http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
주경문,천근영,이정석,Joo, Kyung Mun,Cheon, Keun Young,Lee, Jeong Seok 한국압력기기공학회 2009 한국압력기기공학회 논문집 Vol.5 No.1
There is extensive tubing pipe in the nuclear power plant under high temperature and pressure. Erosion and corrosion defects are expected on this tubing pipe due to environmental and mechanical factors. In this study, Guided Ultrasonic Wave technique was applied to detect defects. The technique explores the advantages of the Guided Ultrasonic Wave method that inspects along the wall of the pipe and can travel long distances, providing rapid collection of data. This paper presents a case study of the Guided Ultrasonic Wave testing of 3/8" tubing pipe. This study offers to understand detected signals through correlation between amplitude and depth of defects.
증기발생기 전열관 외면 축균열 건전성 평가를 위한 비파괴검사 크기 측정 평가
주경문,홍준희,Joo, Kyung-Mun,Hong, Jun-Hee 한국비파괴검사학회 2015 한국비파괴검사학회지 Vol.15 No.1
최근 국내 증기발생기 Alloy 600HTMA 전열관의 관 지지판 부위 외면 축균열 결함의 생성이 지속적으로 증가하고 있다. 이로 인하여 증기발생기가 설계수명 이전에 조기 교체되었으며 또는 교체 예정이다. 전열관 외면 축균열은 건전성 관리에 가장 위협이 되는 요소이므로 정밀한 건전성 평가가 요구된다. 와전류검사(ECT, eddy currunt testing)는 주기적으로 수행되어 지며 이 결과는 건전성 평가 입력 자료로 활용된다. ECT 검사시스템의 신뢰성은 검사기술과 평가자 기량에 의존하며, NDE 시스템 성능을 보여주는 지수는 열화탐지와 크기 측정 오차이다. 본 연구에서는 국내 평가자 성능이 반영된 크기 측정 오차와 그리고 최적의 균열 크기 측정 방법을 제시하였다. 실험은 국내 각기 다른 5개 회사에서 10명의 평가자가 참여한 다자간 비교시험의 결과를 사용하여 이루어졌다. 실험 결과 분석은 파괴검사 결과값과 비파괴검사로 측정된 값의 상관관계를 회귀분석을 통하여 이루어졌다. Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.
가압기 히터슬리브 용접부 PWSCC 검출을 위한 유도초음파 특성 평가
주경문,문용식,정우근,Joo, Kyung-Mun,Moon, Yong-Sig,Chung, Woo-Geun 한국압력기기공학회 2011 한국압력기기공학회 논문집 Vol.7 No.2
Although many defects in PZR heater sleeve have been reported continually from operating experiences in oversea nuclear power plant, utilities get into difficulties in finding appropriate methods for diagnostics of the components due to the limited access or high radiation problems. Recently, as an alternative, diagnostics using Guided Wave Testing(GWT) are proposed and the attention of the methods has been growing gradually because of their long range inspection capability. This study is to investigate the effectiveness of GWT to detect PWSCC in welding points of PZR heater sleeve. Moreover, mode sensitivity analysis of GWT and optimal frequency for the diagnostics of PWSCC are presented by testing the mock-ups specimens that contain artificial flaws.