RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI우수등재

        경기북부 산업단지 주변 농지의 토양오염도 조사연구

        박진호(Jin-Ho Park),권경안(Kyung-Ahn Kwon),정은희(Eun-Hee Jung),김재광(Jae-Kwang Kim),김지영(Ji-Young Kim),오조교(Jo-Kyo Oh) 한국환경보건학회 2017 한국환경보건학회지 Vol.43 No.5

        This study was investigated on pH, heavy metals, oils and solvents in 34 surface soil samples and the samples are collected at two times for 17 farmland sites around 7 industrial areas in Northern Gyeonggi Province. As a result of pH for soil contamination monitoring network, the range of pH showed 4.4~8.4 and average was 6.3. The range of pH for Agricultural land around industrial area was 6.7~7.5 and average indicated 7.1 that mostly showed neutral condition in this area. he average concentrations of Cu, Pb, Ni, As and Cr are lower than Korea soil contamination worrisome levels at region 1 and the mean levels of farmland from the soil quality monitoring network. The average concentrations of Zn, Cd and Hg didn’t exceed the soil contamination worrisome levels at region 1 but slightly higher than the mean levels of farmland from the soil quality monitoring network. The heavy metal levels of all samples are within Korea soil contamination worrisome levels at region 1. The results showed that the detected heavy metal concentrations ranged from N.D. to ~32.7% of Korea soil contamination worrisome levels at region 1. BTEX, TPH, TCE and PCE were not detected in all samples and thus the farmland around the industrial areas were free from oils and solvents contamination.

      • KCI등재

        소화기 사격장의 중금속 오염 양상

        이광렬,현재혁,Lee, Kwang-Lyeol,Hyun, Jae-Hyuk 한국지하수토양환경학회 2016 지하수토양환경 Vol.21 No.3

        The study examined the level of heavy metal contamination by dividing military rifle shooting ranges into the three areas, i.e firing, trajectory, and target. The target area was found to be contaminated at a level higher (Cu 845 mg/kg, Pb 30,487 mg/kg) than the Worrisome Level of Soil Contamination (hereinafter referred to as the “Worrisome Level”) The trajectory area was predicted to be free from contamination, but it did indicate contamination although it was pretty much lower (Cu 23 mg/kg, Pb 99 mg/kg) than Worrisome Level. This is attributed to the contamination spread when rearranging the soil of the target area during the maintenance of the shooting range. The firing area was also predicted to be free from heavy metal contamination, but the results analyzed indicated a contamination higher (Cu 201 mg/kg, Pb 2,286 mg/kg) than Worrisome Level. This is attributed to the fragments of the broken bullet scattering due to the pressure generated as the bullet leaves the muzzle. An examination of heavy metal contamination in the discharge area as well as gutters to prevent the intrusion of rain water from perimeter revealed a high level of contamination (Cu 298 mg/kg, Pb 6,497 mg/kg), which makes it necessary to take measures.

      • 일반촬영실 납마커의 오염인식도 및 오염도에 관한 연구

        이상준(Sang-Joon Lee),신재익(Jae-Ik Shin),어기상(Gi-Sang Eo),김종익(Jong-Ik Kim) 대한영상의학기술학회 2016 대한영상의학기술학회 논문지 Vol.2016 No.1

