http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
( Mitsuo Yoshida ) 한국폐기물자원순환학회(구 한국폐기물학회) 2015 한국폐기물자원순환학회 3RINCs초록집 Vol.2015 No.-
In order to improve the environmental state of municipal solid waste dump site located in semi-arid land of Mashhad, north eastern part of Iran, leachate recirculation method was applied. The leachate recirculation was successfully isolated the leachate flows within the dump site and enhancement of gas production ability was observed.
Vibration Minimized Design of Trapezoidal Acceleration Input for Semiconductor Manufacturing Systems
Mitsuo Hirata,Tomohiro Harayama,Kouji Yoshida,Youzou Fukagawa 제어로봇시스템학회 2009 제어로봇시스템학회 국제학술대회 논문집 Vol.2009 No.8
In this paper, we discuss about the design of the trapezoidal acceleration input which does not excite the mechanical vibration modes. We first obtain the spectrum of the trapezoidal acceleration input analytically, and the frequencies where the spectrum becomes zero are obtained. Since the zero spectrum frequencies are the function of the ramp-up and ramp-down time, they can be determined so as to coincide with the resonance frequencies of the mechanical vibration modes. The effectiveness of the proposed method is evaluated by simulations. The proposed method is very simple, and it is easy to apply not only to the stepper for semiconductor manufacturing systems but also to any other industrial systems that use trapezoidal acceleration input.
Naohisa Yoshida,Osamu Dohi,Ken Inoue,Ritsu Yasuda,Takaaki Murakami,Ryohei Hirose,Ken Inoue,Yuji Naito,Yutaka Inada,Kiyoshi Ogiso,Yukiko Morinaga,Mitsuo Kishimoto,Rafiz Abdul Rani,Yoshito Itoh 거트앤리버 소화기연관학회협의회 2019 Gut and Liver Vol.13 No.2
A laser endoscopy system was developed in 2012. The system allows blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI) to be performed as modes of narrowband light observation; these modes have been reported to be useful for tumor detection and characterization. Furthermore, an innovative endoscopy system using four-light emitting diode (LED) multilight technology was released in 2016 to 2017 in some areas in which laser endoscopes have not been approved for use, including the United States and Europe. This system enables blue light imaging (this is also known as BLI) and LCI with an LED light source instead of a laser light source. Several reports have shown that these modes have improved tumor detection. In this paper, we review the efficacy of BLI and LCI with laser and LED endoscopes in tumor detection and characterization.