중부지역 공동주택의 창면적비에 따른 건물에너지효율등급 평가
장철용(Jang Cheol-Yong),한혜심(Han Hye-Sim),이진숙(Lee Jin-Sook) 한국건축친환경설비학회 2010 한국건축친환경설비학회 학술발표대회 논문집 Vol.2010 No.3
Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate in a apartment with Building Energy Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.
장철용(Jang Cheol-Yong),조수(Cho Soo),박상우(Park Sang-Woo) 한국태양에너지학회 2009 한국태양에너지학회 학술대회논문집 Vol.- No.-
Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. To reduce the loss of the energy which leads, to an air conditioning energy and an expense increase problem the color which the interior furniture and the clothing due to the augmentation and the corpse ultraviolet rays of the unpleasant feeling which is caused by with the transient one solar energy influx which leads the window will burn, it joins in the window and it confronts and the novel solution is demanded.
시뮬레이션 이용한 열교차단제 적용에 따른 단열문 열성능 분석
장철용(Jang Cheol-Yong),김치훈(Kim Chi-Hoo),안병립(Ahn Byung-Lip),홍원화(Hong Won-Hwa) 한국태양에너지학회 2010 한국태양에너지학회 학술대회논문집 Vol.2010 No.4
Currently, Exterior wall's U-value about building envelope is 0.29~0.47W/㎡K(Central Region), but window's one is 3.3W/㎡K according to air gap of glazing, filling gas, coating and type of windows. The door's one is 1.6~5.5W/㎡ · K depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one.
난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가
장철용(Jang Cheol-Yong),김정국(Kim Jeong-Gook),안병립(Ahn Byung-Lip),김준섭(Kim Jun-Sup),한찬훈(Haan Chan-Hoon) 한국태양에너지학회 2012 한국태양에너지학회 학술대회논문집 Vol.2012 No.3
In the high oil price age, intensification of energy efficiency promotion in the building sector is required, Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency, In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.
열화상 측정장비를 활용한 스틸스터드 형상에 따른 열성능 비교분석
장철용(Cheol-Yong Jang),엄은정(Eun-Jung Um),이나은(Na-Eun Lee) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
Dry wall using steel stud has the advantage of possibility to install various building, so it used to many buildings inside and outside of the country very rapidly. Though Light gauge steel framed housing offers many advantages to the consumer and the builder, the use of steel studs in wall system cause thermal problems such as thermal performance and pattern staing on walls. The present study has been conducted to observe effect of stud by the shape, and two kind of stud is made for this test to compare thermal performance. The test was conducted by setting those stud on the chamber and heating them. As the results of test and photograping by using TVS, there was temperature gap of each stud, and surface temperature of each section was appeared differently due to shape of stud delaying thermal bridge.
Tilt & Sliding 시스템창호의 단열성능 실측과 시뮬레이션 비교 분석
장철용(Jang Cheol-Yong),안병립(Ahn Byung-Lip),김치훈(Kim Chi-Hoon),홍원화(Hong Won-Hwa) 한국태양에너지학회 2009 한국태양에너지학회 학술대회논문집 Vol.2009 No.11월
The parts of building which has the most influence on thermal load are skins, outer walls and windows. Among them, window is the worst weak point of building even if it has many advantage of solar radiation gain than other parts. The present time, many researches on various performance of window and many types of system-window are being made. This study evaluates thermal performance of tilt & sliding system window by simulation program Therm 5.2 and Window 5.2. After making a sample model improving it's thermal weak point, this study evaluates real thermal performace of system window. As a result, this study understands manufacture ability condition of domestic company and proposes a research plan of system window.
더블로이유리 적용 창호의 구성요소에 따른 단열성능 비교 실험
장철용(Jang Cheol-Yong),안병립(Ahn Byung-Lip),김치훈(Kim Chi-Hoon),김준섭(Kim Jun-Sub),이성재(Lee Sung-Jae) 한국태양에너지학회 2011 한국태양에너지학회 학술대회논문집 Vol.2011 No.4
Low-e glazing is classified as soft low-e glazing and hard low-e glazing. Hard low-e glazing can be temperable and its handling is comfortable because its coating film is a oxide film generated at high temperatures. But there is a fatal weakness that its insulation performance and shielding performance are lower compared to soft low-e glazing by low electrical conductivity of coating film. Soft low-e glazing is excellent because its coating film consists of Ag that is excellent electrical conductivity and it has strength that can supply various product consumers want. But soft low-e glazing has weaknesses that temperable and handling are difficult because Ag is oxidized easily. Therefore this study analyzes thermal performance of glazing by changing filling gas according to applying low-e glazing through simulation to judge performance before making sample. After this process, a comparative experimental study was done through TVS by making temperable low-e glazing.
전문가 설문조사를 통한 건축물 에너지효율등급 인증제도에 관한 연구
장철용(Jang Cheol-Yong),이나은(Lee Na-Eun) 대한건축학회 2011 대한건축학회논문집 Vol.27 No.5
The measures for energy saving in buildings have been tried because particularly the role of building division is very important for implementing national greenhouse gas reduction targets and Green growth. However there are many problems due to lack of relevant personnel to do this work. Furthermore it is expected that certification services will be increased by revitalizing the Building Energy Rating System and expanding the target of certification. Therefore Government must prepare for the expansion of the Building Energy Rating System by training experts with effort to supply low-energy building. This expert survey results are that 72% of the respondents answer that expansion of the certification authority is needed to prepare for increase in the certification and 87% answer that training experts is needed. In this study, we suggest the basic data for the introduction of obligation and expanding certification by analyzing the operating system and legal system of the Building Energy Rating System. Additionally, the operating and legal system of the Building Energy Rating System which is appropriate for our country will need to be built based on practices in developed countries to present way to expand the target of certification.