        Purpose : The study aims to investigate how frequently lead markers are used to indicate a patient position in a general radiographic inspection, how much aware clinical radiographers are of the contamination of lead markers, and what the actual contamination situations are like. Participants and Methods : The study included 249 radiographers across the country who were in practice between 2 May 2015 and 2 November 2015. As for study methods, firstly, a survey consisting of a total of 13 questions was carried out regarding a frequency of use of lead markers and an awareness of contamination. For a reliance analysis of the survey into the frequency of use of lead markers and the awareness of contamination, a Cronbach alpha value was calculated using the SPSS Ver.23. Secondly, in order to identify a level of contamination of lead markers, a method using an adhesive cotton plaster that showd a highest response rate in the survey as a material used to fix and attach lead markers and a method using a gel pad that is reusable after wash and currently being used in our clinic were adopted. Each of an adhesive cotton plaster and a gel pad method was used for a day, and they were checked for germiculture after the 24 hours cultivation. Thirdly, in order to identify a contamination level of a reusable gel pad, a gel pad lead marker that was used for a day was cleaned with a microshield handwash and checked for germiculture. Result : In the survey about a frequency of use of lead markers, 60% answered that they were using lead markers, with 78% saying that they were using markers as a manual insertion method using a program of the device itself, 70% answering that they were doing an auto-marking using a program of the device itself, 70% replying that lead markers were needed to indicate a patient position, 80% answering that using lead markers could reduce errors in patient position information, and 88% agreeing to the survey that lead markers needed to be used together with program markers. In the survey about the awareness of contamination in the use of lead markers, 50% responded yes to the question lead markers might be clean , 75% to there might be some germs , 70% to there are concerns of contamination , 50% to have you thought about contamination? , 40% to have you thought of reusing lead markers after washing them? , and 80% to would you like to use it if reusable after wash? In the test for a contamination level of lead markers, in the both markers of an adhesive cotton plaster method and a gel pad method, more than 100 colonies were detected, and in the markers of a gel pad method which were cleaned with a microshield handwash, three colonies were detected. Conclusion : It is believed that a contamination level of lead markers can be minimized and infection risks which can be caused by lead markers can be reduced by changing an attachment method of lead markers that are used to indicate a patient position to a gel pad and washing it. 목 적 : 일반촬영검사에서 환자의 위치정보 표시를 위해 사용하는 납마커의 사용빈도와 이를 사용하는 임상 방사선사들의 납마커에 대한 오염인식도 및 오염실태에 대해 알아보고자 한다. 대상 및 방법 : 연구대상은 2015년 5월 2일부터 2015년 11월 2일까지 전국 방사선사 249명을 대상하였다. 연구 방법은 첫 번째로 납마커 사용빈도와 오염인식도에 대한 내용으로 총 13문항의 설문조사를 실시하였다. 납마커 사용빈도와 오염인식도에 대한 설문조사의 신뢰도 분석을 위해 SPSS Ver.23을 이용하여 Cronbach alpha값을 산출하였다. 두 번째로 납마커의 오염도를 알아보기 위해 납마커의 고정 및 부착을 위해 시용하는 재료들 중 설문 응답에서 가장 많은 응답률을 보인 면 반창고를 이용한 방식과 본원에서 사용중인 세척 후 재 점착이 가능한 젤패드를 이용한 방식을 이용 하였다. 면 반창고 방식과 젤패드 방식을 각각 1일동안 사용한 후 24시간 세균배양배지에 배양하여 세균이 얼마나 배양되는지 알아보았다. 세 번째로 세척 후 재 점착이 가능한 젤패드 방식의 오염도를 알아보기 위해 1일동안 사용한 젤패드 납마커를 손 씻기에 사용되는 마이크로쉴드로 세척한후 세균이 얼마나 배양되는지 알아보았다. 결 과 : 납마커 사용빈도에 대한 설문조사에서 납마커를 사용한다는 응답이 60%, 장비자체의 프로그램을 이용한 수동 삽입방식으로 마커를 사용한다는 설문에는 78%, 장비자체의 프로그램을 이용한 오토마킹을 사용한다는 설문에는 70%, 일반촬영검사에서 환자의 위치정보 표시를 위해 납마커가 필요하다는 설문에는 70%, 납마커의 사용이 환자 위치정보 오류를 줄 일 수 있다는 설문에는 80%, 납마커와 프로그램 마커를 같이 사용해야 한다는 설문에는 88%가 그렇다고 응답하였다. 납마커 사용에 있어 오염인식도에 대한 설문에서는“납마커가 깨끗할 것이다.”라는 설문에 50%, 납마커에“세균이 있을 것이다.”라는 설문에 75%,“ 감염의 우려가 있을 것이다.”라는 설문에 70%, 납마커의“오염에 대해 생각해 본적 있이 있냐?”는 설문에 50%, 납마커의“세척후 사용에 대하여 생각해 본적 있냐?”는 설문에 40%, 세척 사용이 가능하다면“사용해보고 싶냐?”는 설문에 80%가 그렇다고 응답하였다. 납마커 오염도 실험의 경우 1일동안 검사에 사용한 후 세 균배양배지에 24시간 배양한 면 반창고 방식의 마커와 젤패드방식의 마커에서 100colony 이상 검출되었고, 마이크로쉴도로 세척한 후 배양한 젤패드방식의 마커에서는 3colony가 검출되었다. 결 론 : 일반촬영검사에서 환자의 위치정보 표시를 위해 사용하는 납마커의 부착방식을 젤패드로 바꾸어 세척하여 사용한다면 납마커의 오염도를 최소화 할 수 있으며, 납마커로 인해 야기될수 있는 감염을 줄 일수 있을 것으로 사료된다.

