공동주택 창호 선정에 따른 에너지 절감 효과 및 경제성 평가
윤성환(Yoon Seong-Hwan),송수빈(Song Su-Bin),김영탁(Kim Young-Tag),염성곤(Yum Seong-Kon) 대한건축학회 2008 대한건축학회논문집 Vol.24 No.8
This study investigated the 7 performance of domestic windows for an apartment house, examined the energy saving effects according to the window thermal performance and estimated the window economical efficiency. As a result of this study, in case of 85 ㎡ standard housing model, annual heat load was decreasing by 10% according to increasing in window shading coefficient to 0.2, fixing window U-value 2.30 W/㎡K and annual heat load was increasing by 38% according to increasing in window U-value to 1.00 W/㎡K, fixing window shading coefficient 0.7. When the window with U-value 2.30W/㎡K was applied to the standard housing model, window expense increased by 43% but cooling and heating energy expense decreased by 16% annually compare with the case using the window with 3.11W/㎡K, consequently it took 14 years to retrieve the additional window expenses with energy saving expense.
동적열부하계산을 통한 공동주택 창호 단열사양에 따른 냉난방부하 절감효과 분석
윤성환(Yoon Seong-hwan),송수빈(Song Su-bin),김영탁(Kim Young-tag),염성곤(Yum Seong-kon) 한국건축친환경설비학회 2008 한국건축친환경설비학회 논문집 Vol.2 No.3
This study is conducted to find out how the heating and cooling loads change by thermal performance by the dynamic heat load simulation program. The study results are as followings. (1) It is revealed that SC is changeable if a window is Low-E coated and by the colors of windows. U-value of window is highly related to the thickness and the kind of window rather than the colors of window. (2) The thermal insulation property of double window whose U-value is distributed 1-2W/㎡K is twice of the thermal insulation property of single window. The mean U-value of PVC window is about 1.0W/㎡K beneficial compared to the mean U-value of aluminum window, which is concluded that it is highly advantageous to take in consideration of the thermal insulation property. (3) As SC increases by 0.1, it shows that annual heating and cooling loads decrease by approximately 5%. And as U-value of window increases by 0.5W/㎡K, annual cooling and heating loads increase by approximately 15%. (4) The simulation results show that annual cooling and heating load is different by 134% to the utmost, as it is appeared to be minimums of 213 MJ/㎡ㆍyr in case of U-value0.6-SC0.6 and maximum of 499MJ/㎡ㆍyr in case of U-value3.0-SC0.4.
명료도 지수를 이용한 사무실의 대화프라이버시 개선 방안
김윤정(Kim Youn-Jung),염성곤(Yum Sung-Kon),이성현(Lee Seong-Hyun),송두삼(Song Doo-Sam),김예상(Kim Yea-Sang) 대한건축학회 2010 대한건축학회논문집 Vol.26 No.8
Modern enterprises often place more employees in a smaller area in order to reduce costs. Also, due to the development of office equipment, there are a lot of items which increase noise, such as telephones, video conference facilities, computers, etc. As environmental conditions of offices have become the most fundamental and important issues to improve work efficiency and productivity, this study aims to find out the present state of speech privacy in open plan offices taking an actual measurement and determines how to improve speech privacy using the acoustic simulation software EASE. The target office is realized in the simulation, and four factors are changed: ceiling material, height of partitions, floor material and masking noise. Therefore, it finds out that the most effective way among architectural influential factors is using a high-absorption ceiling material. Also, the method of using a masking noise is one of the effective ways, but it makes employees so annoyed that it is important to consider it only if it does not make them uncomfortable.
동적열부하시뮬레이션에 의한 공동주택 창호의 단열성능 검토
송수빈(Song Su-bin),김영탁(Kim Young-tag),염성곤(Yum Seong-kon),윤성환(Yoon Seong-hwan) 한국건축친환경설비학회 2008 한국건축친환경설비학회 학술발표대회 논문집 Vol.- No.-
This study is conducted to find out how the heating and cooling loads change by thermal performance by the dynamic heat load simulation program. The study results are as followings. (1) As SC decreases by 0.1, it shows that annual heating and cooling loads decrease by approximately 5%. And as U-value of window increases by 0.5W/㎡K, annual cooling and heating loads increase by approximately 15%. (2) The simulation results show that annual cooling and heating load is different by 134% to the utmost, as it is appeared to be minimums of 213 MJ/㎡ㆍyr in case of U-value0.6-SC0.6 and maximum of 499MJ/㎡ㆍyr in case of U-value3.0-SC0.4.
공동주택 창호의 단열효과와 시공비용 분석을 통한 경제성 평가
송수빈(Song Su-Bin),김영탁(Kim Young-Tag),염성곤(Yum Seong-Kon),윤성환(Yoon Seong-Hwan) 대한건축학회 2008 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.28 No.1(계획계)
This study investigated the thermal performance of domestic windows for an apartment house, examined the energy saving effects according to the window thermal performance and estimated the window economical efficiency. As a result of this study, in case of 85 ㎡ standard housing model, annual heat load was decreasing by 10% according to increasing in window shading coefficient to 0.2, fixing window U-value 2.30 W/㎡K and annual heat load was increasing by 38% according to increasing in window U-value to 1.00 W/㎡K, fixing window shading coefficient 0.7. When the window with V-value 2.30W/㎡K was applied to the standard housing model, window expense increased by 43% but cooling and heating energy expense decreased by 16% annually compare with the case using the window with 3.11W/㎡K, consequently it took 14 years to retrieve the additional window expenses with energy saving expense.
송수빈(Song Su-Bin),김영탁(Kim Young-Tag),염성곤(Yum Seong-Kon),윤성환(Yoon Seong-Hwan) 한국태양에너지학회 2008 한국태양에너지학회 학술대회논문집 Vol.- No.-
This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in Korean and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.