RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Determining the age of cats by pulp cavity/tooth width ratio using dental radiography

        Kyoungsun Park,Jaesang Ahn,Sunmee Kang,Euiri Lee,김수현,박상완,Sungwon Park,Hyunwoo Noh,서강문 대한수의학회 2014 JOURNAL OF VETERINARY SCIENCE Vol.15 No.4

        The purpose of this study was to evaluate the effect of age onthe ratio of pulp cavity/tooth width (P/T ratio) in healthycats. The dental radiographs of 32 cats (16 males and 16females) were generated with a digital dental X-ray unit withthe animals under general anesthesia. Standardizedmeasurement of the canine teeth was performed by drawinga line on the radiograph perpendicular to the cementoenameljunction (CEJ) of the tooth. There was an inverselyproportional correlation between chronological age and theP/T ratio. Moreover, a strong Pearson squared correlation(γ2 = 0.92) was identified by the curved regression model. Nosignificant differences in the P/T ratio based on gender orbreed were found. These results suggest that determinationof age by P/T ratio could be clinically useful for estimating the chronological age of cats.

      • KCI등재후보

        Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

        Lokade, Joyti,Rawlani, Shivlal,Baheti, Rakhi (Chandak),Roy, Shelly,Chandak, Manoj,Lohe, Vidya Korean Academy of Dental Science 2011 Journal of korean dental science Vol.4 No.1

        Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

      • Bortezomib Facilitates Reparative Dentin Formation after Pulp Access Cavity Preparation in Mouse Molar

        Jung, Jae-Kwang,Gwon, Gi-Jeong,Neupane, Sanjiv,Sohn, Wern-Joo,Kim, Ki-Rim,Kim, Ji-Youn,An, Seo-Young,Kwon, Tae-Yub,An, Chang-Hyeon,Lee, Youngkyun,Kim, Jae-Young,Ha, Jung-Hong Elsevier 2017 JOURNAL OF ENDODONTICS - Vol.43 No.12

        <P><B>Abstract</B></P> <P><B>Introduction</B></P> <P>The aim of this study was to evaluate <I>in vitro</I> and <I>ex vivo</I> roles of bortezomib, a proteasome inhibitor that binds to the active site of the 26S proteasome, in tertiary dentin formation.</P> <P><B>Methods</B></P> <P>We established pulpal access cavity preparation that was treated with or without bortezomib before direct pulp capping with a calcium hydroxide–based material. We also analyzed bone morphogenetic protein (Bmp)- and Wnt-related signaling molecules using quantitative real-time polymerase chain reaction.</P> <P><B>Results</B></P> <P>In the short-term observation period, the bortezomib-treated pulp specimens showed the period-altered immunolocalization patterns of nestin, CD31, and myeloperoxidase, whereas the control specimens did not. The bortezomib-treated group showed a complete dentin bridge with very few irregular tubules after 42 days. The micro–computed tomographic images showed more apparent dentin bridge structures in the treated specimens than were in the controls. Quantitative real-time polymerase chain reaction analysis showed up-regulated Bmp and Wnt.</P> <P><B>Conclusions</B></P> <P>These findings revealed that treatment with 1 μmol/L bortezomib induced reparative dentin formation that facilitated the maintenance of the integrity of the remaining pulpal tissue via early vascularization and regulation of Bmp and Wnt signaling.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Bortezomib facilitates reparative dentin formation through modulated vascularization and inflammatory response. </LI> <LI> Molecular mechanisms underlying bortezomib treatment would be related with Bmp and Wnt signaling. </LI> <LI> Pulpal access cavity preparation using a mice model system permits us to evaluate a range of drugs for their ability of reparative dentin formation. </LI> </UL> </P>

      • KCI등재

        Comparison of dental radiography and computed tomography: measurement of dentoalveolar structures in healthy, small-sized dogs and cats

        Seunghee Lee,Kichang Lee,Hyeona Kim,Jeongsu An,Junho Han,Taekwon Lee,Hogyun Jeong,Youngkwon Cho 대한수의학회 2020 Journal of Veterinary Science Vol.21 No.5