      • A Strategy for Clearance Level Radioactive Waste; Used Laboratory Fume Hood

        YuJeong Choi,Han Byeol Kang,Hong Rae Jeon,Tack-Jin Kim 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.1

        It is important to make a strategy for clearance-level radioactive waste. Sampling and disposal plans should be drawn up with characteristics of target waste. In this paper, a target clearance-level radioactive waste is used in a laboratory for experiments with Cs-137 and Co-60, unsealed radioactive sources with gamma radiation isotopes. Therefore, it is enough to analyze with HPGe to check the contaminant level. The laboratory fume hood combined multiple materials, which means some are volume contamination and others are surface contamination. The wood, plastic, and drywall boards, which are absorbent volume contaminated parts and make up PVC pipes, base cabinet doors, backside baffles, etc., will be sampled with coring methods. The metals and glasses, which are unabsorbent, surface-contaminated parts, are sampled with smear methods. The work surface, baffles, exhaust plenum, and glass sash inside parts have a high possibility of being contaminated. The hood body, flame, base cabinet, PVC pipe (the rare end of the filter), and blower transition case have a low possibility of becoming contaminated. When we checked with HPGe, except for the work surface (which was below clearance level), other parts were less than MDA. The highest radionuclide concentration was in PVC pipe: Cs-137C 3.91E-02 (Bq/g), Co-60 4.54E- 03 (Bq/g). It is less than clearance level. Therefore, the waste was applied for the clearance level radioactive wastes and got permission from the regulatory body.

      • KCI등재

        서울시 토양오염 예방 대책 강화 방안

        원종석,배윤신,이상염,Won. Jong-Seok,Bae. Yoon-Shin,Lee. Sang-Yum 한국방재학회 2014 한국방재학회논문집 Vol.14 No.3

        서울특별시 수도권지역 내의 토양은 다양한 요소들에 의하여 오염되기 쉽고 오염된 토사들은 다시 원래 상태로 회복되는 것이 매우 어렵다. 하지만 이에 대한 서울특별시청(Seoul Metropolitan Government, SMG)의 시책은 일반적인 시책에 제한되어 있기 때문에, 서울특별시청은 서울시 내의 오염되는 토사의 예방에 대한 `토양 오염 경감 계획(Soil Contamination Mitigation Plans)`을 세워야할 필요가 있다. 이와 관련하여 본 연구의 목적은 토양 오염으로부터 이에 대한 예방 대책을 강화하고자 하는 계획을 제안하는 것이다. 이 연구는 3개의 부분으로 분류된다. 첫 번째로 토양오염의 사례들을 조사하였고, 두 번째로 서울시내의 토양에 대한 오염원 및 오염상태를 분석하였다. 마지막으로 서울시내의 토양 오염 경감 대책을 제안하였다. 토양 오염 경감 대책을 위한 추후의 추가적 연구로부터 제안된 계획은 오염되어질 토양을 예방하는 것에 크게 기여할 수 있다. 더욱이, 이것은 시민을 위한 안전 가업의 만족도를 상승시킬 수 있다. 이에 따라 본 연구에서는 서울시의 토양오염 예방대책에 관한 개선방안을 제시한다. Soils in Seoul Metropolitan Area are prone to contaminations from many sources and The Contaminated Soils are hard to be recovered. But Seoul Metropolitan Government(abbereviated to SMG)`s measures are limited to be some usual managements. So, SMG needs to have Soil Contamination Mitigation Plans for Preventing Soils in Seoul from being contaminated. This Study proposes Plans to develop preventing systems from Soil Contaminations. The Study consists of three parts. The first part exmaines cases of soil contaminations. The second part analyze soil contamination in Seoul. and The third part proposes the Soil Contamination Mitigation Plans in Seoul. The Proposed Plan by adding future projects for Soil Contamination Mitigation can support preventing soils from being contaminated. Further, it can contribute to improved satisfaction of safety services for citizen.

