RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Serum Insulin-Like Growth Factor Binding Protein 7 as a Potential Biomarker in the Diagnosis and Prognosis of Esophagogastric Junction Adenocarcinoma

        Can-Tong Liu,Yi-Wei Xu,Hong Guo,Chao-Qun Hong,Xin-Yi Huang,Yu-Hao Luo,Shi-Han Yang,Ling-Yu Chu,En- Min Li,Yu-Hui Peng 거트앤리버 소화기연관학회협의회 2020 Gut and Liver Vol.14 No.6

        Background/Aims: Esophagogastric junction adenocarcinoma (EJA) is a malignant tumor associated with high morbidity and has attracted increasing attention due to a rising incidence and low survival rate. Pathological biopsy is the gold standard for diagnosis, but noninvasive and effective tests are lacking, resulting in diagnoses at advanced stages. This study explored the diagnostic value of insulin-like growth factor binding protein 7 (IGFBP7) in EJA. Methods: A total of 120 EJA patients and 88 normal controls were recruited, and their serum levels of IGFBP7 were measured by enzymelinked immunosorbent assay. Receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic value, and Pearson chi-square analysis was used to evaluate the correlation between IGFBP7 and clinical parameters. Kaplan- Meier survival analysis was carried out to assess the effect of IGFBP7 on overall survival (OS). Results: The levels of IGFBP7 were higher in both early- and late-stage EJA patients than in normal controls (p<0.001). The area under the ROC curve for EJA patients was 0.794 (95% confidence interval [CI], 0.733 to 0.854), with a cutoff value of 2.716 ng/mL, a sensitivity of 63.3% (95% CI, 54.0% to 71.8%) and a specificity of 90.9% (95% CI, 82.4% to 95.7%). For the diagnosis of early-stage EJA, the same cutoff value and specificity were obtained, but the sensitivity of IGFBP7 was 54.3% (95% CI, 36.9% to 70.8%). Patients with low IGFBP7 protein expression had lower OS than those with high expression (p=0.034). The multivariate analysis showed that IGFBP7 is an independent prognostic factor for EJA (p=0.011). Conclusions: Serum IGFBP7 acts as a potential diagnostic and prognostic marker for EJA.

      • KCI등재

        Simulation analysis and evaluation of decontamination effect of different abrasive jet process parameters on radioactively contaminated metal

        Zhong Lin,Deng Jian,Zuo Zhe-wen,Huang Can-yu,Chen Bo,Lei Lin,Lei Ze-yong,Lei Jie-heng,Zhao Mu,Hua Yun-fei 한국원자력학회 2023 Nuclear Engineering and Technology Vol.55 No.11

        A new method of numerical simulating prediction and decontamination effect evaluation for abrasive jet decontamination to radioactively contaminated metal is proposed. Based on the Computational Fluid Dynamics and Discrete Element Model (CFD-DEM) coupled simulation model, the motion patterns and distribution of abrasives can be predicted, and the decontamination effect can be evaluated by image processing and recognition technology. The impact of three key parameters (impact distance, inlet pressure, abrasive mass flow rate) on the decontamination effect is revealed. Moreover, here are experiments of reliability verification to decontamination effect and numerical simulation methods that has been conducted. The results show that: 60Co and other homogeneous solid solution radioactive pollutants can be removed by abrasive jet, and the average removal rate of Co exceeds 80%. It is reliable for the proposed numerical simulation and evaluation method because of the well goodness of fit between predicted value and actual values: The predicted values and actual values of the abrasive distribution diameter are Ф57 and Ф55; the total coverage rate is 26.42% and 23.50%; the average impact velocity is 81.73 m/s and 78.00 m/s. Further analysis shows that the impact distance has a significant impact on the distribution of abrasive particles on the target surface, the coverage rate of the core area increases at first, and then decreases with the increase of the impact distance of the nozzle, which reach a maximum of 14.44% at 300 mm. It is recommended to set the impact distance around 300 mm, because at this time the core area coverage of the abrasive is the largest and the impact velocity is stable at the highest speed of 81.94 m/s. The impact of the nozzle inlet pressure on the decontamination effect mainly affects the impact kinetic energy of the abrasive and has little impact on the distribution. The greater the inlet pressure, the greater the impact kinetic energy, and the stronger the decontamination ability of the abrasive. But in return, the energy consumption is higher, too. For the decontamination of radioactively contaminated metals, it is recommended to set the inlet pressure of the nozzle at around 0.6 MPa. Because most of the Co elements can be removed under this pressure. Increasing the mass and flow of abrasives appropriately can enhance the decontamination effectiveness. The total mass of abrasives per unit decontamination area is suggested to be 50 g because the core area coverage rate of the abrasive is relatively large under this condition; and the nozzle wear extent is acceptable

