http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Spontaneously Hypertensive Rat에서 Arginine Vasopressin의 신장효과
김종훈,조경우,윤영의,Kim, Jong-Hun,Cho, Kyung-Woo,Yun, Young-Yi 대한생리학회 1987 대한생리학회지 Vol.21 No.2
There have been reports on the aberration of the control mechanisms of the blood pressure, hormone secretion, and renal functions in spontaneously hypertensive rats (SHR). However, the contribution of the renin-angiotensin system in the maintenance of high blood pressure in SHR is still controversial. Recently, it has been reported that the negative feedback short loop control mechanism of the renin-angiotensin system may be changed in SHR. In the present experiment, it was attempted to explore the possible alterations in the effect of arginine vasopressin (AVP) on the renal function in SHR. Experiments have been done in anesthetized SHR as well as in normotensive Wistar and Sprague-Dawley rats as control groups. Pharmacologic doses of AVP (10-13 mU/rat/10 min) decreased urine volume, excreted amount of creatinine and para-amino-hippuric acid. No differences in these parameters was observed between normotensive and hypertensive rats. AVP increased sodium and potassium excretion, but the responses in SHR were suppressed as compared with normotensive rats. Intravenous infusion of AVP also increased blood pressure in normotensive and hypertensive rats and a vasopressor effect of AVP was attenuated in SHR. There was a positive correlation between the changes in blood pressure and excreted amount of sodium during AVP infusion. These data suggest that the attenuated natriuretic effect of intravenous infusion of AVP may be due to a difference in renal tubular responsiveness to AVP but not due to a difference in vasopressor responsiveness.
김종훈,최용욱,Kim, Jong Hun,Choi, Yong Wook 대한화학회 1996 대한화학회지 Vol.40 No.2
전라북도 내에 최근 새로이 개발된 온천수와 그곳 지하수의 수질 화학적 특성과 연대(나이)에 관하여 연구하였다. 수질 화학적 특성중 온도는 27-29$^{\circ}C$의 미온천이며, $F^-$이온은 평균 2-13ppm으로 매우 높게 나타났고, $NO_3^-$이온은 거의 검출되지 않았다, $SO_4^{2-}$는0.02-23ppm이었으나 이중 유황천으로 알려진 $Y_3$의 $SO_4^{2-}$함량은 다른 지역보다 최소 2배에서 최대 40배 이상 높게 나타났다. Diagram에 의한 분류에서 $Y_1,\;Y_3,\;Y_5,\;Y_2,\;Y_4,\;Y_8$은 $HCO_3^-$형, $Y_6$는 $CI^-$형, $Y_7$은 특징없는 물로 분류되었다. 강수(precipitation)와 온천수의 삼중수소 준위를 기초로 한 연대측정에서 piston flow model에 의해 $Y_1$은 -89년으로 가장 오래된 온천수며, $Y_7$은 -2년으로 가장 최근의 물로 계산되었다. 또한 dispersive model에 의한 값도 $Y_1$은 89년, $Y_7$은 2년된 물로 계산되어 piston flow model값과 거의 같은 결과를 얻었다. The chemical characteristics and age dating of the thermal springwater developed recently in Chullabukdo were investigated. The temperature range of the thermal springwater was found 27∼29$^{\circ}C$, indicating a low temperature thermal springwater. The concentration of $F^-$ ion in the springwater was found relatively high in the range of 2∼3 ppm, but $NO_3^-$ ion was nearly not detected. The concentration range of $SO_4^{2-}$ ion was 0.02∼23 ppm, among which $SO_4^{2-}$ content of $Y_3$ was found very high compared to that of other springwater, since this site is known as a sulfur spring. $HCO_3^-$ ion content was found 2∼5 times higher than that of groundwater. $Y_1,\;Y_3,\;Y_5,\;Y_2,\;Y_4,\;and\;Y_8$, were classified as $HCO_3^-$ type, $Y_6$ as $CI^-$type, and $Y_7$, as no domonant type by classification diagram for anion and cation facies. From the results of age dating on the basis of the mean tritium level of precipitation and thermal springs, $Y_1$ was identified as the oldest thermal spring (-89 years) and $Y_7$ was identified as -89 years and $Y_7$ was -1 year using dispersive model. The results calculated by two models agreed well each other.