      • KCI등재

        Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste

        Gye-Hong Kim,Won-Zin Oh,Kune-Woo Lee,Bum-Kyoung Seo 한국방사성폐기물학회 2005 방사성폐기물학회지 Vol.3 No.3

        원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관류를 재활용하거나 처분하기 위해서는 배관 내부의 정확한 방사선학적인 오염 특성의 평가가 선행되어야 한다. 그러나 기존의 측정법인 survey-meter를 이용한 오염도의 직접 측정은 배관 내부와 같은 국소지역의 오염 특성을 정확하게 평가할 수 없으며, 간접법을 이용한 표면오염도 측정의 경우도 시료채취의 어려움뿐만 아니라 시료채취 시 작업자의 오염 가능성이 있기 때문에 적용성에 많은 문제점이 있다. 본 연구에서는 Monte Carlo 모사기법을 이용해 직경이 작은 배관 내부의 베타선 오염도를 측정하기 위하여 플라스틱 섬광체를 모사하였으며, 모사 결과에서 베타선 에너지를 효율적으로 측정할 수 있는 최적의 플라스틱 섬광체 두께 및 형상을 도출할 수 있었다. 이 전사모사 결과를 바탕으로 섬광체의 가공 및 배관 내부에서의 검출기 이송 문제를 고려해 검출기를 제작하였으며 그 특성을 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 검출기 성능을 확인하였고, 파이프 내부처럼 국소 지역의 방사선학적 오염 특성 평가를 위한 검출기 개발 가능성을 확인하였다. The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

      • KCI등재

        LevelⅠFugacity Model을 이용한 Biopile 내 유기화합물 5종의 분포 예측

        김계훈(Kye-Hoon Kim),김호진(Ho-Jin Kim),Simon J.T. Pollard 한국토양비료학회 2008 한국토양비료학회지 Vol.41 No.3

        본 연구는 level I fugacity model을 이용하여 유류오염 토양에서 많이 존재하며 생태적 위해성이 큰 다섯가지 유기성 오염물질(anthracene, benzene, benzo[a]pyrene, 1-methylphenanthrene, phenanthrene)이 기상, 액상, 고상 및 비수용성액체(NAPL)의 네 가지 상(phase)으로 구성된 biopile 내에서 어떻게 분포하는가를 예측하기 위하여 수행하였다. 이를 위하여 영국 내에서 장기간 유류로 오염된 세 지역으로부터 토양 시료를 채취, 분석하였고 토양 분석 결과와 관련 인자를 level I fugacity model에 입력하여 fugacity 및 오염물질의 토양 중 분포를 구하였다. 다섯 오염물질의 fugacity 간에는 큰 차이가 있었으나 동일 오염물질은 시료 간 fugacity에서 별다른 차이를 보이지 않았다. 모든 오염물질은 NAPL과 고상에 주로 존재하였으며 토양시료간의 유기탄소함량 차이가 오염물질의 분배 동태에 큰 영향을 미쳤다. Benzene은 기상과 액상에 높은 농도로 존재함으로써 위해성에 근거한 기상과 액상 중 benzene 관리의 중요성을 나타내었다. 반면 다른 오염물질은 기상과 액상에 거의 존재하지 않음을 보임으로써 지하수 오염 가능성을 현저하게 감소시켰다. 본 연구의 결과는 위해성이 큰 오염물질과 복원 처리를 토양 내 오염물질 잔류 농도 간에 관련이 있음을 보였으며 또한 유류오염 토양의 위해성 평가 과정에서 NAPL과 고상을 고려하는 일의 중요성도 나타내었다. The purpose of this study was to predict environmental distribution of anthracene, benzene, benzo[a]pyrene, 1-methylphenanthrene and phenanthrene in a four phase biopile system ? air, water, soil and non aqueous phase liquid (NAPL) phase using level I fugacity model. Soil samples used for this study were collected from three sites in the United Kingdom which were historically contaminated with petroleum hydrocarbons. The level I fugacities (f) for the five contaminants were markedly different, however, the fugacities of each contaminant in three soil samples did not show significant difference. NAPL and soil were the dominant phases for all five contaminants. Results of this study indicated that difference in percentage of organic carbon strongly influenced the partitioning behavior of the contaminants. The presence of benzene calls for an urgent need for risk-based management of air and water phase. Whereas insignificant amount of chemicals leached in the water phase for other organic contaminants showing greatly reduced potential of groundwater contamination. Furthermore, this study helped us to confirm the association of risk critical contaminants with the residual saturation in treated soils. They also can be used to emphasize the importance of accounting for the partitioning behavior of both NAPL and soil phases in the process of the risk assessment of the sites contaminated with petroleum hydrocarbons.

