      • 전산화 단층촬영창치의 정도관리에 관한 연구

        조평곤,이창엽,Cho Pyong Kon,Lee Chang Yeop 대한방사선사협회 2002 대한방사선사협회지 Vol.28 No.1

        Purpose The quality assurance in a computed tomography gives a definition to be all the activity so as to optimize the performance of the device and keep an invariable quality of image, and it is to raise a high diagnostic efficiency to obtain a much info

      • KCI등재후보

        흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법

        조평곤(Pyong Kon Cho) 한국방사선학회 2013 한국방사선학회 논문지 Vol.7 No.3

        이 연구의 목적은 흉부, 복부 X선 검사 시 호흡, 위치 잡이, 촬영 중 움직임 등이 있을 때 영상에 어느 정도의 영향이 있는지를 알아보고 가능한 많은 양의 정보를 포함하고 있는 영상을 만들기 위함이다. 연구방법은 병원에서 가장 많이 촬영되어지고 있는 검사 중 선 자세 흉부 후전방향 X선 검사 와 누운 자세 복부 전후방향 X선 검사에서 호흡을 들이 마신상태, 내 쉰 상태, 움직임이 있는 상태에서 각 각 X선 촬영을 한 후 각 부위 별 영상평가기준을 적용하여 평가하였다. 연구 결과 선 자세 흉부 후전방향 X선 검사는 숨을 내 쉰 상태, 조사 중 미세한 움직임이 있는 경우 보다 숨을 들이 마신상태에서 촬영한 영상에서 가장 많은 정보가 포함되어있는 것을 확인 할 수 있었다. 누운 자세 복부 전후방향 X선 검사는 숨을 들이 마신상태, 움직임이 있는 경우 보다 숨을 내 쉰 상태 에서 촬영한 영상에서 가장 많은 정보가 포함되어있는 것을 알 수 있었다. 이와 같은 연구결과에서와 같이 일반 X선 검사의 경우 검사부위, 검사목적에 따라서 호흡 또는 검사 중 움직임 등에 따라 영상에서 발견할 수 있는 정보에 많은 차이가 있음을 알 수 있었다 The purpose of this study is to examine how much the movement at X-ray examinations like breathing or the positioning affects the image during chest or abdomen X-ray examination so as to create an image containing information as much as possible. The study method adopted is doing the X-ray in each of the states including breathing (inspiration & expiration) and movement in the standing chest PA X-ray and simple abdomen X-ray among the kinds of examination selected the most in hospitals and then evaluating them by applying the standards of image evaluation for each region. According to the study result, about the standing chest PA X-ray, the images taken at inspiration contain more information than those taken at expiration or having subtle movement during the examination. About the simple abdomen X-ray, the images taken at expiration contain more information than those taken at inspiration or movement. The above study results imply that regarding general X-ray examination, information we can find from the images may differ significantly according to the region examined, examination purpose, or movement during the examination like breathing.

      • KCI등재

        흉부 X선 촬영 시 산란선 분포 연구

        조평곤(Pyong-Kon Cho) 한국콘텐츠학회 2012 한국콘텐츠학회논문지 Vol.12 No.7

        흉부 X-선 촬영 시 피사체의 유무, 촬영실내 X선관과 수광계 (image receptor), 환자 보기창 앞, 환자대기실 출입문 외측, 출입문 개폐여부, 방사선 관계 종사자 출입문 외측, 방사선 관계 종사자 출입문 개폐여부 등으로 구분하여 공간산란선발생을 알아보기 위한 연구로 공간산란선발생에 대한 연구 결과 피사체가 있을 때 수광계 (image receptor) 위치; Chest PA: 663 ± 3.4 mR/h, Chest Lateral: 2,067 ± 3.7 mR/h, X선관 위치; Chest PA: 293 ± 2.1 mR/h, Chest Lateral: 927 ± 1.9 mR/h, 환자대기실 출입문 외측 열고; Chest PA: 17 ± 1.6 mR/h, Chest Lateral: 88 ±} 2.6 mR/h, 방사선 관계 종사자 촐입문 외측 열고; Chest PA: 3 ± 1.6 mR/h, Chest Lateral: 19 ± 1.6 mR/h), 피사체의 두께가 두꺼울수록 각 각의 측정지점에서산란선 발생이 많았고, 출입문을 닫고 측정한 경우 산란선이 더 적었다. 그러므로 방사선 관계종사자는 촬영실내 산란선 분포에 대한 정확한 정보를 인지하여 불필요한 방사선 피폭을 줄일 수 있도록 노력해야 한다. This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist’s entrance door, and the opening of the radiological technologist’s entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.

