      • 원주의료기기산업 클러스터의 형성과정에 관한 연구

        이우천,윤형로,Lee, Woo-Chun,Yoon, Hyung-Ro 산업클러스터학회 2007 산업클러스터 Vol.1 No.1

        Wonju Medical Equipment Industry, despite of its short history, poor sales and weak manpower and so on, have shown remarkable outcomes in a relatively short period. At the end of 2007, totally 79 enterprises (only 4.6% of whole enterprises in Korea) made 10% of the nationwide production and 15% of the nationwide exports with an annual average growth rate of 66.7%, contributing domestic medical equipment industry tremendously. In addition, many leading medical equipment enterprises in various fields already moved or plan to move to Wonju, accelerating Wonju Medical Equipment Cluster. Wonju Medical Equipment Industry Cluster now enters into the growth stage, getting out of the initial business setup stage. Especially, the nomination of Wonju cluster project from the government accelerates networking (e.g. the development of the universal parts, the establishment of the mutual collaboration model among enterprises, and the mutual marketing), making a rapid growth in Wonju Medical Equipment Industry. Wonju Medical Equipment Industry Cluster revealed positive outcomes despite of the weakness in investment size and infra-structure comparing with the other medical industry cluster in the advanced country, while many domestic enterprises pursued their own growth models and thus failed to promote the international competitive power. Wonju Medical Equipment Industry has been developed rapidly. However, there are many challenging problems to support enterprises: small R&D investment and thus weak technology power, difficulties in recruiting R&D engineers, and poor marketing capabilities, financial infrastructure & policies, and network architecture. In order to develop a world-competitive medical equipment industry cluster at Wonju, the complement of infrastructures, the technology innovation, the mutual marketing, and the network expansion to support enterprises are further required. Wonju' s experiences in developing medical equipment industry so far suggest that our own flexible cluster model considering the industry structure and maturity for different regions should be developed, and specific action plans from the local and central governments based on their systematic strategies for industry development should be implemented in order to build world-competitive industry clusters in Korea.

      • KCI등재후보

        Resonace theory에 기반을 둔 index function을 통한 새로운 QRS 검출 알고리즘

        이전,윤형로,이경중,Lee, Jeon,Yoon, Hyung-Ro,Lee, Kyung-Joong 대한의용생체공학회 2003 의공학회지 Vol.24 No.2

        본 연구는 공진이론에 기초한 인덱스 함수(index function)를 이용하여 간단하게 QRS를 검출하는 새로운 알고리즘에 관한 것이다 ECG 근 몇 개의 사인파형의 조합으로 모델링 가능하며. 이때 ECG의 일차차분 값은 사인파형의 크기 및 주파수와 관계가 있다. 이 사실에 근거하여, R-L-C 회로의 허수부의 제곱값과 유사한 인덱스함수를 디자인하였으며. 인덱스 함수의 응답에 적응방법(adaptive method)를 첨가하여 QRS를 검출하였다. 이 알고리즘은 다른 QRS 검출 알고리즘에 비해 비슷하거나 높은 검출성능을 보였고. 복잡한 전처리 또는 후처리 과정이 필요치 않으므로 실시간 검출에 유용하게 사용될 수 있을 것이다. This paper describes a new simple QRS detection algorithm using index function based on resonance theory. The ECG signal can be modeled with several sinusoidal pulses and its first difference has some relations with the amplitude and frequency of sinusoidal pulse. Based on above fact, an index function, similar to the square of the imaginary part of a simple R-L-C circuit, was designed. A QRS complex is detected by applying the adaptive method to the response of index function. The algorithm showed a performance comparable to or higher than the other algorithms. Because it does not require any complicated preprocessing or postprocessing, it can be implemented in real time.

