      • 간섭현상을 이용한 렌즈의 특성조사

        마기중,심훈 대한안경사협회 1993 眼鏡界 Vol.96 No.1

        We investigated the optical characteristics of a bi-convex lens using interferometric method. A Twyman-Green interferometer has been constructed for assessment of the lens. As a coherent lihgt, a spatially filtered and collimated He-Ne laser beam was employed. The fringe, formed by interference, was detected by a CCD camera with spatial resolution, l0㎛ and displayed by a multi-synchronizing CRT monitor. The intensity distribution of the interferogram was digitized by a image card, and processed and analyzed by a personal computer. The focal point and power of a lens were determined with the accuracy comparable to the light wavelength. The astigmatic aberration and a fine mechanical defect on the surface of the lens under test were also observed

      • 콘택트렌즈 착용자에서 각막곡률과 TBUT의 변화

        마기중,이군자 서울보건대학 1999 서울보건대학 부설 한국보건과학연구소 논문집 Vol.5 No.1

        RGP 및 Soft 콘택트렌즈 착용자 28명을 대상으로 콘택트렌즈 착용 후 1년 동안 각막곡률과 굴절이상도 및 눈물의 변화도를 알아보았다. 각막곡률과 굴절이상도에 대한 데이터분석은 디옵터굴절력을 디옵터굴절력매트릭스로 변환시키고 단변량 및 다변량 통계분석을 하고 3차원 h벡터 공간에 신뢰영역을 도시하였다. 각막곡률의 평균변화도는 RGP 착용군에서 주로 h_(3) 성분이 플랫하게 변화되며 1년후에는 수평성분도 플랫하게 변화되었고, Soft 착용군에서는 착용초기 플랫하게 변하다가 1년후에는 약간 스티프해지는 변화를 보였으나, 착용전후 각막곡률의 평균에 대한 3변량 가설검증 결과 두 그룹 모두 착용전과 비교하여 차이가 없는 것으로 나타났다(w<F_(0.05. 3. n-3)). 굴절이상도의 평균변화도는 RGP착용군에서 h_(1) 및 h_(3) 성분이 착용전과 비교하여 감소한 것으로 나타났으나 (p<0.05), Soft 착용군에서는 유의한 차이가 없었으며, 3변량 가설검증 결과 두 그룹 모두 착용전과 비교하여 차이가 없는 것으로 나타났다(w<F_(0.05. 3. n-3)). 각막곡률의 변화와 굴절이상도의 변화는 RGP 착용군에서 h_(2) 성분만 낮은 상관관계를 보였다(p<0.05). 비침입성 눈물막 파괴시간은 침입성 눈물막 파괴시간보다 평균값에서 길게 측정 되었으나 통계학적으로 유의한 차이는 나타나지 않았다. 눈물막 파괴시간을 측정하는 TBUT 방법과 NIBUT 방법은 서로 상관관계가 없는 것으로 나타났다. 콘택트렌즈 l년 착용군의 TBUT 검사에 의한 눈물막 파괴시간은 대조군에 비하여 감소하였으며 통계학적으로도 유의한 차이가 나타났다 (p<0.05). 따라서 RGP 렌즈를 장기간 착용하게 되면 각막굴절력 및 각막난시도의 감소와 굴절이상도의 구면성분 및 원주성분이 감소될 것이며, 콘택트렌즈 착용에 의하여 눈물이 불안정해진다고 생각된다. 28 patients wearing RGP and soft contact lenses were studied for one year. Data analysis of variation in corneal curvature and refractive error was carried out using matrix representations of conventional dioptric power. Confidence regions for mean dioptric power were represented by principal axes in a 3 - D space called h - space. Variations in the corneal curvature of RGP Group did show a significant decrease (h_(3) component). but those of Soft Group showed irregular change of intial flattening and minor steepening during experimental period. Variations in refractive error were significant decrease in both h1 component and h₃component of RGP Group. However, no significant changes were found in either corneal curvature and refractive error by the multi-variate statistics. NIBUT values were slightly higher than the TBUT values in average. but there was no difference statistically in control eyes. No significant correlation was found in either TBUT or NIBUT values. The stability of the precorneal tear film after 1year of wear was slightly lower than those of the precorneal tear film before lens insertion in the values of TBUT.