      • 방사성옥소 치료환자의 환의 및 침구류에 대한 표면오염 측정에 관한 고찰

        문재승,박대성,김수근,정희일,Moon, Jae-Seung,Park, Dae-Seong,Kim, Su-Keun,Jeong, Hee-Il 대한핵의학기술학회 2008 핵의학 기술 Vol.12 No.1

        목적: 방사성옥소 치료시 환자의 배설물(침, 소변)을 통해 표면 오염된 환의 및 침구류를 방사선 측정기로 측정하여 방사성 폐기물의 적정보관기간을 산출하고자 하였다. 대상 및 방법: 2005년도 8월부터 2006년 2월까지 방사성옥소 치료를 받은 환자 70명(남자: 12명, 여자: 58명)이 사용한 환의 및 침구류를 대조군(60 case)과 비대조군(10 case)으로 나누어 측정하였다. 결과: 세탁하지 않고 자체보관한 대조군과 세탁 후 자체 보관한 비대조군의 적정보관기간은 대조군 $44{\pm}16$일, 비대조군 $32{\pm}13$일으로 대조군과 비대조군의 보관기간에 있어서 유의미한 차이가 있는 것으로 나타났다(p<0.001). 환의 및 침구류에 대한 세탁전후의 표면오염도 제염효과는 평균 $83.66{\pm}15.15%$로 나타났으며, 오염 확산여부를 측정하기 위해 실시 된 결과에서 최초 표면오염 되지 않았던 환의에 미치는 영향은 미비하였다(p<0.05). 그러나 세탁과정 중에 발생된 세탁폐액에 대한 오염도는 최초 표면오염의 정도에 따라 허용표면 오염도 수준을 벗어난 것도 있었다. 결론: 표면 오염된 환의 및 침구류 전체를 방사선 측정기로 측정한 후 표면오염도의 정도에 따라 분류하고 적정 보관 기간이후 관리구역 밖으로 불출하는 것이 유용할 것이다. Purpose: Contaminated clothes and bedclothes of patients by mouth or with excrement are produced after Radioisotope $^{131}I$ treatment. In this paper, patient's clothes and bedclothes contaminated by radioactivity measured and radioactive waste wish to calculate optimum storage period. Material and Methods: The whole area of patients' clothes and bedclothes measured 70 patients, 12 males and 58 females, who had radioisotope $^{131}I$ therapy between August 2005 and February 2006. Assuming contamination is evenly distributed, the radioscope used to measure up to social toleration level at 7 day intervals. Results: Each optimum storage period of control group of 60 case and non control group of 10 case were average $44{\pm}16$ days and $32{\pm}13$ days. Decontamination effect of surface contamination for radioactive waste was average $83.66{\pm}15.15%$. Conclusion: It is important that classify radioactive waste according to difference of surface contamination. Result of this research, handling radioactive waste in optimum storage period may be useful.

