원저(原著) : 혈액원에서의 성분제제용 전혈 보관 및 운송용 냉매제에 관한 고찰
양대형 ( Dae Hyung Yang ),최범열 ( Bum Ryoul Choi ),김미경 ( Mi Kyung Kim ),장주환 ( Ju Whan Jang ),홍영진 ( Young Jin Hong ),이동범 ( Dong Beom Lee ) 대한임상병리사협회 1999 임상수혈검사학회 발표자료집 Vol.5 No.1
The effect of rapid cooling to 20~24℃ of whole blood immediately after collection, using'cooling unit' minimized damage of platelet function and yield high anticoagulant factor in the plasma. Though, Ice pack, a sort of cooling units, was proved inadquate to preserve platelet concentration because of hard cooling force. In comparison between cooling faculty experiment of foreign and national cooling unit, it has been shown similar to the dissolved and frozen changing point. In case of preservation whole blood 4 units per cooling 1 unit, it has been shown cooling down below 24℃ in 1 hour 40 minute and can be maintained 20℃ above 8 hours after blood collection. From the above literature, national cooling unit, substituted foreign cooling unit, has not special problem. Therefore, the author conclusioned hat using cooling unit contribute to quality improvement of blood and standardization of the subsequently prepared blood components and will diminish processing at irregular hour or season cause.
5일 보존용 채혈백에 따른 보존일자별 농축혈소판의 생화학 및 성상 분석
이동범,유태종,김태전,김승곤,신종관,양대형,고광임,박성훈 임상병리검사과학회 2002 임상병리검사과학회지 Vol.34 No.2
Biochemical changes and icon of platelets on platelet concentrates preserved for a 5day term in several plastic containers were investigated. The authors evaluated the TOTM-PVC second generation container produced by Green Cross Medical Corp. and Boin medica. Blood obtained from 40 persons was manufactured for platelet concentrates within 4 hours and each divided into 20 units of platelet concentrations. Samples were taken at 0, 3, and 5days and the platelet count, pH, pO_(2), pCO_(2), HCO_(3)-, glucose, LDH, lactate, electrolytes, and mineral element were tested The number and MPV, for platelets icon, were well preserved on two different platelet concentrates during storage. A test for biochemical function appeared to be effective data. pH was maintained above 6.8 on two different platelet concentrates during storage. The results suggest that the TOTM-PVC second generation platelets storage container produced by Green Cross Medical Corp. and Boin medica was able to preserve platelets for at least five days without lesion and was it concluded to have biochemical efficacy on patients with transfusions.
원저 : RDP와 세가지 유형의 Plateletpheresis를 비교 분석한 혈소판 성분의 특성 및 LDH Titer
이동범 ( Dong Beom Lee ),유태종 ( Tae Joung Yoo ),최범열 ( Bum Ryoul Choi ),김태전 ( Tai Jeon Kim ),양대형 ( Dae Hyung Yang ),임영근 ( Young Keun Lim ) 대한임상병리사협회 2003 임상수혈검사학회 발표자료집 Vol.8 No.1
Characteristic and Lactate dehydrogenase titer of platelet components obtained with three type of cell separators compared with random donor platelet concentrates were investigated. Collective efficiency of platelets obtained with the Amicus™ and Trima were higher than with the MCS+. The effect of biochemical changes on pH, Blood Gas permeability, Glucose and LDH in platelet concentrates obtained with the Amicus™ and Trima were more preserved than in concentrates from the MCS+, but LDH titer of SDP were not effectively seen compared with RDP. Therefore, we indicated that different plateletphresis procedure induced distinct changes of platelet function Platelets obtained with the MCS cell separator were significantly more activated than platelets harvested with the Amicus™ and Trima.
5일 보존용 채혈백에 따른 보존일자별 농축혈소판의 생화학 및 성상 분석
이동범 ( Dong Beom Lee ),유태종 ( Tae Joung Yoo ),김태전 ( Tai Jeon Kim ),김승곤 ( Seung Kon Kim ),신종관 ( Jong Kwan Shin ),양대형 ( Dae Hyung Yang ),고광임 ( Goung Yim Ko ),박성훈 ( Seung Hun Park ) 대한임상검사과학회 2002 대한임상검사과학회지(KJCLS) Vol.34 No.2
Biochemical changes and icon of platelets on platelet concentrates preserved for a 5 day term in several plastic containers were investigated. The authors evaluated the TOTM-PVC second generation container produced by Green Cross Medical Corp. and Boin medica. Blood obtained from 40 persons was manufactured for platelet concentrates within 4 hours and each divided into 20 units of platelet concentrations. Samples were taken at 0, 3, and 5 days and the platelet count, pH, p02, pC02, HC03-, glucose, LDH, lactate, electrolytes, and mineral element were tested. ’fhe number and MPV, for platelets icon, were well preserved on two different platelet concentrates during storage. A test for biochemical function appeared to be effective data. pH was maintained above 6.8 on two different platelet concentrates during storage. The results suggest that the TOTM-PVC second generation platelets storage container produced by Green Cross Medical Corp. and Boin medica was able to preserve platelets for at least five days without lesion and was it concluded to have biochemical efficacy on patients with transfusions.