      • 연속착용 콘택트렌즈에 의한 각막부종

        마기중 서울保健大學 1996 論文集 Vol.16 No.1

        각막질환이 없고 콘택트렌즈를 착용하지 않고 있는 근시안을 대상으로 국내 제품의 3가지 소프트 콘택트렌즈를 착용시키고 9시간 동안 취침을 시킨 후 유발된 각막부종과 회복되는 시간을 측정하였다. 각막두께는 optical pachometer 를 사용하여 매번 10회씩 측정하여 평균값을 얻었다. 대조군의 overnight corneal swelling은 2.34%였으며, 각 렌즈에 대한 overnight corneal swelling은 A 렌즈 8.49%, B 렌즈 12.34% 및 C렌즈 11.19%로, A 렌즈와 나머지 렌즈 사이에 유의한 차이가 있었다(p<0.05). 또한 deswelling에 대한분석 결과대조군에서 기상 후 1시간이 지났을 때 잠자기 전의 각막두께로 회복되었으며, 콘택트렌즈 착용군에서는 A 렌즈를 착용했을 때에만 기상 후 3시간이 지난 후 잠자기 전의 수준으로 회복되었다. 콘택트렌즈의 Dk/L값과 overnight corneal swelling은 상관관계가 높은 것으로 나타났다. 이상의 결과로부터 본 연구에 사용된 국내 제품의 렌즈는 매일착용이 안전하고, 연속착용하는 경우 각막부종으로 인한 부작용을 예방하기 위한 정기검진이 필요할 것으로 생각된다. An overnight study was performed to measure the corneal swelling and deswelling induced by three soft contact lenses manufactured in Korea. All subjects were no lens wear or inexperienced to contact lens wear. The overnight corneal swelling of 5 subjects(l0 eyes) was measured with an optical pachometer. Corneal thichness measurements were taken just before eye closure and after nine hours of sleep. The overnight corneal swelling in control group was 2.34 %, and those in contact lens wearing groups were 8.49% for A lens, 12.34% for B lens, 11.19% for C lens, respectively, Overnight swelling for A lens was significantly less than that for the other lenses(p<0.05). Cornea] deswelling time to the level of a base line(pre-sleep) with no lens wear occurred within 1 hour in control group. Among the contact lens wearing groups, corneal deswelling occurred in 3 hours for A lens only, The average corneal swelling response for A and B lens was inversely proportional to the oxygen transmissibility(Dk/L) of the lenses. It was considered that the contact lenses in this study used were appropriate for daily wear mode, and careful evaluation should be need to prevent from adverse effects during extended wear.

      • 한국인에서 표준모형안의 설계

        마기중,이군자,이동희,이명하 凡石學術奬學財團 2000 凡石學術論文集 Vol.4 No.1

        The purpose of our study was modelling of schematic eye in Korean. Subjects for the study were 105 students(average 23.5 years) in department of ophthalmic optics of Seoul Health College. Ocular components were measured by Orbscan topography system. ultrasonic pachymetry, and A-scan ultrasonography under cycloplegic condition. Crystalline lens radii were calculated by Bennett's method. Prior to obtain the data for modelling of schematic eye in Korean, we were assess the various methods for measurements of principal optical dimensions. Equivalent powers and principal points of schematic eye were calculated using the Gaussian paraxial equation. Refractive indices of intraocular media were used values in Gullstrand - Emseley schematic eye. Korean four-surface schematic eye modelled by authors was significant different in Gullstrand - Emsley three-surface schematic eye. That is emmetropic eyes of Korean were flatter anterior radius of cornea, steeper posterior radius of cornea, weaker equivalent corneal power, thinner lens thickness, weaker equivalent lens power, shorter axial length and stronger equivalent power of the eye than Gullstrand - Emsley schematic eye.

      • 한국인 근시안의 각막형태에 관한 연구

        마기중,심훈,이군자 서울보건대학 1995 서울보건대학 부설 한국보건과학연구소 논문집 Vol.1 No.1

        The analysis and description of corneal topography is receiving more attention in contact lens fitting procedures and eximer laser photokeratectomy. It is known that there are inter-racial differences in corneal topography. In this study, we measured the refractive error and the corneal contour of 475 myopic eyes. The corneal topography was analyzed by using the EyeSys Corneal Analysis System V 2.1V. There is no significant correlation between the refractive error and the K-reading. We found that the K-readings were significantly different between males and females. The K-reading of Korean was similar to that of Chinese, but it was different from that of Caucasians. The rate of peripheral flattening in the nasal and temporal region is not symmetric, and curvature of the nasal peripheral region is the flattest in horizontal and vertical meridians of the cornea.

