http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김경엽,박기태,김태오,김광하,허정,강대환,송근암,조몽 대한소화기내시경학회 2007 Clinical Endoscopy Vol.34 No.1
Background/Aims: Endoscopic grading of the gastroesophageal flap valve (GEFV) was suggested to be a good predictor of the gastroesophageal reflux status. The aim of this study was to examine the association between the GEFV and gastroesophageal reflux. Methods: A total of 599 patients (245 men and 354 women; mean age 51.0 0.5 years) who underwent endoscopy, esophageal manometry, and ambulatory pH monitoring were included. GEFV was graded I through to IV using Hill's classification. The GEFV was classified into main 2 groups: the normal GEFV (grade I and II) and the abnormal GEFV groups (grade III and IV). The findings of endoscopy, esophageal manometry, and ambulatory pH monitoring were compared. Results: An increased GEFV grade was significantly associated with reflux esophagitis and Barrett's epithelium (p<0.001). The LES pressure was significantly lower in the abnormal GEFV group (p<0.001). All variables showing gastroesophageal reflux in the probe were significantly higher in the abnormal GEFV group (p<0.001). The frequency of gastroesophageal reflux disease (GERD) was higher in the abnormal GEFV group (p<0.001). Conclusions: There is an association between the altered geometry of the GEFV and the presence of GERD. The endoscopic grading of the GEFV is easy and provides useful information on the gastroesophageal reflux status. (Korean J Gastrointest Endosc 2007;34:1-8) 목적: 위식도 판막의 내시경 등급화는 위식도역류 상태를 예측할 수 있는 좋은 지표가 된다. 본 연구를 통해 위식도 판막과 위식도역류의 연관성에 대해 알아보았다. 대상 및 방법: 2004년 1월부터 2005년 6월까지 위식도역류 증상으로 부산대학교병원 운동검사실로 의뢰되어 상부위장관 내시경검사, 식도 내압검사, 24시간 보행성 식도 산도검사를 모두 시행한 599명의 환자(남자 245명, 여자 354명; 평균 연령 51.0±0.5세)를 대상으로 하였다. 위식도 판막은 Hill 분류법에 의하여 I~IV도로 등급화하였고, I도와 II도는 정상 위식도 판막군으로, III도와 IV도는 비정상 위식도 판막군으로 구분하였으며 각 군 간에 상부위장관 내시경검사, 식도 내압검사, 24시간 보행성 식도 산도검사 등의 결과를 비교 분석하였다. 결과: 위식도 판막 등급이 증가할수록 역류성 식도염과 바렛상피의 빈도가 유의하게 증가하였다(p<0.001). 하부식도 괄약근압은 비정상 위식도 판막군이 정상군보다 유의하게 낮았다(p<0.001). 24시간 보행성 식도 산도검사에서는 위식도역류를 나타내는 모든 변수가 비정상 위식도 판막군이 정상군보다 유의하게 높았다(p<0.001). 보행성 식도 산도검사로 정의한 위식도역류질환의 빈도도 비정상 위식도 판막군이 정상군보다 유의하게 높았다(74.1% vs. 33.6%, p<0.001). 결론: 위식도 판막의 형태 및 구조는 위식도역류질환과 연관성이 있으며 이러한 위식도 판막의 내시경적 등급화는 쉽고 간편하면서 위식도역류 상태에 대한 유용한 정보를 제공해 준다.
김경엽,김종호,이현경,김하영,문보연,이유란,박중원,소병재,배유찬,Kim, Gyeongyeob,Kim, Jongho,Lee, Hyunkyoung,Kim, Ha-Young,Moon, Bo-Youn,Lee, Yu-Ran,Park, Jungwon,So, Byungjae,Bae, Youchan 대한수의학회 2022 大韓獸醫學會誌 Vol.62 No.1
This paper describes a fatal case of pneumonia in a 14-day-old dog caused by extraintestinal pathogenic Escherichia coli (ExPEC). The necropsy showed that almost all of left lobes of the lungs had dark-red consolidation. A histopathology examination revealed moderate acute fibrino-hemorrhagic necrotizing pneumonia with intralesional bacterial colonies. Non-suppurative epicarditis, congestion in the liver, and necrosis in the white pulp of the spleen also were found. E. coli with cytotoxic necrotizing factor 1 and α-hemolysin was isolated from the lung. This case was confirmed to have fatal pneumonia caused by ExPEC that led to a systemic infection.
UKF를 이용한 정전용량형 수동센서시스템의 파라메타 추정
김경엽,이준탁 東亞大學校附設 淸報技術硏究所 2006 情報技術硏究所論文誌 Vol.13 No.2
In this paper, a noisy passive telemetry sensor system using Unscented Kalman Filter (UKF) is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system IC chip has, the principle of inductive coupling was applied to the modelling of a passive telemetry sensor system (PTSS) and its noisy capacitive parameter was estimated by the UKF algorithm in time domain. Specially, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization.
김경엽,이영호 한국마린엔지니어링학회 1997 한국마린엔지니어링학회지 Vol.21 No.4
본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.