      • KCI등재

        Influence of stator vane number on performance of the axial-flow pump

        Can Kang,Xiaojie Yu,Weifeng Gong,Changjiang Li,Qifeng Huang 대한기계학회 2015 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.29 No.5

        The interplay of impeller and stator is investigated for an axial-flow pump. Three stator vane numbers of 5, 7 and 9 are devised tomatch the same impeller. The renormalization group k-ε turbulence model is used to simulate three-dimensional flows in three pumpswith different vane numbers. Axial velocity distributions at impeller outlet and stator outlet are comparatively analyzed. Experimentsassess operation performance of the three pumps. Vibration parameters and static pressure fluctuations are measured as well. It is indicatedthat the influence of vane number on both pump head and pump efficiency is insignificant. Large stator vane number contributes tothe improvement of the uniformity of axial velocity distribution at impeller outlet. At stator outlet, similar tendency is revealed. Severevibration occurs near the outlet bend of the pump, as is particularly remarkable at vane number of 9. For the three cases, blade passingfrequency and its harmonics are predominant in the frequency spectra of pressure fluctuations. As flow rate increases from 0.8Q to 1.0Q,high-frequency pressure fluctuations are suppressed considerably at vane number of 9, while the other two cases also manifest a declinein overall pressure fluctuation amplitude. The 7-vane case is the most preferable one among the three cases in terms of both pump performanceand pressure fluctuation between the impeller and the stator.

      • KCI등재

        Quasi-Fixed-Frequency Hysteresis Current Tracking Control Strategy for Modular Multilevel Converters

        Jun Mei,Yu Ji,Xiaozhou Du,Tian Ma,Can Huang,Qinran Hu 전력전자학회 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.6

        This study proposes a quasi-fixed-frequency hysteresis current tracking control strategy for modular multilevel converters (MMCs) on the basis of voltage partition principle. First, by monitoring the grid voltage and the deviation between the output and reference currents, the output voltage is determined, thus prompting the output current to quickly and efficiently track the given current. Second, the voltages of the upper/lower capacitor of the arm and the voltages between the upper and lower arms are balanced by combining these arms with virtual loop mapping and arm voltage balance control, respectively. In particular, the proposed method is designed for any level and number of sub-modules. The validity of the proposed method is verified by simulations and experimental results of a five-level MMC prototype.

      • SCIESCOPUSKCI등재

        Quasi-Fixed-Frequency Hysteresis Current Tracking Control Strategy for Modular Multilevel Converters

        Mei, Jun,Ji, Yu,Du, Xiaozhou,Ma, Tian,Huang, Can,Hu, Qinran The Korean Institute of Power Electronics 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.6

        This study proposes a quasi-fixed-frequency hysteresis current tracking control strategy for modular multilevel converters (MMCs) on the basis of voltage partition principle. First, by monitoring the grid voltage and the deviation between the output and reference currents, the output voltage is determined, thus prompting the output current to quickly and efficiently track the given current. Second, the voltages of the upper/lower capacitor of the arm and the voltages between the upper and lower arms are balanced by combining these arms with virtual loop mapping and arm voltage balance control, respectively. In particular, the proposed method is designed for any level and number of sub-modules. The validity of the proposed method is verified by simulations and experimental results of a five-level MMC prototype.

