http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김용대(YongDae Kim) 고려대학교 보건과학연구소 2005 보건과학논집 Vol.31 No.1
Recently, The cancer patient"s are increased by medical examination.<BR> So, The government going into action for the preventation of cancer.<BR> Especially, The stomach cancer is the first rank of occurrence in Korea and the medical examination of stomach is increased. But we don"t know a patient"s exposure dose during the study of UGI series. The purpose of this study is to get the patient"s exposure dose data by the Bit system and the NDD method and suggest the reduction of the patient"s exposure dose.<BR> The results as follow<BR> 1. The patient"s total exposure dose are 17R(Bit system), 16.5R(NDD Method) on the average.<BR> 2. The plan of the reduction is concerned with time, filtration, technique, distance, X-ray generator etc.
김용대(Yongdae Kim) 한국정보보호학회 2019 情報保護學會誌 Vol.29 No.5
본 고는 필자가 지난 8년 간 다양한 이동통신 취약점 연구를 했던 경험을 바탕으로 5G 이동통신 보안의 미래에 대하여 예측하는 것을 목적으로 한다. 이를 위하여 기존 네트워크 보안과 다른 이동통신 기술의 특수성, 이동통신 보안의 기술적 어려움에 대하여 분석을 하고, 실제로 취약점 분석을 했던 경험을 바탕으로 5G 이동통신 보안의 미래에 대하여 예측하고자 한다.
금속 외팔보에 접착된 박막 실리콘 스트레인 게이지의 제작 및 성능 평가
김용대(Yongdae Kim),김영덕(Young Deok Kim),이철섭(Chul Sub Lee),권세진(Sejin Kwon) 대한기계학회 2010 大韓機械學會論文集A Vol.34 No.4
금속은 가공성이 우수하기 때문에 다양한 형태의 구조물이나 격막을 제작할 수 있다. 이런 금속구조물이나 격막에 민감도가 월등히 우수한 실리콘 스트레인 게이지를 적용할 경우 그 응용 범위가 다양해질 수 있다. 이에 금속구조물에 다결정 실리콘 스트레인 게이지를 접착한 형태의 센서를 제안하였다. 실리콘 기판을 이용해 박막형 다결정 실리콘 스트레인 게이지를 제작하기 위한 제작공정을 확립하였으며, 제작된 실리콘 스트레인 게이지를 금속 변형부 위에 접착하기 위한 접착공정을 확립하였다. 이후 금속 외팔보에 실리콘 스트레인 게이지를 글래스 프릿 접착하여 성능평가를 실시하였다. 성능평가 결과 게이지팩터는 34.0의 값을 가졌으며, TCR(Temperature Coefficient of Resistance)은 -328 ppm/℃의 값을 가졌다. In this paper, we propose a sensor design by using a polysilicon strain gauge bonded to a metal diaphragm. The fabrication process of the thin polysilicon strain gauges having thicknesses of 50 μm was established using conventional MEMS technologies; further, the technique of glass frit bonding of the polysilicon strain gauge to the stainless steel diaphragm was established. Performance of the polysilicon strain gauge bonded to the metal cantilever beam was evaluated. The gauge factor, temperature coefficient of resistance (TCR), nonlinearity, and hysteresis of the polysilicon strain gauge were measured. The results demonstrate that the resistance increases linearly with tensile stress, while it decreases with compressive stress. The value of the gauge factor, which represents the sensitivity of strain gauges, is 34.0; this value is about 7?15 times higher than the gauge factor of a metal-foil strain gauge. The resistance of the polysilicon strain gauge decreases linearly with an increase in the temperature, and TCR is -328 ppm/℃. Further, nonlinearity and hysteresis are 0.21 % FS and 0.17 % FS, respectively.
위상 보상된 속도 센서를 이용한 6자유도 능동 방진 시스템의 개발
김용대(Yongdae Kim),김상유(Sangyoo Kim),박기환(Kyihwan Park) 대한기계학회 2009 大韓機械學會論文集A Vol.33 No.11
Magnetic force driven six degree-of-freedom active vibration isolation system is developed. The velocity sensor using an electromagnetic principle that is commonly used in the vibration control is investigated since its phase lead characteristic causes an instability problem for a low frequency vibration. A lag-type compensator is adopted to reduce the phase lead and the stability test is performed by using a Bode analysis. The performance of the AVIS is validated by comparing with the passive isolation system by using the frequency responses.