http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
한승오,박승만,Han, Seungoh,Park, Seung-Man 한국군사과학기술학회 2016 한국군사과학기술학회지 Vol.19 No.6
Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.
스크류 로드 작업 균일도 향상을 위한 견인력 및 스프링백 영향도 분석
한승오(Seungoh Han),강대영(Dae Young Kang),유형민(Hyung Min Yu),김영빈(Young Bin Kim),김수인(Su In Kim),권지운(Jiwoon Kwon),조용근(Yong Geun Cho) 대한기계학회 2021 대한기계학회 춘추학술대회 Vol.2021 No.4
스크류 로드는 비트에서 굴착 된 흙을 지상으로 이송 배출하는 역할을 하는 천공기의 핵심 부품이다. 균일한 품질과 장시간의 신뢰성 확보가 가능한 내구성이 핵심요소이나 현재까지의 스크류 조립은 작업자의 노하우에 의지하여 제작되어 왔다. 이와 같이 용접되어 제작된 스크류의 잔류 응력은 스크류 내구성에 부정적인 결과를 초래해왔다. 이러한 문제를 해결하기 위해 다양한 스크류 제작에 필요한 인장력을 유한요소해석을 통해 규정하고, 이를 기반으로 각 스크류를 제작하기 위한 인장력을 선정할 수 있는 실험식과 자동설정 알고리즘을 제시하였다. 또한 이에 따른 잔류응력을 최소화할 수 있도록 스크류 로드에 발생하는 스프링백의 영향을 유한요소해석을 통해 분석하였다. 본 연구결과는 스크류 로드 내구성을 향상시키기 위해 제조 공정의 기초 자료로 활용할 예정이다. The screw rod is a key part of the drilling machine that serves to transport and discharge the soil excavated by the bit. Durability, which enables uniform quality and long-term reliability, is a key factor, but screw assembly so far has been built based on the know-how of the operator. The residual stress of these welded and manufactured screw rods has had negative consequences for screw durability. To solve this problem, we define the tensile force required for the production of various screws through finite element analysis, and based on this, we provide an empirical formula and automatic setup algorithms that can select the tensile force to produce each screw rod. In addition, the effects of spring back on the screw rods were analyzed through finite element analysis to minimize residual stress. The results of this study will be used as a basic data for the manufacturing process to improve screw rod durability.
한승오(Seungoh Han),김일중(Il-Jung Kim),구경완(Kyung-Wan Koo) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
MEMS 기술을 이용한 다양한 센서의 개발과정에서 신뢰성 확보는 매우 중요한 문제이며, 여러 가지 신뢰성 항목 가운데 낙하시험은 가장 기본이 되는 항목이다. 단시간 내에 낙하에 대한 내충격성을 확보하는 MEMS 센서를 개발하기 위해 본 논문에서는 FEA와 high-level 모델을 결합한 낙하시험 모의진단법을 제안하였다. 제안된 모의진단법을 통해 MEMS 소자에서의 최대응력과 응력분포, 최대변위, 그리고 낙하시의 과도응답과 오신호 등의 결과를 확보할 수 있으며 이들을 토대로 MEMS 소자에서의 취약부위를 파악하고 이를 보완할 수 있으며 낙하시의 오동작을 제거하도록 신호처리 회로 등을 보완할 수도 있을 것이며 이를 통해 단시간 내에 최소의 비용으로 내충격성을 확보한 MEMS 센서를 개발하는 것이 가능해질 것이다.