소프트웨어 RAID 파일 시스템에 작은 쓰기와 참조 횟수를 고려한 캐쉬 교체 정책
김종훈,노삼혁,원유헌,Kim, Jong-Hoon,Noh, Sam-Hyuk,Won, Yoo-Hun 한국정보처리학회 1997 정보처리논문지 Vol.4 No.11
본 논문에서는 소프트웨어 RAID 파일 시스템에서 효율적인 캐쉬 교체 정책들을 제안한다. 그리고 이와 기존의 캐쉬 교체 정책을 소프트웨어 RAID 파일 시스템에 적용한 정책들과의 성능을 다양한 환경에서 비교한다. 실험을 통해 우선 소프트웨어 RAID 파일 시스템에서 작은 쓰기 동작은 성능을 크게 저하시키는 요소임을 확인한다. 이러한 작은 쓰기 동작을 줄이는 캐쉬 교체 정책들을 제안한다. 이러한 교체 정책들에 대한 성능 비교는 트레이스 기반 시뮬레이션에 의해 수행된다. 실험 결과를 통해 본 논문에서 제안한 교체 정책들이 기존의 정책들 비해 효율적인 성능을 나타냄을 확인한다. In this paper, we present efficient cache replacement policies for the software RAID file system. The performance of this policies is compared to two other policies previously proposed for conventional file systems and adapted for the software RAID file system. As in hardware RAID systems, we found small-writes to be the performance bottleneck in software RAID file systems. To tackle this small-write problem, we propose cache replacement policies. Using trace driven simulations we show that the proposed policies improve performance in the aspect of the average response time and the average system busy time.
단일 컬럼이온크로마토그래피에 의한 광천수중 음이온의 신속한 동시정량
김종훈,최용욱,정택균,Kim, Jong Hun,Choi, Yong Wook,Chung, Taek Kyun 대한화학회 1995 대한화학회지 Vol.39 No.12
단일컬럼 이온 크로마토그래피에서 $F^-,Cl^-,NO_2^-,NO_3^{2-}$의 다섯 가지 음이온에 대한 최적 분리 조건과 분석 시간에 대하여 연구하였다. 프탈산 용리액에서 용리액의 농도를 2.0에서 3.5mM까지, 용리액의 pH를 3.5에서 4.5까지 변화시킨 결과 2.0mM pH 4.5가 가장 최적 조건임을 알 수 있었다. 용리액의 농도 및 pH가 증가할수록 용리강도는 증가하였고 음이온들은 $F^-,Cl^-,NO_2^-,NO_3^{2-}$ 및 $SO_3^2-$순으로 모두 10분이내로 바닥선 분리되어 용리하였다. 또한 이 조건에서 다른 조건보다 검출기 감도가 비록 감소하였으나 시스템 봉우리가 분석에 영향을 미치지 않을 정도로 감소하였기 때문에 연속분석시 분석 시간을 약 40% 단축할 수 있었다. 이 조건하에서 다섯 가지 음이온의 검정 곡선은 모두 상관 계수가 0.999 이상이었으며 9종의 시판 생수를 분석하였다. Analytical conditions for single column ion chromatographic determination of five anions such as F-, Cl-, NO2-, NO3-, and SO42- were optimized with respect to analysis time and separation efficiency. At the optimum condition of 2.0 mM phthalic acid at pH 4.5, five anions were effectively separated in 10 minutes so that analysis time could be reduced by 40% compared to other recommended conditions. Under this condition all the calibration curves of five anions were linear with a correlation coefficient > 0.999. Analytical results for nine commercial bottled waters were presented.