      • Interferometry에 의한 렌즈의 수차 분석

        심훈,마기중 서울保健大學 1994 論文集 Vol.14 No.1

        The monochromatic aberration characteristics of a lens were analyzed by using the Twyman-Green interferometer. The interference fringes formed by a spectacle lens were observed and compared with the theoretical results. In particular, the characteristics of astigmatism of the lens were investigated. The positions of sagittal and tangential focal planes and the least confusion circle were determined. The intensity distribution of the interferograms were captured with a CCD array and digitized by a real time VGA frame grabber.

      • 동체시력 측정에 관한 연구

        이명하,마기중 서울保健大學 1996 論文集 Vol.16 No.1

        정지시력(Staic Visual Acuity)은 물체와 관찰자가 정지한 상태에서 사물을 볼 수 있는 능력을 의미한다. 이와 달리 동체시력 (Dynamic Visual Acuity)은 물체나 관찰자가 움직이는 상태에서 사물을 볼 수 있는 능력을 의미한다. 즉 정지시력은 주로 눈의 해상력과 관계가 있으나 동체시력은 안구운동계의 전반적인 능률(efficiency)과 관계가 깊다. 따라서 동일한 정지시력(SVA)을 갖고 있더라도 동체시력(SVA)은 차이가 날 수 있다. 본 연구는 일반인과 일반인에 비해 시각적 능력이 우수하다고 알려져 있는 운동선수의 동체시력을 측정, 비교하였다. 각 군의 동체시력은 틈의 방향이 각기 다른 Landolt Cs 시표와 본 연구를 위해 개발한 회전거울식 장치를 사용하여 구하였다. 각 군의 평균 동체시력은 일반인군이 78.46±15.67 deg/sec였으며 운동선수군은 93.33±14.14deg/sec으로 운동선수군이 일반인군에 비해 동체시력이 우수함을 알 수 있었다. 본 연구에서 동체시력 측정장치의 제작과 이를 활용한 동체시력의 측정 분석을 통해 동체시력에 관련된 기초 자료를 얻은 바, 앞으로 동체시력을 연구하는데 도움을 줄 수 있을 것으로 기대된다 Individuals with simmilar static visual acuity(SVA) have widely different dynamic visual acuity(DVA). While SVA is primarily related. to the resolving power of eye, DVA is related more to the efficiency of the entire oculomotor system. At low target velocites, there is high correlation between SVA and DVA, while the correlation decreases as target velocity is increased. This study was the DVA compared using samples of nonathlete college students(male 14, female 12) and athletes(9 fensing players in middle school). Subject reported diretion of Landolt Cs target(2.1cm in projected size) exhibting uniform angular motion produced by rotating mirror projection system. The results showed a statistically significant difference between the nonathlete and athletes groups. The mean DVA is 78.46±15.67degjsec for the nonathletes group and 93.33±14.14deg/sec for athletes group. Also, SVA is not related DVA in athletes. It was considered that these results will provide a foundamental data for the future study of the sports and visual performance.

