(ASCT) 1992 Applied Science and Convergence Technology Vol.1 No.2
BiSI, BiSI : Co, BiseI 및 BiseI : Co 단결정을 고순도의 성분원소와 8.6 mole% 과잉의 Iodine를 투명석영관내에 넣고 진공봉입하여 합성한 ingot를 사용하여 수직 Bridgman 방법으로 성장시켰다. 성장된 단결정은 orthorhombic 구조였고, energy band 구조는 간접전이형으로 293K 에서 광학적 energy gap은 각각 1.590eV, 1.412eV, 1.282eV 및 1.249eV로 주어지며, energy gap의 온도의존성은 Varshni 방정식으로 잘 표현된다. Cobalt를 첨가할 때 나타나는 불순물 광흡수 peak는 T_d Symmetry 점에 위치한 Co^(2+), Co^(3+) ion의 energy 준위들 사이의 전자전이에 의해서 나타난다. Single crystals of BiSI, BiSI : Co, BiSel, and BiSel : Co were grown by the vertical Bridgman method using the initial ingots obtained from the stoichiometric mixture of Bi, S, Se, and I (excess of 8.6 mole%) elements of a high purity. It has been found that these single crystals have an orthorhombic structure and indirect optical transitions. At 293 K the indirect-band gap of these crystals is given by 1.590 eV for BiSI, 1.412 eV for BiSI : Co, 1.282 eV for BiSel, and 1.249 eV for BiSel : Co, respectively. The temperature dependence of the optical energy gaps is well fitted with the Varshni equation. The optical absorption peaks of cobalt impurity in these single crystals are attributed to the electronic transitions between the split energy levels of CO^(2+) and Co^(3+) ions located at T_d sites of the host material.
발전소용 4.16 kV급 차단기에서 감전사고 사례 분석
박남규,송재용,김진표,고재모,Park, Nam-Kyu,Song, Jae-Yong,Kim, Jin-Pyo,Goh, Jae-Mo 한국안전학회 2014 한국안전학회지 Vol.29 No.4
This paper describes electric shock accidents on a 4.16 kV class circuit breaker for power plant. Electric shock accidents mostly involve damage of human life, in comparison with electrical fire, rate of human death tend to be higher in electric shock accidents. Specially, in a high voltage facilities rate of human death comprised about 43.7% by electric shock accidents. If electric shock accidents happen in a 4.16 kV class circuit breaker for power plant, then the power plant discontinue power production. Electric shock accidents in a power plant have a great ripple effect such as an electric power shortage. In this paper, we analyzed electric shock accidents on a 4.16 kV class circuit breaker for power plant. From the analysis results, we confirmed a cause of electric shock accidents on a 4.16 kV class circuit breaker, it happened by defect of interlock equipment or occurrence of breakdown between first feeder contactor and shielding plate. In order to reduce electric shock accidents on a 4.16 kV class circuit breaker, the power plant should consider improvement of interlock equipment and insulation of feeder contactor in circuit breaker.
차량에 장착된 보조배터리 발화 사례에 대한 실험적 연구
우승우(Seungwoo Woo),현병수(Byungsoo Hyun),사승훈(Seunghun Sa),고재모(Jae Mo Goh) 한국화재소방학회 2021 한국화재소방학회 학술대회 논문집 Vol.2021 No.추계
본 연구에서는 차량 내에 추가로 장착된 리튬이온 보조배터리에서 발화된 것으로 의심되는 다수의 화재 사례를 기반으로 한 실험적 결과를 다루었다. 일반적으로 리튬이온 배터리는 발화 후 연소된 배터리 잔해에 남아있는 흔적을 통한 원인 분석이 어려워, 구체적인 발화원인이 배터리셀의 제조 결함 문제인지 아니면 과충전 보호회로(PCM 또는 BMS)와 같은 배터리셀을 관장하는 주변 시스템의 문제인지를 구분하기가 어려우나, 본 연구에서 확인된 사례의 경우, 모두 화재직전 보조배터리 전압의 급진적인 상승이 확인되었다. 이를 토대로, 배터리셀의 제조결함 대비 과충전을 보호하는 회로와 관련한 시스템에 문제가 발생한 것을 의심할 수 있었으며, 다양한 차종의 얼터네이터(Alternator)충전 전압을 확인하고, 화재가 발생한 보조배터리 비교품 분석 및 충전 실험 등을 통해 구체적인 발화 메커니즘을 실험적으로 확인함으로, 유사 화재 사례에 대한 구체적인 발화원인 파악에 활용하고자 한다.