http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Sang-yeop Shin,신희석,윤철호,이은신,오민균,A Ram Kim,Jong Moon Park,Jun-Hwa Shin 대한재활의학회 2011 Annals of Rehabilitation Medicine Vol.35 No.5
Objective To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. Method The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Physical measurements included thigh-foot angle (TFA) and bimalleolar angle (BMA). 3D-CT measurement and physical measurement were performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coeffi ciency (ICC). Th e relationship between radiological and physical examination was calculated by Spearman correlation coefficient. Results The 3D-CT measures for tibial torsion were reliable within individual raters and between different raters. However, physical measures for tibial torsion were reliable within an individual rater but not reliable between raters. The 3D-CT measures by any proximal reference axis were more reliable within a rater and between raters than physical measurements. There was no signifi cant impact introduced by the selection of the proximal reference axis. The correlation coeffi ciency between 3D-CT and physical measurement methods was low. Conclusion Because the 3D-CT measurements for tibial torsion are more reliable than physical measurements, we recommend that accurate diagnosis of internal tibial torsion should be detected by using 3D-CT measurements. Also, considering the disadvantages of radiological measurements, physical measurement may be used for short term follow-up by same raters, as intra-rater reliability is relatively good.
Demonstration Test of Full System Decontamination and Its Operational Review
Sung Hyun Lee,Jung-Hyun Lee,Ju-Hyeon Park,Sung-Sik Yoon,Jeong-Yeop Cha,Seung-Ki Lee,Sung-Su Kim,Chung-kyu Lee,Ki-Chul Kim 한국방사성폐기물학회 2022 한국방사성폐기물학회 학술논문요약집 Vol.20 No.2
In this research, KPS manufactured Full System Decontamination (FSD) equipment, which is consisted of Oxidizing Agent Manufacturing System (OAMS), Chemical Injection System (CIS), RadWaste Treatment System (RWTS), Chemical Waste Decomposition & Treatment System (CWDS) and conducted demonstration test to prepare Decontamination and Decommissioning (D&D) project of Kori nuclear power plant in Korea. Each equipment of FSD was modularized due to the limited size of equipment hatch of Kori nuclear power plant. To simulate the expected circumstances in nuclear power plant such as usage of heater or position of each equipment, additional equipment was used. The chemical concentration and flow rate of process water for FSD were used as mentioned in the previous study by KHNP CRI. FSD was conducted for three cycles and each cycle was consisted of oxidation, reduction, chemical decomposition and purification. Oxidation and reduction process were conducted at 90°C. Chemical decomposition and purification process were conducted at 40°C due to the damage of UV lamp and IX by the heat. Total volume of process water for FSD demonstration test was 2.5 m2. KPS conducted decontamination performance review by calculating thickness reduction and weight loss of installed specimen. Operational review was conducted as if FSD test was conducted in the field based on the result of demonstration test. One of the most prioritized features is the workers’ safety. Also, the appropriate position of equipment needs to be considered to meet the required specification of component.
Sang June Park,Moonoh Kim,Jun-Yeop Lee,Hang-Rae Cho,Suil Bang 한국방사성폐기물학회 2022 한국방사성폐기물학회 학술논문요약집 Vol.20 No.1
Safety for the radioactive waste disposed of in the disposal facility should be secured through safety assessment in consideration of the various situations. In this study, the influence and correlation of EDTA and ISA, which are the factors that can impede the safety of the disposal facility, were analyzed using the PHREEQC computational code. Thermodynamic database (TDB) of Andra, specific ion interaction theory (SIT) model as ionic strength correction model, radionuclides (Ni, Am, Pu) were adopted to perform the calculation on the distribution of chemical species by pH. According to the results, EDTA dominated the system and the effect of ISA is relatively small for the distribution of the chemical species of divalent and trivalent cations in neutral and weak base conditions. In the case of the tetravalent cations, the effect of ISA increased compared to the previous case especially in the strong base conditions. In conclusion, EDTA has a more significant effect on the system than ISA under the environment of the domestic disposal facility. Furthermore, when EDTA and ISA are present simultaneously in the system, the effects of two materials are inversely proportional and this characteristic should be considered during the safety assessment.
Sung-Soo Park,Hee-Je Kim,Tong Yoon Kim,Joon yeop Lee,Jong Hyuk Lee,Gi June Min,Silvia Park,Jae-Ho Yoon,Sung-Eun Lee,Byung-Sik Cho,Ki-Seong Eom,Yoo-Jin Kim,Seok Lee,Dong-Wook Kim 대한혈액학회 2021 Blood Research Vol.56 No.3
Background Allogeneic hematopoietic stem cell transplantation (alloSCT) is a potentially curative treatment option for acute leukemia. We aimed to identify the comorbidity factors affecting survival outcomes after alloSCT and develop a new comorbidity index tool for predicting overall survival (OS). Methods A Korean nationwide cohort of 3,809 adults with acute leukemia treated with alloSCT between January 2002 and December 2018 was analyzed as the development cohort. A retrospective cohort comprising 313 consecutive adults with acute leukemia who underwent alloSCT between January 2019 and April 2020 was analyzed as the validation cohort. Results In the development cohort, advanced age, male sex, and comorbidities such as previous non-hematologic malignancy, hypertension, and coronary or cerebral vascular disease were significantly related to poor OS. Subsequently, a new comorbidity scoring system was developed, and risk groups were created, which included the low-risk (score ≤0.17), intermediate-risk (0.17< score ≤0.4), high-risk (0.4< score ≤0.55), and very high-risk (score >0.55) groups. The 1-year OS rates were discriminatively estimated at 73.5%, 66.2%, 61.9%, and 50.9% in the low-risk, intermediate-risk, high-risk, and very high-risk groups in the development cohort, respectively (P<0.001). The developed scoring system yielded discriminatively different 1-year OS rates and 1-year incidence of non-relapse mortality according to the risk group (P=0.085 and P=0.018, respectively). Furthermore, the developed model showed an acceptable performance for predicting 1-year non-relapse mortality with an area under the curve of 0.715. Conclusion The newly developed predictive scoring system could be a simple and reliable tool helping clinicians to assess risk of alloSCT in adults with acute leukemia.
