TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석
홍원표(Won-Pyo Hong) 한국조명·전기설비학회 2015 조명·전기설비학회논문지 Vol.29 No.1
Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.
김동일(Kim Dongil),이병호(Lee Byeongho) 한국태양에너지학회 2020 한국태양에너지학회 논문집 Vol.40 No.1
Building energy consumption generally depends on living patterns of residents and outdoor air temperature changes. Although outdoor air temperature changes effect on building energy consumption, there is no calibration method for the comparison before and after Green Remodeling or BEMS installation etc., Big data of building energy consumption are collected and managed by 『National Integrated Management System of Building Energy』 in Korea, and they are utilized for the development of a calibration method for individual buildings as shown as the calibration method for small-area building stocks in the previous research. This study aims to develope a calibration method using big data of building energy consumption of individual buildings and outdoor air temperature changes, and to propose application of appropriate calibration methods for individual buildings or small-area building stocks according to the calibration purpose and conditions.
초고층 공동주택의 세대별 냉난방부하 시뮬레이션 결과 및 에너지 실사용량과의 비교 분석
서혜수(Suh,Hye-Soo),김병선(Kim,Byung-Seon) 한국태양에너지학회 2011 한국태양에너지학회 논문집 Vol.31 No.4
Apartment Housing has been increasing steadily, particularly our current super high-rise apartment houses that represent the culture has become a trend in Korea. These super high-rise apartment houses’ curtain wall system increases heating and cooling loads, it is expected to vary by each unit’s thermal properties. In this study, measured indoor environment and energy simulation results were compared to actual energy consumption. As a result, the various factors that affect heating and cooling loads, such as direction, plan type and glazing area, influence each unit’s load characteristic. In particular, according to the electricity costs savings behavior, the occupant’s thermal discomfort is expected to be large in summer. Therefore, to reduce heating and cooling load for each unit requires a reasonable plan.
에너지 평가 프로그램을 이용한 공동주택 부대시설 설계사례
홍구표(Goo-Pyo Hong),박철용(Cheol Yong Park),박윤섭(Yoon Sup Park) 대한설비공학회 2010 대한설비공학회 학술발표대회논문집 Vol.2010 No.6
Energy consumption of building is very hot topic recently. It becomes more and more important to look for efficient ways of energy consumptoion. It is selected a community center to low energy design. The project uses eQuest, a simulation software tool, for evaluating building energy. First it is evaluated the design to comply with the code, Second the usual design as ALT-1. They are compared the monthly load components and studied what's components affected. Accordingly, the performance of insulation and window system is improvement and photovolatic power generation systems are installed. That is the low energy design as ALT-2. Heating energy consumption is reduced 57%, Cooling energy consumption is reudced 24% through the case study as ALT-2.
김종민 대한건축학회지회연합회 2009 대한건축학회연합논문집 Vol.11 No.1
This study examined the effect of green roof and respects the supply promotion of green roof from researched. The simulation make green roof in virtue building in followed in change roof area in seven city (Seoul, Incheon, Daejeon, Daegu, Gwangju Ulsan, Busan). The city total green roof examines an application effect in house space and commercial space. In seven city each city building coverage decides the application roof area in house space and commercial space. Applied a simulation program Energy plus v2.2 from resultant contents cooling load in heating load and energy consumption analyzes the effect of the green roof which follows. Method of research applied a simulation program at roof area(330㎡, 990㎡, 1650㎡, 3300㎡) four kind of case gives. Also, the ho use space and commercial space in city sets at applied simulation program in the one building. This study get the data of cooling load, heating load and energy change in two conditions, One is the data without green roof and another is the date with green roo f. As a result of the simulation, roof area affects the cooling load, heating load and energy consumption. cooling load, heating load and energy consumption is decreasing in the condition of broad green roof.