복합장 해석에 의한 전자력 구동방식의 마이크로미러 설계
한승오(Seungoh Han),김병민(Byoungmin Kim),박정호(Jungho Pak) 대한전기학회 2010 전기학회논문지 Vol.59 No.2
A micromirror for a laser display system actuated by the electromagnetic force induced by the surface coil and the permanent magnet was designed and analyzed through the coupled physics analyses incorporating the electromagnetics, mechanics, and electrothermal analysis because the mechanical rotation of the micromirror is driven by the electromagnetic driving force. The proposed micromirror has two torsion beams to sustain the mirror plate which has surface coils on the top and the two permanent magnets exists on both sides of the micromirror for an external magnetic field source. The designed micromirror has the resonant frequency of 3.82㎑. When the magnetic field of the permanent magnet is 0.4T, the coil has 4 turns, and the current density of coil is 3.6A/㎟, the estimated z axis displacement of the mirror plate edge is 0.23㎜ which corresponds to the rotation angle of 14.2˚. When considering the joule heating in the current-carrying coil, the maximum temperature of the mirror plate is obtained as 300.045K, which induces the negligible changes in the rotation angle and the resistance of the coil.
진정호,한승오,양희원,박승만,Jin, Jung-Ho,Han, Seungoh,Yang, Hee Won,Park, Seung-Man 한국광학회 2015 한국광학회지 Vol.26 No.1
섬광의 복사온도를 측정 할 수 있는 장치를 설계하고 제작하였다. 본 논문에서는 중 원적외선 영역에서 광원의 스펙트럼 복사휘도(spectral radiance)를 측정하여 두 영역의 복사휘도 비로부터 섬광의 복사온도를 구할 수 있는 장치를 설계 및 제작하였다. 중 원적외선 영역에서 파장에 따른 복사휘도를 측정하기 위하여 광학적 대역 투과필터로 입사광을 파장에 따라 분할하고 각각의 파장으로 분할된 광을 동시에 적외선 검출기로 검출하여 입력광의 파장에 따른 복사휘도를 측정하였다. 제작된 장비로 섬광의 온도를 측정한 결과 1393K와 1455K의 온도를 얻었다. 제작된 복사온도 측정 장치는 섬광의 광원 정보를 파악하는데 중요하게 활용될 수 있으며, 섬광의 효과를 위한 M&S에 활용될 수 있다. The design and implementation of a radiative temperature measurement system for a flash light are carried out. Since a massive amount of energy is emitted within a very short time, it is impossible to measure the temperature of a flash with a conventional method. It is also irrelevant to measure one with an optical noncontact method. In this paper, a radiative temperature measurement system using the ratio of spectral radiances over mid- and long-wavelength infrared (IR) is designed and implemented. The implemented system utilizes optical bandpass filters to divide the wavelengths within the mid- and long-wavelength IR ranges, and pyroelectric IR detectors to measure the incident optical power of each wavelength-divided channel. It is shown that the measured radiative temperature of a flash is in the range of 1393 to 1455 K. This temperature-measurement system can be utilized to obtain information about the spectral radiance of a flash as a light source, which is of crucial importance to approaching the modeling and simulation of the various effects of a flash.
마이크로 볼로미터 초점면 배열에서 전기-열적 피드백 현상이 신호에 미치는 영향
박승만(Seung-man Park),한승오(Seungoh Han) 대한전기학회 2012 전기학회논문지 Vol.61 No.12
In this paper, the analytical models for the electrothermal feedback of a μ-bolometer focal plane array(FPA) are proposed and applied to the conceptually designed FPA to investigate the electrothermal feedback effect on bolometer FPA signal. The temperature and resistance change of the μ-bolometer by the electrothermal feedback(ETF) model are increased upto 20 and 35.7 % of those of no feedback case, respectively, while those by the effective thermal conductance(ETC) model increased 8.5 and 15.1 %. The integration current and output voltage of a CTIA used as an column amplifier of FPA are also increased upto 41.6 and 32.4 % by the ETF model, while increased upto 17.2 and 13.5 % by the ETC model. The proposed models give more accurate temperature change, accordingly larger signal than no feedback considering case. Electrothermal feedback effect should be considered to design a high performance and high density μ-bolometer FPA. The proposed models are very useful to investigate the transient thermal analysis, also considered to be useful to predict the responsivity and dynamic range of μ-bolometer FPAs.