      • KCI등재후보

        앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구

        조평곤(Pyong-Kon Cho) 대한방사선과학회(구 대한방사선기술학회) 2011 방사선기술과학 Vol.34 No.3

        상지 검사(upper extremity X-ray examinations, UEX) 시 환자 위치 잡이로 가장 많이 활용되고 있는 앉은 자세 상지 X-ray 검사(sitting position upper extremity X-ray examinations, SUEX) 시 방사선에 민감한 생식샘과 목적장기 이외 부위에 대한 피폭이 크다고 판단되어 의료기관 별 SUEX 시 납 앞치마(Apron) 착용 유무와 생식샘 및 목적장기 이외 부위에 대한 방사선 피폭과 피폭선량 감소 방안에 대한 연구 결과 거리가 멀어 질수록, 조사야 조절장치를 가능한 목적장기 부위로 제한 조절할수록, 피사체의 두께가 얇을수록 방사선에 의한 피폭은 감소하였고, 생식샘 차폐 유무에 따른 피폭은 생식샘을 차폐했을 때 약 10~50%의 저감화 효과를 얻을 수 있었다. 또한 검사 시 apron 착용 유무에 대한 조사에서는 대부분의 경우 apron을 착용하지 않은 것으로 조사되어 시급히 시정되어야 될 것으로 생각된다. Sitting position upper extremity X-ray examinations (SUEX) is the most widely used patient positioning method for upper extremity X-ray examinations. For this method, the radiation dose is considerable for relatively less interesting organs. We investigated whether patients need to wear the apron during the examination or not. We also studied the examination methods which can reduce the radiation dose. The results showed that radiation dose was reduced as the distance of source to patient becomes longer and the thickness of object grows higher.

      • KCI등재후보

        Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations

        조평곤(Pyong-Kon cho),김유현(You-Hyun Kim),최종학(Jong-Hak Choi),이기열(Ki-Yeol Lee),김형철(Hyung-Cheol Kim),김장섭(Jang-Seob Kim),신동철(Dong-Chul Shin),이성현(sung-Hyun Lee),이준협(Jun-Hyub Lee),신귀순(Gwi-Soon Shin) 대한방사선과학회(구 대한방사선기술학회) 2009 방사선기술과학 Vol.32 No.4

        슬라이스 두께(slice thickness)와 선속시준(beam collimation, BC)의 변화에 따른 CT gantry aperture 내의 선량 분포와 영상의 질을 알아보고자 하였다. CT장치로는 64-slice MDCT 스캐너(Brilliance 64, Philips, Cleveland, USA)를 사용하였다. 피사체가 없는 경우(air scan)의 선량측정을 위해 CT용 전리함을 gantry aperture내의 회전중심점(isocenter)과 12시, 3시, 6시, 9시 방향에서 회전중심점으로부터 5 cm 간격으로, 30 cm까지 BC를 변화시키면서 각각 측정 하였다. 또한 5개의 구멍(팬텀의 중심과 12시, 3시, 6시, 9시 방향)으로 구성된 CT head and body close phantom을 gantry aperture 내에 위치시키고 각 지점에서 선량을 측정하였다. Gantry apertue 내 피사체의 위치변화에 대한 영상의 노이즈를 비교하기 위해서 AAPM CT용 팬텀의 물통을 회전중심점과 12시 방향으로 5 cm와 10 cm 이동시킨 후 BC를 변화시키면서 스캔한 후 팬텀의 중심과 12시, 3시, 6시, 9시 방향의 지점에서 노이즈를 측정하였다. 이 중에서 몇 군데의 위치는 영상 영역에서 벗어나서 측정할 수가 없었다. 이대 노이즈 측정을 위해서 영상재구성의 슬라이스 두께는 5mm로 하였다. 측정한 결과 다음과 같은 결론을 얻었다: 첫째, CTDIw는 회전중심점으로부터 멀어질수록, BC가 넓어질수록 감소하였다. 둘째, BC의 넓이가 비슷한 경우는 CTDIw는 거의 유사한 값을 보였다. 즉, CTDIw는 검출기 배열의 수나 화소의 크기 보다는 전체적인 BC의 넓이에 의존하고 있음을 알 수 있었다. 셋째, air scan과 phantom scan 경우 모두에서 CTDIw는 BC가 증가될수록 감소하였다. 그러나 air scan의 경우보다 head pahntom scan 시 약 30%, body phantom scan 시 약 52% 정도 CTDIw의 값이 감소하였다. 넷째, BC와 팬텀의 위치 변화에 따른 노이즈 값은 2X0.5mm의 BC을 제외하고는 head pahntom scan한 경우 3.9~5.9, body phantom scan한 경우 5.3~7.4로 나타나, BC와 팬텀의 위치변화에 따라서 큰 차이가 없었다. 따라서 피사체의 위치가 gantry aperture 내 SFOV(scan field of view)에 포함될 경우 회전중심점에 정확하게 위치시키지 않아도 영상의 질에는 많은 영향을 미치지 않는다는 것을 알 수 있었다. The purpose of this study was to determine the dose distribution and image quality according to slice thichness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was palced at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the pahntom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrese as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector arry. The value of CTDIW decresed with increasing BC, but the value decreased 16.6~31.9% in the lead pahntom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC 2X0.5 mm regardless of the degree of deviation from the iso-center. When a subject was located within the SPOV, the position did not significantly affect image quality even if the subject was out of the center.

