http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
데이터기반 설계관리 프로세스 적용을 위한 설계시스템 발주요건 개발
김우중(Woojung Kim),변수진(Soojin Byon),류동수(Dongsoo Ryu) (사)한국CDE학회 2013 한국 CAD/CAM 학회 학술발표회 논문집 Vol.2013 No.1
Korean nuclear power plants in the UAE as a base for exporting nuclear power plants, research on international competitiveness has emerged as a significant challenge. The advancement of the design and management is the core of the global technology ompetitiveness Domestic nuclear power plants that perform document-centric design, data base and 3D CAD-based design of data-based switching is required. As a result management processes are required to develop a data-driven design. In this study, analyze the design management requirements that changes in the data-driven design process and a new nuclear power plant in Europe. The Suggestions of This Study is Data-based design system requirements development schemes.
대장내시경 전처치로 Picosulfate Sodium/Magnesium Citrate 사용 후 발생한 혼수를 동반한 급성 저나트륨혈증 1예
김우중 ( Woojung Kim ),박상영 ( Sang Young Park ),김미정 ( Mi Jeoung Kim ),구향모 ( Hyang Mo Koo ) 대한내과학회 2016 대한내과학회지 Vol.91 No.2
결론적으로, PS/MC는 효과적인 대장내시경 전처치제이나 장점막에 미세한 염증반응을 일으키거나, 삼투 효과에 의한 장점막에서의 수분과 전해질의 이동, 메스꺼움 등 비삼투성자극을 통한 ADH 과분비를 유발함으로써 저나트륨혈증 등의 전해질 불균형이 발생할 수 있다. 따라서 고령, 갑상선기능저하증, 기저 심장/신장/간질환이 있는 환자에게 처방시 특별한 주의가 요구되며, 갑작스러운 혈장량의 감소가 발생하지 않도록 전처치시 적절한 수분섭취를 교육하는 것이 중요하다. 그러나 비교적 맛과 용량 면에서 순응도가 높은 하제임에도 PS/MC가 위팽만이나 구역, 구토를 유발할 수 있고 항진된 장운동 자체도 비삼투성 자극체로서 ADH를 상당 수준과발현시켜 의식 소실이나 신경학적 이상을 유발할 정도의 심각한 저나트륨혈증이 발생할 수 있으며, 이것이 탈수나 기타 위험 인자가 없는 상황에서도 충분히 합병될 수 있음을 의료진이 인지하여, 3% 고장성 식염수나 항경련제 등의 치료가 시기적절하게 진행될 수 있도록 하는 것이 중요하겠다. Picosulfate sodium/Magnesium citrate (PS/MC) is a common bowel cleansing agent for colonoscopy. It is equally effective and better tolerated by patients with regard to taste and volume than polyethylene glycol. However, because of its osmotically active characteristics, PS/MC can cause plasma volume depletion and electrolyte disturbances, such as hyponatremia. Here, we report a case of severe hyponatremia combined with loss of consciousness in a 59-year-old woman following ingestion of PS/MC as bowel preparation for a screening colonoscopy. Upon arrival, serum sodium level was 109 mEq/L and urine osmolality and sodium levels were 393 mOms/Kg and 99 mmol/L, respectively. She was euvolemic and showed normal kidney, thyroid, and adrenal function. Based on these findings, inappropriate anti-diuretic hormone syndrome (SIADH) was diagnosed. She was treated with 3% hypertonic saline and completely recovered without any neurologic sequelae. This case shows that SIADH can be caused by PS/MC (not accompanied by dehydration), even in patients without any underlying renal, heart, or liver diseases. (Korean J Med 2016;91:206-210)
김우중(Woojung Kim),임현주(Hyunjoo Lim),차한주(Hanju Cha) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
본 논문에서는 매트릭스 컨버터의 입력 필터를 설계하고 실험을 수행한 후 입력 파형 비교를 통하여 타당성을 검증하고 분석한다. 매트릭스 컨버터는 18개의 양방향 스위치로 구성되어 있으며, 출력 전압을 합성하기 위해 각각의 스위치가 실시간으로 빠르게 온-오프 한다. 이러한 스위칭 과정에서 고차 고조 파가 발생하고, 이 고조파는 매트릭스 컨버터 주위에 연결된 각종 기기에 영향을 미친다. 이러한 영향을 줄이기 위해 설치한 것이 입력필터이다. 본 논문에서는 적절한 입력필터의 소자값을 계산해 내는 과정을 설명하고 이를 구현한 후, 실험을 통해 필터의 설치 전후의 입력 전류 고조파 왜곡율(THD) 등 파형의 변화를 비교하여 설계 값의 타당성과 필터의 적정성을 알아본다.