사무용 건축물의 차양 설치 비율에 따른 냉난방 에너지 소요량 분석에 관한 연구
이진현(Jin-Hyun Lee),신지현(Ji-Hyun Shin),김선숙,조영흠(Young-Hum Cho) 대한설비공학회 2016 대한설비공학회 학술발표대회논문집 Vol.2016 No.6
If you do not have well-established plans for natural light, it is likely to inhibit efficiency and be offensive to the people. For people, the natural light is needed to ensure proper illumination secure and energy saving through the use of solar energy. It is awning that allows to effectively control the solar radiation. In this study, we intends to evaluate the effect on energy consumption by the application of shading device. For these purpose we supposed the models which are composed of the several rooms that have enough size of windows. Then we analyzed the energy consumption according to 2 criteria using ECO-2 program. First, Ratio of awning installation. Second, awning length and installation rate. The results of this study are follows. : 1) A building that get high point using certificate regulation of environment friendly building is not related to eco-friendly building. 2) As the length of shade is longer, the amount of cooling energy consumption is lower.
도시열섬현상 저감을 위한 PCM(Phase Change Material)의 단열성능 시뮬레이션 분석
이효은(Lee, Hyo Eun),양영권(Yang, Young Kwon),정민희(Chung, Min-Hee),박진철(Park, Jin Chul) 대한건축학회 2017 大韓建築學會論文集 : 構造系 Vol.33 No.6
This study aimed to analyze the Thermal Insulation Performance of the PCM Cool Roof System, which is being developed for mitigating the Urban Heat Island Effect. We compared the performance of common insulation material versus that of PCM, both applied on a standard roof model. We found that PCM had less cooling energy consumption compared to common insulation, whereas common insulation had less heating energy consumption. The annual total energy consumption was found to be lower when using PCM. Therefore, we conclude that the PCM Cool Roof System has insulating capacity comparable to that of common insulation.
도시열섬현상 저감을 위한 PCM(Phase Change Material)의 단열성능 시뮬레이션 분석
이효은(Lee, Hyo Eun),양영권(Yang, Young Kwon),정민희(Chung, Min-Hee),박진철(Park, Jin Chul) 대한건축학회 2016 대한건축학회 학술발표대회 논문집 Vol.36 No.2
This study aimed to analyze the Thermal Insulation Performance of the PCM Cool Roof System, which is being developed for mitigating the Urban Heat Island Effect. We compared the performance of common insulation material versus that of PCM, both applied on a standard roof model. We found that PCM had less cooling energy consumption compared to common insulation, whereas common insulation had less heating energy consumption. The annual total energy consumption was found to be lower when using PCM. Therefore, we conclude that the PCM Cool Roof System has insulating capacity comparable to that of common insulation.
대형 판매시설의 최적 에너지 절약을 위한 설비 운영시스템 개선 방안에 관한 연구
김정석,이훈,오민석,김회서 한국건축친환경설비학회 2013 한국건축친환경설비학회 논문집 Vol.7 No.2
Reduction of energy in buildings by efficient management of energy is consistent with long/short-term national policies and the following economic effects are expected. In this study, I suggested the energy management system and its assessment method which are objective indicators of cost of building maintenance. Related with "Building Energy Efficiency Rating System", I did a basic research on energy-saving measure is applicable to the office building while its remodeling and operating. I also gave a building energy-saving measure to upgrade the building energy efficiency rating. And a certain size and same utilization of three places in an office building were selected to search the equipment system,automatic control and usage of energy by site survey for the purpose of estimating the building energy efficiency rating. In addition, I found out the problem of the operation and design stage of the office building and gave a measure of upgrading the building energy efficiency rating according to the amount of energy savings with building envelop replacement and operation of equipment system.
대형 판매시설의 최적 에너지 절약을 위한 설비 운영시스템 개선 방안에 관한 연구
김정석(Kim Jung-Seok),이훈(Lee Hoon),오민석(Oh Min-Seok),김회서(Kim Hway-Suh) 한국건축친환경설비학회 2013 한국건축친환경설비학회 논문집 Vol.7 No.3
Reduction of energy in buildings by efficient management of energy is consistent with long/short-term national policies and the following economic effects are expected. In this study, I suggested the energy management system and its assessment method which are objective indicators of cost of building maintenance. Related with "Building Energy Efficiency Rating System", I did a basic research on energy-saving measure is applicable to the office building while its remodeling and operating. I also gave a building energy-saving measure to upgrade the building energy efficiency rating. And a certain size and same utilization of three places in an office building were selected to search the equipment system, automatic control and usage of energy by site survey for the purpose of estimating the building energy efficiency rating. In addition, I found out the problem of the operation and design stage of the office building and gave a measure of upgrading the building energy efficiency rating according to the amount of energy savings with building envelop replacement and operation of equipment system.