      • CIE X_(10) Y_(10) Z_(10)색표시계에 따른 선글라스용 렌즈의 측색

        박수봉,마기중 金泉大學 1992 논문집 Vol.11 No.1

        시감투과율이 82%이상으로 한국규격에서 선글라스용 렌즈로 구분될 수 없는 23개 렌즈를 제외한 22개 렌즈에 대해서 CIE X_(10) Y_(10) Z_(10)색표시계에 따른 주파장과 자극순도를 조사한 결과는 다음과 같다. 1. 각기 다른 염료로 착색된 렌즈의 주파장은 각각 갈색 : 582-596nm(CIE A). 575-590nm(CIE B). 572-587nm(CIE D_(65)), 핑크색 : 592-595nm(CIE A). 589-592nm(CIE B). 588-591nm(CIE D_(65)), 청색 : 481-485nm(CIE A). 475-479nm(CIE B). 474-477nm(CIE D_(65), 녹색 : 556-564nm(CIE A). 550-556nm(CIE B). 547-553nm(CIE D_(65))이었다. 2. 자극순도가 25% 이상으로 KS규격을 초과한 렌즈의 염료별 착색시간은 각각 갈색 :30초 이상 (CIE A & D_(65)) 1분이상 (CIE B), 핑크색 : 2분 이상 (CIE A), 5분이상 (CIE D65 & 8), 청색 : 10분 이상 (CIE D_(65)), 20분 이상(CIE B), 녹색 : 20분 이상(CIE A, D_(65) & B)이었다. 한편 평균주광 (D_(65)) 의 color shifts 에 대한 ANSI규격을 초과한 렌즈는 5분 이상 갈색 염료로 착색된 렌즈와 20분 동안 착색된 핑크색 렌즈뿐이었다. The transmittance properties of 45 dyed CR-39 lenses were examined to determine whether these lenses met the KS P-4404 Lenses for Sunglass standards for excitation purity, and colorimetered according to the CIE 1964 supplementary standard colorimetric system. Approximately 50% of the sampled dyed lenses failed to meet KS requirement for luminous transmittance. Of 22 lenses that passed to KS requirement for luminous transmittance. only 11 lenses that met KS requirement for exitation purity.

      • KCI등재

        The Analysis of the Clinical Performance' of the URK-700 Autorefractor

        Ki-Choong Mah,Suk-ju Kim,Hae-jung Lee 대한시과학회 2006 대한시과학회지 Vol.8 No.2

        국내에서 개발된 자동굴절계 (URK 700, Unicos사)의 임상성능을 분석하기 위하여 50 명 (100 안)을 대상으로 자동굴절검사와 자각식굴절검사를 실시하였다. 표준표기법의 굴절이상도를 벡터 (h)로 전환하여 수평성분 (hl) , 회선성분 (hz) , 및 수직성분 (h3) 에 대 하여 분석하였다. 동일한 대상을 최소 30분 간격을 두고 2 회 측정한 자동굴절검사값의 평균은 모든 성분에서 유의한 차이가 없었으며, 95% 일치구간은 수평성분 -0.83D - +0.78D, 회선 성분 -0.21D - +0.21D 및 수직성분 -0.82D - +0.78D 였다. 자각식 굴절검사값과 자동굴 절계로 측정한 굴절이상도의 평균 차이는 수평성분(hl) -0.15:t0.5ID, 회선성분(hz) -0.03:t 0.14D, 수직성분(h3) -0.34 :t 0.55D 였으며, 95% 일치구간은 수평성분 -1.l4D-+0.85D, 회선성분 -0.31D - +0.25D 및 수직성분 1.42D-+0.73D 였다. 자각식 굴절검사값과 자 동굴절검사값의 차이가 임상적으로 유의한 수준인 0.50D 이상을 보인 빈도는 수평성 분 17%, 회선성분 0% 및 수직성분 23% 였다. 이상의 결과를 종합하면 URK 700 자동굴절계는 외국산 자동굴절계의 신뢰도 및 정확도와 비교할 수 있는 수준으로 임상성능의 개선이 요구되지만, 자각식 굴절검사를 실시하기 전에 피검자의 굴절이상을 평가하는데 검영법을 대신하여 유용하게 활 용될 수 있는 것으로 사료된다. To analyze the clinical performance of the URK 700 Auto Ref-Keratometer, we measured refractive eπors of 100 eyes of 50 college students using autorefraction and subjective refraction. The measurements were converted to power vectors consisting of h](horizontal component), hz(torsional component) and hJ(vertical component). The test was taken 5 times test and retested respectively with intervals of minimum 30 minutes. The average test-retest of autorefraction was not significantly different in all components. The 95% limits of agreement were -0.83-+0.78D for horizontal component, -0.21-+0.21D for torsional component and -0.82-+0.78D for vertical component. The average discrepancies between subjective refraction 뻐d autorefraction were -0.15:!:0.51D for horizontal component, -0.03:!:0,14D for torsional component and -0,34:!:0.55D for vertical component. The 95% limits of agreement were -1.14 - +0.85D for horizontal component, -0.31 - +0.25D for torsional component and -1.42 - +0.73D for vertical component. The frequency of clinically significant discrepancies between subjective refraction and autorefraction( > 0.5D) were 17% for horizontal component, 0% for torsional component and 23% for vertical component. Therefore, we concluded that URK 700 auto-refractor could be used as a staπing point for subjective refraction instead of retinoscopy, although it is needed to improve the level to those of foreign-made autorefractors in respect of its' repeatability and accuracy.