      • KCI등재

        각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정

        김덕원,류창용,윤형로,Kim, Deok-Won,Ryu, Chang-Yong,Yoon, Hyung-Ro 대한의용생체공학회 1995 의공학회지 Vol.16 No.2

        대기오염, 수질오염, 소음공해 등은 국내에서도 널리 알려지고 이에 대한 연구와 대책들이 수행되고 있으나 전자파 공해에 대한 인식은 국내에서는 매우 단편적이며 이에 대한 기초 연구조차 되어 있지 않아 국민 보건을 위해서 이 분야에 대한 연구가 시급한 실정이다. 그리하여 본 연구에서는 각종 가정용, 사무용 및 통신용 전기기기에서 발생하는 전자파를 측정하였고 또한 전철역 및 변전소 등에서와 같이 전자파가 많이 발생하는 장소에서도 측정하였다. 측정결과, 가정용 전기기기의 경우 전자레이니가 많은 양의 자계와 microwave를 방출하고 전기요의 경우에도 많은 양의 자계가 발생하였으며, 또한 청소년들이 많이 이용하는 전자오락실의 경우도 많은 자계가 발생하여 이에 대한 규제 및 대책이 시급한 것으로 나타났다. 요즈음 문제가 되고 있는 휴대용 전화기 및 car-phone의 경우도 위험하다고 추정되는 기준치에 비해 거의 십여배에 해당되는 micorwave가 검출되어 휴대용 전화기 및 car-phone의 사용자가 급격히 늘어가는 추세에 비추어 이에 대한 대책이 시급한 실정이다. 그리고 많은 시민들이 이용하는 지하철 및 지하철 역의 경우, 특히 국철 전돛차에서 많은 양의 자계가, 국철역에서는 많은 양의 자계 및 전계가 측정되었다. 본 연구에서는 각종 전기기기 및 장소에 따른 전자파를 측정하여서 data-base를 구축하였고 이를 통하여 앞으로의 역학 조사 및 연구에 발판을 마련하고자 한다. Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

      • KCI등재

        비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법

        김응석,노연식,서광석,박성빈,윤형로,Kim, Eung-Seok,Noh, Yeon-Sik,Seo, Kwang-Seok,Park, Sung-Bin,Yoon, Hyung-Ro 대한의용생체공학회 2010 의공학회지 Vol.31 No.5

        The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

      • KCI등재

        자세변화에 따른 PWV 변화량의 평가

        전석환,정인철,정상오,윤형로,Jun, Suk-Hwan,Jeong, In-Cheol,Jung, Sang-O,Yoon, Hyung-Ro 대한의용생체공학회 2009 의공학회지 Vol.30 No.2

        The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

      • SCOPUSKCI등재
      • SCOPUSKCI등재
      • 지능형 바이오피드백 기반의 종합 운동관리 시스템 개발

        유성재(Yoo Sung-Jae),노연식(Noh Yeon-Sik),남영광(Nam Young-Kwang),윤형로(Yoon Hyung-Ro) 한국정보과학회 2011 한국정보과학회 학술발표논문집 Vol.38 No.1B

        건강에 대한 관심이 높아지면서 헬스케어와 IT와의 결합으로 많은 IT관련 헬스 케어 시스템이 개발되고 있으며, 이러한 시스템의 수요 또한 증가하는 추세에 있다. 본 논문에서는 이와 같은 건강에 대한 관심을 반영하여 자신에 맞는 운동을 선택 및 수행하고 그에 따른 피드백을 받을 수 있는 시스템을 소개한다. 본 시스템은 헬스케어의 건강 관리 시스템을 피트니스 관점에 비중을 두어 이용자의 초기 운동 정보를 기반으로 몸에 맞는 운동을 처방하여 운동을 수행 시키고 그 결과를 저장한다. 운동 정보는 생체 신호 계측을 위한 물리량 센서 및 모듈에 의하여 측정된다. 저장된 운동 결과는 다음 운동 처방에 반영되어 피드백 방식으로 이용자의 운동에 적용된다. 운동 처방은 주단위로 수행되면서 지속적인 관리를 받을 수 있도록 설계되었다. 본 시스템은 운동 중 발생하는 무구속, 무자각적 생체 신호 계측을 위한 물리량 센서 및 모듈을 이용하여 다차원 생체 정보를 수집하고 생체 신호 표준화 및 생체 역학적 해석을 통해 데이터베이스를 구축하였다. 이렇게 구축한 데이터들을 통하여 지능형 바이오피드백 기반의 사용자 맞춤형 운동 관리 시스템을 개발하여 사용자의 건강 및 운동능력을 향상시키는데 그 목적이 있다.