Park, Chul-Min,Ahn, Won-Ju,Jo, Woong-Kyu,Song, Jin-Hun,Oh, Chang-Yeop,Jeong, Young-Shin,Chung, Min-Chul,Park, Kwon-Pil,Kim, Ki-Joong,Jeong, Woon-Jo,Sohn, Bo-Kyun,Jung, Sang-Chul,Lee, Do-Jin,Ahn, Byeon American Scientific Publishers 2015 Journal of Nanoscience and Nanotechnology Vol.15 No.1
<P>The greenhouse effect of carbon dioxide (CO2) has been recognized as one of the most serious problems in the world. Conversion of CO2 to methyl alcohol (CH3OH) was studied using catalytic chemical methods. Honeycomb-typed monolith used as catalyst support was 400 cell/inch2. Pretreatment of the monolith surface was carried out by thermal treatment and acid treatment. Monolith-supported nanosized CuO-ZnO catalysts were prepared by wash-coat method. The prepared catalysts were characterized by using SEM, TEM, and XRD. The catalytic activity for CO2 hydrogenation to CH3OH was investigated using a flow-type reactor with varying reaction temperature, reaction pressure and contact time. Conversion of CO2 was increased with increasing reaction temperature, but selectivity to CH3OH was decreased. Optimum reaction temperature was about 250 degrees C under 20 atm. Because of the reverse water gas shift reaction.</P>
Development of Welsh Onion Harvester for Tractor
( Sung Ha Hong ),( Kyou Seung Lee ),( Yong Jin Cho ),( Won Yeop Park ) 한국농업기계학회 2014 바이오시스템공학 Vol.39 No.4
Purpose: To ascertain the increase of the farm income that predominantly relies on human resources by mechanizing Welsh onion harvesting, a tractor-mounted Welsh onion harvester was developed in this study. Method: An experiment for evaluating harvesting performance was performed for the developed Welsh onion harvester in an actual Welsh onion farm. The harvest performance was evaluated at the tractor running speeds of 5.0 cm/s, 11.4 cm/s and 15.8 cm/s, by comparing the operating efficiency, harvest rate, and damage rate of the Welsh onion harvester. Results: The performance of the harvester was rated as very good, with a 100% harvest rate, regardless of tractor running speed. Furthermore, it is shown that work efficiency of the harvester is expected to increase as the running speed increases. Nonetheless, the damage rate of the harvested Welsh onions at running speeds 5.0 cm/s, 11.4 cm/s, and 15.8 cm/s, increased correspondingly and proportionally to speeds from 4.55% to 6.53% and to 11.29%. The residual amount of soil on the harvested Welsh onions was about 0.24% of their weight showing excellent soil-removal performance of the harvester. Conclusion: The developed Welsh onion harvester is believed to improve the labor productivity and cultivation environment of Welsh onion farmhouses by the mechanization of the harvesting process that is currently associated with the largest amount of labor hours.
Preliminary Design and Implement Plan of Kori Unit 1 Full System Decontamination Project
Sung Hyun Lee,Jung-Hyun Lee,Ju-Hyeon Park,Jeong-Yeop Cha,Seung-Ki Lee,Sung-Su Kim,Chung-Kyu Lee,Ki-Chul Kim 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.2
KEPCO KPS is the contractor for the full system decontamination (FSD) of Kori Unit 1 and under preparation such as modification, lay out for equipment installation, setting up tie-in/out point for chemical injection and way to pressurize the system, of its successful performance. In this research, KPS introduced how KPS has designed and prepared for the FSD project and how will the chemical decontamination process be implemented. As described in the previous research, chemical decontamination process is planned to be conducted for three cycles and each cycle is consisted of oxidation, reduction, decomposition, and purification. Oxidation and reduction process were conducted at 90°C. Chemical decomposition and purification process were conducted at 40°C due to the damage of IX by the heat. If the decontamination result does not meet the target DF and the dose rate, additional cycle can be conducted. Expected volume of process water for FSD is 200 m3. Three systems have been designated as decontamination targets: reactor coolant system (RCS), residual heat removal system (RHRS), chemical volume control system (CVCS). For the steady flow rate, existed plant equipment such as reactor coolant pump (RCP) will be operated and modifications on some components will be conducted. Due to the limited space for installation, decontamination equipment and other resources are distributed to three different places. KPS designed the layout of equipment installed inside the containment vessel. The layout contains the information of shielding for highly radiated equipment such as IX and filter skid.