        Background: Dental diseases are common in dogs and cats, and accurate measurements of dentoalveolar structure are important for planning of treatment. The information that the comparison computed tomography (CT) with dental radiography (DTR) is not yet reported in veterinary medicine. Objectives: The purpose of this study was to compare the DTR with CT of dentoalveolar structures in healthy dogs and cats, and to evaluate the CT images of 2 different slice thicknesses (0.5 and 1.0 mm). Methods: We included 6 dogs (2 Maltese and 1 Spitz, Beagle, Pomeranian, mixed, 1 to 8 years, 4 castrated males, and 2 spayed female) and 6 cats (6 domestic short hair, 8 months to 3 years, 4 castrated male, and 2 spayed female) in this study. We measured the pulp cavity to tooth width ratio (P/T ratio) and periodontal space of maxillary and mandibular canine teeth, maxillary fourth premolar, mandibular first molar, maxillary third premolar and mandibular fourth premolar. Results: P/T ratio and periodontal space in the overall dentition of both dogs and cats were smaller in DTR compared to CT. In addition, CT images at 1.0 mm slice thickness was generally measured to be greater than the images at 0.5 mm slice thickness. Conclusions: The results indicate that CT with thin slice thickness provides more accurate information on the dentoalveolar structures. Additional DTR, therefore, may not be required for evaluating dental structure in small-sized dogs and cats.

      • KCI등재

        In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

        Tampelini, Fernanda Garcia,Coelho, Marcelo Santos,de Azevedo Rios, Marcos,Fontana, Carlos Eduardo,Rocha, Daniel Guimaraes Pedro,Pinheiro, Sergio Luiz,da Silveira Bueno, Carlos Eduardo The Korean Academy of Conservative Dentistry 2017 Restorative Dentistry & Endodontics Vol.42 No.3

        Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

      • KCI등재

        In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

        Fernanda Garcia Tampelini,Marcelo Santos Coelho,Marcos de Azevêdo Rios,Carlos Eduardo Fontana,Daniel Guimarães Pedro Rocha,Sergio Luiz Pinheiro,Carlos Eduardo da Silveira Bueno 대한치과보존학회 2017 Restorative Dentistry & Endodontics Vol.42 No.3

        Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a × 25 magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

      • KCI등재

        Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals

        Tavares Karina Ines Medina Carita,Pinto Jáder Camilo,Santos-Junior Airton Oliveira,Esteves Torres Fernanda Ferrari,Guerreiro-Tanomaru Juliane Maria,Tanomaru-Filho Mario 대한치과보존학회 2021 Restorative Dentistry & Endodontics Vol.46 No.4

        Objectives This study evaluated 2 nickel-titanium rotary systems and a complementary protocol with an ultrasonic tip and a small-diameter instrument in flattened root canals. Materials and Methods Thirty-two human maxillary second premolars with flattened canals (buccolingual diameter ≥4 times larger than the mesiodistal diameter) at 9 mm from the radiographic apex were selected. The root canals were prepared by ProDesign Logic (PDL) 30/0.01 and 30/0.05 or Hyflex EDM (HEDM) 10/0.05 and 25/0.08 (n = 16), followed by application of the Flatsonic ultrasonic tip in the cervical and middle thirds and a PDL 25/0.03 file in the apical third (FPDL). The teeth were scanned using micro-computed tomography before and after the procedures. The percentage of volume increase, debris, and uninstrumented surface area were analyzed using the Kruskal-Wallis, Dunn, Wilcoxon, analysis of variance/Tukey, and paired and unpaired t-tests (α = 0.05). Results No significant difference was found in the volume increase and uninstrumented surface area between PDL and HEDM (p > 0.05). PDL had a higher percentage of debris than HEDM in the middle and apical thirds (p < 0.05). The FPDL protocol resulted in less debris and uninstrumented surface area for PDL and HEDM (p < 0.05). This protocol, with HEDM, reduced debris in the middle and apical thirds and uninstrumented surface area in the apical third (p < 0.05). Conclusions High percentages of debris and uninstrumented surface area were observed after preparation of flattened root canals. The HEDM, Flatsonic tip, and 25/0.03 instrument protocol enhanced cleaning in flattened root canals.

