RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Accuracy of virtual models in the assessment of maxillary defects

        Kamburoglu, Kivanc,Kursun, Sebnem,Kilic, Cenk,Ozen, Tuncer Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.45 No.1

        Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

      • KCI등재

        Accuracy of virtual models in the assessment of maxillary defects

        Kıvanc Kamburoglu,Sebnem Kursun,Cenk Kılıc,Tuncer Özen 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.1

        Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) 60×60 mm FOV, 0.125 mm3 (FOV60); 2) 80×80 mm FOV, 0.160 mm3 (FOV80); and 3) 100×100 mm FOV, 0.250 mm3 (FOV100). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

      • SCOPUSKCI등재

        Florid osseous dysplasia in a middle-aged Turkish woman: A case report

        Onder, Buket,Kursun, Sebnem,Oztas, Bengi,Baris, Emre,Erdem, Erdal Korean Academy of Oral and Maxillofacial Radiology 2013 Imaging Science in Dentistry Vol.43 No.3

        Florid osseous dysplasia (FOD) is an uncommon, benign, cemento-osseous lesion of the jaws. The etiology of FOD is still unknown. It is often asymptomatic and may be identified on routine dental radiographs. The classic radiographic appearance of FOD is amorphous, lobulated, mixed radiolucent/radiopaque masses of cotton-wool appearance with a sclerotic border in the jaws. In our case the lesion was found incidentally on routine periapical radiographs taken for restored teeth and edentulous areas. For further and detailed examination, a panoramic radiograph and cone-beam computed tomograph (CBCT) were taken. The panoramic radiograph and CBCT revealed maxillary bilateral and symmetrical, non-expansile, well-defined, round, radiopaque masses in contact with the root of the maxillary right second molar and left first molar teeth. Our aim in presenting this case report was to highlight the importance of imaging in diagnosis of FOD.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