      • KCI등재

        의료분야 진단용방사선발생장치의 품질관리

        조평곤(Pyong-Kon, Cho) 한국방사선학회 2021 한국방사선학회 논문지 Vol.15 No.2

        진단용방사선발생장치를 이용한 검사는 영상의학과에서 인체 내 정보를 파악하기 위한 가장 유용한 진단장비 중 하나로 신뢰도가 매우 높다. 이와 같은 이유로, 최근에는 영상의학과 영역의 진단 검사 장비를 이용한 검사 건수가 매년 증가하고 있다. 또한, 검사 건수 증가는 장치의 빠른 노화를 불러일으키고 이로 인해 장치에 대한 정도관리(quality control, QC)의 중요성이 대두된다. 특히, 진단용방사선발생장치를 이용한 검사에서 정도관리란 검사시작부터 검사가 끝날 때 까지 발생할 수 있는 모든 문제점을 사전에 알아내고 대처하여 신뢰가 확보된 영상을 획득하여 제공하는 과정에 있는 일련의 모든 활동을 의미한다. 이에 본 연구에서는 진단용방사선발생장치를 이용한 검사에서 정도관리에 대해보고 한다. The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

      • KCI등재후보

        Head CT 검사 시 안구 차폐용 Bismuth사용에 의한 수정체 선량 감소에 대한 평가

        조평곤(Pyong-Kon Cho),김유현(You-Hyun Kim),최인자(In-Ja Choi),정정표(Jung-Pyo Chung),장상규(Sang-Gyu Chang),이현(Hyun Lee),김장섭(Jang-Seob Kim),신동철(Dong-Cheol Shin),최종학(Jong-Hak Choi),이기성(Ki-Sung Lee),이원호(Won-Ho Lee) 대한방사선과학회(구 대한방사선기술학회) 2008 방사선기술과학 Vol.31 No.2

          본 연구는 두부 전산화 단층촬영 시 차폐용 bismuth를 사용하여 수정체 선량의 감소와 차폐용 bismuth의 유용성을 평가하기 위해 수행되었다. 인체모형 팬텀과 열형광 선량계를 이용하여 (a) 안구를 포함한 두부 CT촬영 (b) 두부 전체가 포함된 CT촬영 (c) 안구를 배제하고 20°를 준 두부 CT촬영 시의 수정체 선량을 평가하였다. 수정체 선량의 감소효과는 안구를 포함한 두부 CT촬영에서 43.2%, 두부 전체가 포함된 CT촬영에서 36.0%, 20° 각도를 준 두부 CT촬영에서 1.4%로 나타나 두부 전체가 포함된 CT촬영과 안구를 포함한 두부 CT촬영에서는 상당한 감소효과가 있지만 안구를 제외한 20° 각도를 준 두부촬영에서는 감소효과가 적었다. 즉, 차폐용 bismuth를 사용한 수정체 선량감소는 안구가 촬영부위에 포함된 경우에는 유의한 것으로 나타났으나 안구가 포함되지 않은 두부 CT촬영일 경우에는 유의하지 않은 것으로 나타났다. 따라서 두부 CT촬영 시차폐용 bismuth의 사용은 안구가 포함되는 일부의 CT촬영에서만 제한적으로 사용되는 것이 바람직하다.   The aim of this study is to assess the dose reduction of eye lens and availability of bismuth garments resulting from the use of radioprotective bismuth garments to shield the eyes of patients undergoing head CT. Rando phantom and TLDs were used to determine the amount of dose reduction by bismuth shielding of the eye in the following simulated CT scans: (a) scanning of the head including orbits, (b) scanning of the whole head, and (c) 20° angled scanning of the head excluding orbits.<BR>  The average dose reduction of eye lens was 43.2%, 36.0% and 1.4% for the three CT scans listed above. Significant reduction in the eye lens dose was achieved by using superficial orbital bismuth shielding during head CT scans. However, bismuth shields should not be used for the patients when their eyes are excluded from the primarily exposed region.

