http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
개정된 고등학교 화학 ll 교과서 실험 중에서 염소의 제법과 성질 실험의 비교 분석 및 개선
이광필,서현경,이무상,Lee, Kwang-Pill,Seo, Hyun-Kyung,Lee, Mu-Sang 대한화학회 2000 대한화학회지 Vol.44 No.1
The purpose of this study is to analyze comparatively and improve the preparation of chlorine gas in the high school chemistry II textbooks on the basis of the revised curriculum. From the results of the preparation experiment of chlorine gas which is commonly dealing with 9 kinds of textbook in the nation, we have found some problems and have suggested the solution of these problems. The problem is the students may inhale the chlorine gas that is to be injurious on the human body, so the research is focused on safe experimental method without inhalation of chlorine gas. The simple conviction method of character in laboratory is to propose at 5 kinds. 본 연구는 제 6차 교육과정에 의거하여 개정된 고등학교 화학 II 교과서 실험 중에서 염소의 제법과 성질 실험에 대한 비교 분석 및 개선에 목적을 두고 있다. 국내 9종 교과서에서 다루고 있는 염소 기체의 발생 실험을 수행하여 문제점을 발견하고 최적의 실험 방법을 제시한다. 염소 기체의 발생 실험에서 가장 큰 문제점은 인체에 해로운 염소 기체를 학생들이 흡임할 수 있다는 것이므로 염소 기체를 흡입하지 않고 안전하게 실험하는 것에 중점을 두었다. 실험실에서 간단하고 쉽게 관찰할 수 있는 염소 기체의 성질 확인 방법도 5가지로 정리해서 제시한다.
고성능 액체 크로마토그래피에 의한 기능성 헤테로고리화합물의 분리(I)
이광필,조윤진,이영철,Lee, Kwang-PilI,Cho, Yun Jin,Lee, Young Cheol 한국분석과학회 1997 분석과학 Vol.10 No.6
기능성 헤테로 고리 화합물의 구조 이성질체를 정상 및 역상 액체 크로마토그래피를 이용하여 분리하고, 이들 분리를 위한 최적 조건을 알코올 변형체(modifier)를 포함한 삼성분 이동상(ternary solvent system)을 이용하여 조사했다. 삼성분 이동상의 경우 알코올 변형체가 컬럼의 활성 표면에 우선적으로 상호작용하여 비활성화(deactivation)시킴으로써 용질의 머무름을 감소시키고 꼬리 끌림(tailing)을 억제하여 분리선택성이 좋아지는 것으로 보인다. 구조 이성질체 분리의 경우 정상 액체 크로마토그래피를 이용할 경우가 분리 선택성이 더 좋은 것으로 나타났다. 또한, 헤테로 고리 화합물들의 머무름 거동은 역상 액체 크로마토그래피의 경우는 시료와 정지상과의 소수성 상호작용등으로 설명할 수 있었고, 정상 액체 크로마토그래피의 경우는 시료 분자와 충진제의 흡착표면과의 흡착력으로 설명할 수 있었다. Normal phase or reversed phase liquid chromatographic separation of some structural isomers of functionalized heterocyclic compounds has been carried out by using several different columns and various mobile phases. The optimal experimental conditions for separation of structural isomers were found on a ternary solvent system including alcohol as a modifier. This polar modifier is preferentially adsorbed onto strong adsorption site, leaving a more uniform population of weaker site that then serve to retain the sample. This 'deactivation' of the adsorbent leads to a number of improvements in subsequent separations. The optimal mobile phase system of separation were found on normal phase on structural isomers. Retention mechanism of normal phase system was also studied depending on adsorption strength between solute and stationary phase of column. However, retention factors of reversed phase system were found on hydrophobic interaction with solvophobic effect.
$n/{\gamma}$ 복합 방사선장에서의 중성자 스펙트럼 분리 측정연구(1)
이광필,김원식,Lee, Kwang-Pill,Kim, Wuon-Shik 한국분석과학회 1993 분석과학 Vol.6 No.5
$^{241}Am-Be$(${\alpha}$, n) 중성자 선원의 중성자/감마선(n/${\gamma}$) 복합 방사선장에서 $^6Li$(n, ${\alpha}$)T 핵반응을 이용하고 두 섬광체, BC 501($C_8H_{10}$)과 Cerium의 섬광 감쇠 시간차와 동일 섬광체 내에서의 n/${\gamma}$에 대한 서로 다른 섬광감쇠 시간차를 병용하여 PSD(Pulse Shape Disciminator) 및 CFD(Constant Fraction Discriminator) 방법으로 n와 ${\gamma}$성분을 분리 측정하였으며 $^6Li$ 속중성자 분광계의 figure of merit는 1.36으로 평가되었다. In n/${\gamma}$ mixed field of $^{241}Am-Be$(${\alpha}$, n) neutron source, we seperated the neutron component from gamma ray component. At the center of the detector, $^6Li$ was doped on the cerium activated glass plate for $^6Li$(${\alpha}$, n)T nuclear reaction. The time differences of the light following excitations by different scintillators, BC501($C_8H_{10}$) and cerium, and by the same scintillator for different radiations as neutrons and gamma-rays are used to apply the methods of PSD(Pulse Shape Discriminator) and CFD(Constant Fraction Discriminator). The figure of merit of $^6Li$ fast neutron spectrometer is estimated as 1.36.