      • KCI등재

        The effectiveness of the supplementary use of the XP-endo Finisher on bacteria content reduction: a systematic review and meta-analysis

        Oliveira Ludmila Smith de Jesus,Bragança Rafaella Mariana Fontes de,Sarkis-Onofre Rafael,Faria-e-Silva André Luis 대한치과보존학회 2021 Restorative Dentistry & Endodontics Vol.46 No.3

        Objectives: This systematic review evaluated the efficacy of the supplementary use of the XP-endo Finisher on bacteria content reduction in the root canal system. Materials and Methods: In-vitro studies evaluating the use of the XP-endo Finisher on bacteria content were searched in four databases in July 2020. Two authors independently screened the studies for eligibility. Data were extracted, and risk of bias was assessed. Data were meta-analyzed by using random-effects model to compare the effect of the supplementary use (experimental) or not (control) of the XP-endo Finisher on bacteria counting reduction, and results from different endodontic protocols were combined. Four studies met the inclusion criteria while 1 study was excluded from the meta-analysis due to its high risk of bias and outlier data. The 3 studies that made it to the meta-analysis had an unclear risk of bias for at least one criterion. Results: No heterogeneity was observed among the results of the studies included in the meta-analysis. The study excluded from the meta-analysis assessing the bacteria counting deep in the dentin demonstrated further bacteria reduction upon the use of the XP-endo Finisher. Conclusions: This systematic review found no evidence supporting the supplementary use of the XP-endo Finisher on further bacteria counting the reduction in the root canal.

      • KCI등재

        Evaluation of mesial root canal configuration of mandibular first molars using micro-computed tomography

        Altan Şallı Gülay,Egil Edibe 대한영상치의학회 2021 Imaging Science in Dentistry Vol.51 No.4

        Purpose: The aim of this study was to evaluate the root canal morphology of mesial roots of mandibular first molars. Materials and Methods: Forty extracted mandibular first molars were used in this study. The morphological examination of root canals was conducted in accordance with the Vertucci classification using micro-computed tomography (micro-CT). Any aberrant root canal configurations not included in the Vertucci classification were recorded, and their frequency was established using descriptive statistics. Intra-observer reliability was assessed using the Wilcoxon signed-rank test, while inter-observer reliability was assessed using the Cohen kappa test. Significance was evaluated at the P<0.05 level. Results: The mesial roots of mandibular first molars had canal configurations of type I (15%), type II (7.5%), type III (25%), type IV (10%), type V (2.5%), type VI (7.5%), and type VII (7.5%). The images showed 10 (25%) additional configuration types that were not included in the Vertucci classification. These types were 1-3-2-3, 1-2- 3-2-3, 2-3-1, 2-3, 1-2-3-1, 2-1-2-3, 3-2-1, 1-2-3-1, 2-3-2-3, and 1-2-1-2-1. The intra-observer differences were not statistically significant (P>0.05) and the kappa value for inter-observer agreement was found to be 0.957. Conclusion: Frequent variations were detected in mesial roots of mandibular first molars. Clinicians should take into consideration the complex structure of the root canal morphology before commencing root canal treatment procedures to prevent iatrogenic complications. Micro-CT was a highly suitable method to provide accurate 3-dimensional visualizations of root canal morphology.

      • SCOPUSKCI등재

        Evaluation of mesial root canal configuration of mandibular first molars using micro-computed tomography

        Salli, Gulay Altan,Egil, Edibe Korean Academy of Oral and Maxillofacial Radiology 2021 Imaging Science in Dentistry Vol.51 No.-

        Purpose: The aim of this study was to evaluate the root canal morphology of mesial roots of mandibular first molars. Materials and Methods: Forty extracted mandibular first molars were used in this study. The morphological examination of root canals was conducted in accordance with the Vertucci classification using micro-computed tomography (micro-CT). Any aberrant root canal configurations not included in the Vertucci classification were recorded, and their frequency was established using descriptive statistics. Intra-observer reliability was assessed using the Wilcoxon signed-rank test, while inter-observer reliability was assessed using the Cohen kappa test. Significance was evaluated at the P<0.05 level. Results: The mesial roots of mandibular first molars had canal configurations of type I (15%), type II (7.5%), type III (25%), type IV (10%), type V (2.5%), type VI (7.5%), and type VII (7.5%). The images showed 10 (25%) additional configuration types that were not included in the Vertucci classification. These types were 1-3-2-3, 1-2-3-2-3, 2-3-1, 2-3, 1-2-3-1, 2-1-2-3, 3-2-1, 1-2-3-1, 2-3-2-3, and 1-2-1-2-1. The intra-observer differences were not statistically significant(P>0.05) and the kappa value for inter-observer agreement was found to be 0.957. Conclusion: Frequent variations were detected in mesial roots of mandibular first molars. Clinicians should take into consideration the complex structure of the root canal morphology before commencing root canal treatment procedures to prevent iatrogenic complications. Micro-CT was a highly suitable method to provide accurate 3-dimensional visualizations of root canal morphology.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