      • SCOPUSKCI등재

        시중 판매 후추의 오염도 및 회분식 광펄스 처리에 의한 살균 효과

        박지현(Jihyun Park),신정규(Jung-Kue Shin) 한국식품과학회 2016 한국식품과학회지 Vol.48 No.5

        시중에서 판매되고 있는 후추 29종을 수거하여 오염도를 조사한 결과, 전통시장에서 구입한 후추는 일반세균 10<SUP>6</SUP>-10<SUP>7</SUP>, Bacillus 10⁴-10<SUP>5</SUP>, 효모와 곰팡이 10² 이하의 오염도를 보였고, 유기농 제품으로 판매되는 후추의 경우에는 일반세균 10⁴, Bacillus 10²-10³, 효모는 10¹ 이하의 오염도를 나타내었다. 대형마트에서 판매되고 있는 후추는 낮은 오염도를 나타내었으나 일부에서는 일반세균이 10³ 정도의 오염도를 보였다. 전압 1,000 V, 펄스수 5 pps, 시료와 램프사이의 거리 4 cm의 조건에서 10분간 광펄스 처리하였을 경우 통후추는 1.45-1.55 log, 흑후추분말과 백후추분말은 0.8-0.85 log의 사멸율을 나타내었다. 살균 용기의 차이에 따른 살균율에는 유의적인 차이를 나타내지 않았다. 광펄스에 의한 후추의 살균율은 오존처리나 감압방전프라즈마 살균 등 다른 비가열 살균방법에 비해서는 높은 사멸율을 보여 산업적 적용 가능성을 보였으나, 추가적인 연구를 통해 살균 효과를 높일 수 있는 방법이 제시되어야 할 것으로 판단된다. Twenty-nine pepper products commercially available in the market were collected and investigate for contamination levels. Pepper products purchased from traditional markets had a degree of contamination of 10<SUP>6</SUP>-10<SUP>7</SUP> CFU/g aerobic bacteria, 10⁴-10<SUP>5</SUP> CFU/g Bacillus sp., and less than 10² CFU/g yeast and molds. Organic pepper showed a degree of contamination of 10⁴ aerobic bacteria, 10²-10³ Bacillus sp., and less than 10¹ yeast and molds. Intense pulsed light (IPL) treatment of 10 min (1,000 V, 5 pps and 4 cm sample-to-lamp distance) showed a bacterial death rate of 1.45-1.55 log for whole peppers, and of 0.8-0.85 log for black and white pepper powder. The sterilization rate using IPL was higher than that using other non-thermal sterilization methods, such as ozone treatment or low-pressure discharge plasma sterilization, indicating that the IPL sterilization method may find potential application in the industry. However, further studies may need to be conducted to enhance the effect of sterilization.

      • KCI등재

        제주도 관정 공벽 내 오염물질 유입 구간 탐지 및 차단 사례

        송성호,황보동준,김진성,양원석 한국지하수토양환경학회 2022 지하수토양환경 Vol.27 No.3

        Most wells developed in Jeju island before the enactment of the Groundwater Management Ordinance in 2002 arevulnerable to aquifer contamination due to inflow of upper groundwater having the high concentration of nitrate nitrogen,likely due to incomplete grouting in upper section of the wells. Although these wells require entire reinstallation, it is oftennecessary to rehabilitate the existing wells due to various constraints. Therefore, to identified the inflow section ofcontaminants, the thermal level sensor (TLS) technique was firstly applied for three wells, which enables to monitortemperature variations in every 50 cm depth. Then, the grouting material was injected to the upper section to prevent theinflow of upper contaminated groundwater into the entire aquifer. By applying TLS technique, it was found that thetemperature deviations in the upper groundwater inflow section decreased sharply. Moreover, both the change in theconcentration of nitrate nitrogen in the rainy/dry seasons and the average concentrations were found to decrease rapidlyafter grouting material injection. Consequently, the application of TLS proposed in the study turned out to be appropriateto prevent aquifer contamination.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