양성철,최재곤,Yang, Sung-Chul,Choi, Jae-Gon 한국도로학회 2008 한국도로학회논문집 Vol.10 No.2
Shear test procedure for concrete-dowel interaction was proposed along with determination of dowel support reaction factor or shear spring stiffness constant using the spreadsheet example. For this task, three AASHTO-type standard specimens were prepared to simulate behavior of the jointed concrete pavement. A side support system was adopted to minimize twisting of the test specimen which had been observed in a preliminary test. A typical elastic behavior of the dowel-concrete interaction was observed from several test loops of loading, unloading and reloading procedures. However load versus slab displacement represents to be nonlinear. Test results show that the dowel support reaction factor ranges from 550-880 GN/m3, which is 1.4-2.2 times greater than 407GN/m3 proposed by Yoder and Witczak. This is because less torsional distraction was occurred with the help of a side support system adopted in this experiment. The dowel support reaction factor or shear spring stiffness constant obtained from the procedures proposed in this paper may be used as a reference data for the structural analysis of jointed concrete pavement. 본 연구에서는 콘크리트포장의 디웰바 전단시험 절차와 실험결과를 이용하여 PC 스프레드시트에서 다웰바의 지지력계수와 전단 스프링 강성계수를 산정하는 절차를 제시하였다. 세 개의 시험체를 통해 AASHTO의 다웰바 전단시험을 수행하여 콘크리트 포장의 불연속면에서의 전단거동을 모사하였다. 예비실험을 통해 발생한 비틀림 변형을 최소화하기 위해 측면 고정대 사용하여 실험하였다. 초기하중에서의 하중의 재하(loading), 제하(unloading), 재재하(reloading)를 반복수행한 결과 탄성적인 거동을 보여준다. 그러나 전체 하중 범위에서는 다웰바의 지지력계수 또는 전단 스프링 강성계수는 슬래브의 상대 처짐 또는 재하하중에 따라 비선형으로 거동함을 보여준다. 본 실험에서 얻어진 다웰의 지지력계수는 550-880GN/m3으로서 Yoder와 Witczak이 제안하는 407GN/m3보다는 1.4-2.2배가 크게 산정되었다. 이는 측면 고정대를 사용함으로서, 실험시 예상되는 비틀림 변형이 기존의 실험에 비해 적었던 것으로 판단된다. 본 실험에서 얻어진 다웰의 지지력계수 또는 전단 스프링 강성계수는 다웰바를 이용한 콘크리트 불연속면의 구조해석 시 참고자료로 활용될 수 있다.
재하시험에 의한 댐체 공도교 거동변화 분석 및 안전성 평가
이태근 ( Lee Tae Geun ),최홍석 ( Choi Hong Seok ),이경수 ( Lee Kyeong Su ),최재곤 ( Choi Jae Gon ),오정근 ( Oh Jeong Keun ) 한국구조물진단유지관리공학회 2018 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.22 No.1
Load test is performed to obtain the data to evaluate load carrying capacity and check static & dynamic characteristics of a structure by estimating the real behavior of bridge due to loading the load. The subject facility in this paper is a bridge located on the spiilway of dam and traffic is relatively less than most brige. Considering the age and operation rules of a dam, however, load test and structure programming analysis were performed to check current conditions for structure under in-depth inspection and the results of that analysis are shown.
梁聖哲,崔栽坤 홍익대학교 산업기술연구소 2006 産業技術 Vol.16 No.-
This study was performed to investigate the characteristics of drying shrinkage for concrete slabs. Two different fine aggregates such as normal sand(ns330) and crushed sand(cs330), and a concrete mix with cement content of 370kg/m3(cs370) and two different volume-surface ratios of 22.2 and 300 mm were varied in this study. To simulate the volume-surface ratio of a real concrete pavement slab, three-layer epoxy coating and wrapping method was adopted to prevent the evaporation at the part of specimen surfaces. Test results show that as the volume-surface ratio increases, drying shrinkage decreases dramatically.