      • KCI등재

        Causal Relations between Exposome and Stroke: A Mendelian Randomization Study

        Hong-Qi Li,Yi-Wei Feng,Yu-Xiang Yang,Xin-Yi Leng,Prof Can Zhang,Shi-Dong Chen,Kevin Kuo,Shu-Yi Huang,Xue-Qing Zhang,Yi Dong,Xiang Han,Xin Cheng,Mei Cui,Lan Tan,Qiang Dong,Jin-Tai Yu 대한뇌졸중학회 2022 Journal of stroke Vol.24 No.2

        Background and Purpose To explore the causal relationships of elements of the exposome with ischemic stroke and its subtypes at the omics level and to provide evidence for stroke prevention. Methods We conducted a Mendelian randomization study between exposure and any ischemic stroke (AIS) and its subtypes (large-artery atherosclerotic disease [LAD], cardioembolic stroke [CE], and small vessel disease [SVD]). The exposure dataset was the UK Biobank involving 361,194 subjects, and the outcome dataset was the MEGASTROKE consortium including 52,000 participants. Results We found that higher blood pressure (BP) (systolic BP: odds ratio [OR], 1.02; 95% confidence interval [CI], 1.01 to 1.04; diastolic BP: OR, 1.03; 95% CI, 1.01 to 1.05; pulse pressure: OR, 1.03; 95% CI, 1.00 to 1.06), atrial fibrillation (OR, 1.18; 95% CI, 1.13 to 1.25), and diabetes (OR, 1.13; 95% CI, 1.07 to 1.18) were significantly associated with ischemic stroke. Importantly, higher education (OR, 0.69; 95% CI, 0.60 to 0.79) decreased the risk of ischemic stroke. Higher systolic BP (OR, 1.06; 95% CI, 1.02 to 1.10), pulse pressure (OR, 1.08; 95% CI, 1.02 to 1.14), diabetes (OR, 1.28; 95% CI, 1.13 to 1.45), and coronary artery disease (OR, 1.58; 95% CI, 1.25 to 2.00) could cause LAD. Atrial fibrillation could cause CE (OR, 1.90; 95% CI, 1.71 to 2.11). For SVD, higher systolic BP (OR, 1.04; 95% CI, 1.00 to 1.07), diastolic BP (OR, 1.06; 95% CI, 1.01 to 1.12), and diabetes (OR, 1.22; 95% CI, 1.10 to 1.36) were causal factors. Conclusions The study revealed elements of the exposome causally linked to ischemic stroke and its subtypes, including conventional causal risk factors and novel protective factors such as higher education.

      • SCIESCOPUSKCI등재
      • Relation between Ki-67, ER, PR, Her2/neu, p21, EGFR, and TOP II-α Expression in Invasive Ductal Breast Cancer Patients and Correlations with Prognosis

        Yan, Jian,Liu, Xiao-Long,Han, Lu-Zhe,Xiao, Gang,Li, Ning-Lei,Deng, Yi-Nan,Yin, Liang-Chun,Ling, Li-Juan,Yu, Xiao-Yuan,Tan, Can-Liang,Huang, Xiao-Ping,Liu, Li-Xin Asian Pacific Journal of Cancer Prevention 2015 Asian Pacific journal of cancer prevention Vol.16 No.2

        The aim of the present study was to investigate the expression of the transcription factor Ki-67, ER, PR, Her2/neu, p21, EGFR, and TOP II-${\alpha}$ in the tumor tissue of patients with invasive ductal carcinoma(IDC); in addition, we examined correlations between these markers. Two hundred and sixteen IDC patients, who were not previously been treated with chemo- or radiotherapy, were included in the study. All tumors were grade I-III. Expression of molecular markers was determined by immunohistochemical analysis on paraffin-embedded tissue sections. Follow-up data were collected for 3 months to 10 years and analyzed for tumor recurrence, survival time, and prognostic risk factors. We determined Ki-67 expression correlates with the expression of ER, PR, HER-2, EGFR, and TOP-${\alpha}$, as well as lymph node involvement, high tumor grade, lymphovascular invasion, high tumor stage, and high TNM stage in IDC. Positive Ki-67 expression was a risk factor for rapid tumor recurrence and may help tumor progression, leading to poor prognosis in IDC. Ki-67 was directly correlated with EGFR, TOP II-${\alpha}$, lymph node involvement, high tumor grade, lymphovascular invasion, high tumor stage, and high TNM stage in the hormone receptor subtypes of breast cancer. In triple negative breast cancer, Ki-67 correlated with TOP II-${\alpha}$. Expression of Ki-67 correlated with that of ER, PR, HER-2, EGFR, TOP II-${\alpha}$, and p21. In addition, the biomarker Ki-67 has a role as a prognostic factor and indicates a poor prognosis in IDC.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