RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The use of ferrocement in the construction of squat grain silos

        Kıvanc Topcuoglu,Halil Baki Unal 사단법인 한국계산역학회 2016 Computers and Concrete, An International Journal Vol.18 No.1

        In this study, an investigation is made from the statics and economic aspects of the possibility of using the composite material ferrocement on the surfaces of squat cylindrical grain silos. For this purpose, the geometry of two model silos, each of height 5 m and diameter 5 m and 12.5 m, was designed. Five different reinforced plates of 10 and 20 mm thickness were produced to research the most suitable ferrocement plates to be used on the surface of these silos. Most durable reinforcement type for covering the silo surface was determined by pressure and bending tests. Grade 30 and Grade 55 steel plates were also considered for use in covering steel-coated silos. In the statics analysis performed with SAP2000, the least plate thicknesses needed for silos surfaced with Grade 30 and Grade 55 steel were found to be 6.20 mm and 4.70 mm respectively for silos of diameter 5 m, and 6.70 mm and 5.00 mm for silos of diameter 12.5 m. In the economic analysis, it was found that 20 mm thick Type 4 (with a wire diameter of 0.30 mm and a mesh aperture of 2 mm x 2 mm square type) reinforced ferrocement surfacing material was 5.6-6.1 times more economical than Grade 30 steel surfacing material and 4.4-4.7 times more economical than using Grade 55 steel. These results show that ferrocement can be used in place of steel from the point of view both of statics and economy.

      • KCI등재

        Accuracy of virtual models in the assessment of maxillary defects

        Kıvanc Kamburoglu,Sebnem Kursun,Cenk Kılıc,Tuncer Özen 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.1

        Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) 60×60 mm FOV, 0.125 mm3 (FOV60); 2) 80×80 mm FOV, 0.160 mm3 (FOV80); and 3) 100×100 mm FOV, 0.250 mm3 (FOV100). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

      • KCI등재

        Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

        Buket Acar,Kıvanc Kamburoglu,İlkan Tatar,Volkan Arıkan,Hakan Hamdi Çelik,Selcen Yüksel,Tuncer Özen 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.4

        Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman’s rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

      • KCI등재

        Investigation of the Protective Effect of Kefir against Isoproterenol Induced Myocardial Infarctionin Rats

        Handan Mert,Hikmet Yılmaz,Kıvanc Irak,Serkan Yıldırım,Nihat Mert 한국축산식품학회 2018 한국축산식품학회지 Vol.38 No.2

        Thisstudy aims to investigate the protective effects of kefir against myocardial infarction induced by isoproterenol (ISO). The rats were randomly divided into 4 groups, each group consisting of 8 rats. The control group, the kefir group (5 mL/kg/d kefir administered to rats as intra-gastric gavage for 60 d), the ISO group (100 mg/kg ISO was administered to rats, s.c. on 61. and 62. d), and kefir+ISO group (5 mL/kg/d kefir was administered to rats intra gastric gavage for 60 days prior to ISO, 100 mg/kg in twodoses on day 61 and 62). 12 h after the last ISO dose, all rats were decapitated and their blood samples were collected. Cardiac tissue was reserved for histopathological examination. creatine kinase (CK), alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), triglycerides, total cholesterol,very low density lipoprotein (VLDL), low density lipoprotein (LDL), high density lipoprotein (HDL) and glucose were measured by autoanalyzer, whole blood malondialdehyde (MDA), glutathione (GSH) and plasma advanced oxidation protein products (AOPP) levels were measured spectrophotometrically. It was determined that in the group of kefir+ISO, the levels of AST (p

      • SCIESCOPUSKCI등재

        The effect of different adhesive system applications on push-out bond strengths of glass fiber posts

        Mine Betul uctaslı,Hacer Deniz Arısu,Tufan Can Okay,Bagdagul Helvacıoglu Kıvanc 대한치과보철학회 2013 The Journal of Advanced Prosthodontics Vol.5 No.3

        PURPOSE Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess the post retentive potential of a self-adhesive resin cement using different adhesive systems to compare the push-out bond strengths of fiber posts. MATERIALS AND METHODS The post spaces of 56 mandibular premolar roots were prepared and divided into 4 experimental groups and further divided into 2 subgroups according to testing time (n=7). The fiber posts (Rely X Fiber Post) were luted with a self-adhesive resin cement (RelyX Unicem) and one of the following adhesive systems: no adhesive, a total-etch adhesive resin (Single Bond), a two-step self-etch adhesive resin (Clearfil SE Bond) and a one-step self-etch adhesive resin (Clearfil S3 Bond). Each root was cut horizontally, and 1.5 mm thick six root segments were prepared. Push-out tests were performed after one week or three months (0.5 mm/min). Statistical analysis were performed with three-way ANOVA (α=.05). RESULTS Cervical root segments showed higher bond strength values than middle segments. Adhesive application increased the bond strength. For one week group, the total-etch adhesive resin Single Bond showed higher bond strength than the self-adhesive resin cement RelyX Unicem applied without adhesive resin at middle region. For 3 months group, the two-step self-etch adhesive resin Clearfil SE Bond showed the highest bond strength for both regions. Regarding the time considered, Clearfil SE Bond 3 months group showed higher bond strength values than one week group. CONCLUSION Using the adhesive resins in combination with the self-adhesive resin cement improves the bond strengths. The bond strength values of two-step self-etch adhesive resin Clearfil SE Bond improved as time passes.

      • SCIESCOPUSKCI등재

        In Vitro Effects of Rabeprazole on Human Pylorus Tone

        ( Necdet Fatih Yasar ),( Erdal Polat ),( Mustafa Duman ),( Meltem Dagdelen ),( Mehmet Yalcın Gunal ),( Orhan Uzun ),( Cebrail Akyuz ),( Kıvanc Derya Peker ),( Sinan Yol ) 대한소화기기능성질환·운동학회 2015 Journal of Neurogastroenterology and Motility (JNM Vol.21 No.2

        Background/Aims It has been reported that proton pump inhibitors induce relaxation in different types of smooth muscles. The aim of this study is to investigate in vitro effects of proton pump inhibitors on human pylorus muscle. Methods Pyloric sphincters were studied in 10 patients who were operated for stomach cancer. In isolated organ bath, control and response to rabeprazole were recorded following contraction with carbachol. During the treatment experiment, while distilled water was applied during the control experiment in every 5 minutes, rabeprazole was administered in every 5 minutes at doses of 10-6, 10-5, 10-4, and 10-3 M respectively. Contraction frequencies, maximum contraction values and muscle tones were measured. Results The contraction frequencies in the control group were greater than the rabeprazole group in the second, third and fourth intervals while the maximum contraction values in the rabeprazole group were lower in the fourth interval. Even though muscles tones were not different in both groups during all intervals, it was remarkable that the muscle tone was significantly decreased in the rabeprazole group during the fourth interval compared to the first and second intervals. Conclusions In the present study, high doses of rabeprazole reduced contraction frequencies, maximum contraction values, and muscle tone of human pylorus. (J Neurogastroenterol Motil 2015;21:217-221)

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