      • KCI등재
      • KCI등재

        일반엑스선 검사 시 위치 잡이의 중요성

        조평곤(Pyong-Kon Cho) 대한방사선과학회(구 대한방사선기술학회) 2022 방사선기술과학 Vol.45 No.3

        The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

      • KCI등재

        뇌 컴퓨터단층검사 시 양자잡음제거 알고리즘을 적용한 영상의 비교평가

        조평곤(Cho Pyong-Kon) 대한방사선과학회(구 대한방사선기술학회) 2017 방사선기술과학 Vol.40 No.4

        본 연구의 목적은 뇌 컴퓨터단층검사 시 양자잡음제거(Quantum Denoising System; QDS) 알고리즘을 적용한 영상 분석을 통해 화질 향상 효과를 알아보고자 한다. 2017년 7월부터 2017년 10월까지 경북 소재 G 영상의학과에 뇌 컴퓨터단층검사를 위해 내원한 45명의 성인을 대상으로 동의하에 후향적 연구를 하였고, 뇌 컴퓨터단층검사 시 QDS(-)를 적용하지 않은 그룹(A Group)과 QDS(+)를 적용한 그룹(B Group)으로 나누어 검사하였다. 다음과 같은 결론을 얻었다. 노이즈값은 Pons부분과 Vermis부분 모두 QDS(+)를 적용한 B그룹에서 통계적으로 유의하게 낮았다(A Group; Pons 6.92±0.98HU, Vermis 6.72, B Group; Pons 5.41±1.05 HU, Vermis 5.28±0.73HU :p<0.05). SNR값은 Pons부분과 Vermis 부분 모두 QDS(+)를 적용한 B그룹에서 통계적으로 유의하게 높았다(A Group; Pons 5.21±1.28, Vermis 6.23±1.49, B Group; Pons 7.28±2.56, Vermis 8.63±3.04 : p<0.05). 결론적으로 뇌 컴퓨터단층검사 시 양자잡음제거 알고리즘을 적용한다면 영상의 노이즈 감소 및 신호 대 잡음비(SNR), 대조도 대 잡음비(CNR)를 좀 더 개선시켜 진단에 적절한 영상을 얻을 수 있을 것으로 생각된다. The objective of this study was to evaluate the enhancement effects of the quantum denoising system (QDS) on brain CT images. This retrospective study was conducted with 45 adults who visited G Radiology located in Gyungbuk for having brain CT tests between Jul 2017 and Oct 2017 after receiving consents. Subjects were divided into a control group (A group; no QDS(-) application during the brain CT test) and a treatment group (B Group; QDS(+) application during the brain CT test). The following conclusions were obtained from the study. The noise values at the Pons part and the Vermis part were significantly (p<0.05) lower in B Group (Pons=5.41±1.05 HU; Vermis=5.28±0.73HU) than A Group (Pons=6.92±0.98HU; Vermis=6.72). The SNR values at the Pons part and the Vermis part were significantly (p<0.05) higher in B Group (Pons=7.28±2.56; Vermis=8.63±3.04) than A Group (Pons=5.21±1.28; Vermis=6.23±1.49). In conclusion, the results of this study suggested that the application of QDS to the brain CT test would enhance the signal to noise ratio (SNR) and the contrast to noise ratio (CNR) to provide an image more appropriate for diagnosis.