지열을 이용한 공조외기부하 저감 시스템의 열성능 예측을 위한 수치모델
손원득(Won-Tug Son),안창환(Chang-Hwan Ahn),공성훈(Sung-Hoon Kong) 한국생활환경학회 2007 한국생활환경학회지 Vol.14 No.2
This paper presents a feasibility study of a fresh air load reduction by using an underground double floor space. The system was introduced into a real building and was examined by the field measurement. Judging from the measurements during three years (1999~2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation was developed to simulate its thermal characteristics and performances. The simulations resulted in air temperature in good agreement with the measurements. Also, from the result of numerical analysis, it is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.
손원득(Won-Tug Son),장환(Hwan Jang),신지웅(Jee-Woong Shin),김종민(Jong-Min Kim),박찬석(Chan-Seok Park),조종선(Jong-Sun Cho) 대한설비공학회 2012 대한설비공학회 학술발표대회논문집 Vol.2012 No.6
This study has been conducted to propose an optimal design guidance of underfloor air distribution system by examining air pattern and proper exhaust status of floor plenum using CFD (Computational Fluid Dynamics). Simulation shows deficient air pattern and exhaust status at BPG (Bypass Grille) of the current design. As a means to find an alternative design, four cases have been developed and tested. Case 1,2 and 3 show similar results in comparison to the current design. However, case 4 shows improved air pattern and exhaust status at BPG(Bypass Grille), and has been chosen as the optimal alternative.
신재생에너지 사용이 도시열섬방지에 미치는 영향에 대한 연구
손원득(Won-Tug Son),최영식(Young-Sik Choi) 한국산업융합학회 2009 한국산업융합학회 논문집 Vol.12 No.3
Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we use numerical model in order to analyze quantitative effects by using new & renewable energy on the heat island phenomenon in urban area. The present study quantitatively analyzes the Urban Heat Island Effects, Energy-Saving Effects, and Environmental Load Decrease Effect along New and Renewable Energy Application which is 10% of the Building Energy Consumption.
지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구
손원득(Won-Tug Son),박경순(Kyung-Soon Park) 대한설비공학회 2010 설비공학 논문집 Vol.22 No.9
This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.
지열을 이용한 空調外氣負荷低減시스템의 설계 및 도입 효과에 관한 연구-실측결과 및 열성능 예측을 위한 수치모델의 제안-
손원득(Won-Tug Son),최영식(Young-Sik Choi) 한국산업융합학회 2004 한국산업융합학회 논문집 Vol.7 No.3
This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space The system was introduced into a real building and was examined by the field measurement Judging from the measurements during three years(1999-2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation Was developed to simulate its thedtial charactenshes and performances The simulations resulted m air temperature 10 good agreement with the measurements. Also, from the result of numerical analysis, It is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.<br/>
공동주택을 대상으로 경제성을 고려한 에너지성능 최적화 기법에 관한 연구
손원득(Won-Tug Son),이종일(Jong-il Lee),박승길(Seung-kil Park),천정길(Jung-gil Chun),윤대원(Dae-wonYoon),송두삼(Seo, Doosam Song) 한국태양에너지학회 2013 한국태양에너지학회 학술대회논문집 Vol.2013 No.11
So many energy saving strategies to realize the low energy house are proposed in these days. Even if the energy saving performances are similar between the strategies, the costs are in a broad ranges. Therefore, the application of the energy saving strategies should be based upon two considerations; one is energy saving performance and the other is the cost. In this study, the decision making method for application of the passive design technologies in the design stage of the low energy apartment house are suggested. By utilizing the result of this study, practitioners can make an effective design alternatives which solve the conflicted values; energy saving and cost.
지열을 이용한 空調外氣負荷低減 시스템의 설계 및 도입 효과에 관한 연구 - 증기 확산지배에 의한 열수분 동시 이동 수치모델의 제안 -
손원득(Won-tug Son),최영식(Young-sik Choi) 한국산업융합학회 2004 한국산업융합학회 논문집 Vol.7 No.4
This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we used a model for evaluation of fresh air latent heat load reduction by hygroscopic of air to earth exchange system taking into account coupled heat and moisture transfer of underground double floor space. In conclusion it shows the validity of the proposed method for a design tool and the quantitative effect of the system.<br/> <br/>
건물과 녹지배치가 외부 열환경 변화에 미치는 영향 분석
손원득(Won-Tug Son),최현상(Hyun-Sang Choi),최영식(Young-Sik Choi) 한국산업융합학회 2010 한국산업융합학회 논문집 Vol.13 No.2
Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we use CFD simulation in order to analyze quantitative effects by placing a Building and Green on the heat island phenomenon in urban area. The present study quantitatively analyzes the Urban Heat Island Effects, Outdoor air temperature, and Humidity and air flow.