유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가
김동연,양천승,이광영,김지환 대한치과기공학회 2020 대한치과기공학회지 Vol.42 No.1
Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type Ⅳ stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 μm and that of fiberglass resin was 224.92 μm. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.
치과 3D 프린팅용 자외선 경화 레진에 광원의 두 가지 파장에 따른 경화 및 항온수조 침적에 따른 변형률의 비교 분석
김동연,이광영,강후원,양천승,Kim, Dong-Yeon,Lee, Gwang-Young,Kang, Hoo-Won,Yang, Cheon-Seung 대한치과기공학회 2020 대한치과기공학회지 Vol.42 No.3
Purpose: This study aimed to analyze the shrinkage and expansion strain of ultraviolet (UV)-cured resin according to the wavelength of the light source and compare the shrinkage and expansion. Methods: We prepared the mold with according to the ISO 4049 specimen. The size of the circle in the mold was prepared with a height of 6.02 mm and a diameter of 4 mm. UV-curable resin for three-dimensional (3D) printing was injected into the circular mold. The control group was irradiated with a wavelength of 400~405 nm using UV-curing equipment (400 group), and the experimental group was irradiated with a wavelength of 460~465 nm (460 group). Both groups were produced ten specimens. The produced specimen was first measured with a digital micrometer. After the first measurement, the specimen was immersed in a constant temperature water bath for 15 days, after which the second measurement was performed, and the third measurement was taken after 30 days. The measured values were analyzed using the independent sample t-test (α=0.05). Results: In the non-immersion water tank, the contraction was 0.9% in the 400 group and 1.3% in the 460 group. In the constant temperature bath, the expansion was high at -0.4% in the 400 group for 15 days, and the smallest expansion was -0.03% for the 400 group for 30 days. There were significant differences between the two groups (p<0.05). Conclusion: The 400 group had a lower UV resin specimen strain than the 460 group. Therefore, it is recommended to use the wavelength required by the UV-curing resin.
3D 프린팅용 광경화 수지를 사용하여 제작한 의치상용 인공치아의 항온수조 침적에 따른 변형률 비교 분석
김동연,이광영,김재홍,양천승,Kim, Dong-Yeon,Lee, Gwang-Young,Kim, Jae-Hong,Yang, Cheon-Seung 대한치과기공학회 2020 대한치과기공학회지 Vol.42 No.3
Purpose: This study is a comparative analysis of the strain according to deposition in a constant temperature water bath after manufacturing ultraviolet (UV)-cured artificial teeth. Methods: As a control group, 10 ready-made artificial teeth were selected as the first molar on the right side of the maxilla (RT group). Silicone was used as a duplicate of the artificial denture teeth. Experimental teeth were prepared in two groups using the prepared silicone mold. In the first experimental group, the UV-cured resin was injected into the negative silicone, followed by irradiation with a UV-curing machine for 5 minutes (5M group). In the second experimental group, the UV-cured resin was injected into the negative silicone, and then irradiated for 30 minutes using a UV-curing machine (30M group). The one-way ANOVA was performed, and post-test was analyzed by Tukey. Results: When immersed in a water bath for 15 days, it was found to be -0.3% in the RT group, -0.6% in the 5M group, and -0.7% in the 30M group. The results revealed -0.2% in the RT group, 0.2% in the 5M group, and -0.2% in the 30M group when they were in the bath for 30 days. Conclusion: In the water bath, the swelling was greater when deposited for 1 to 15 days, but was less when deposited for 15 to 30 days.