http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박근우,임성순,장석윤,Park, Keun Woo,Yhim, Sung Soon,Chang, Suk Yoon 한국강구조학회 2000 韓國鋼構造學會 論文集 Vol.12 No.2
In this paper, stability analysis is carried out for the out of plane behaviors under compressive loads to the direction of the generator in anisotropic cylindrical shells. It is not easy to obtain the analytic solutions about the stability analysis of anisotropic cylindrical shells consisted of composite materials. For solving this problems, this paper used the finite difference method which is one of the numerical methods. Geometrical property of cylindrical shells transforms the compressive loads into the inplane behaviors. This paper studied the change of stiffness in the direction of the circumferential and stability of shells according to change of fiber angle, curvature, subtended angle and aspect ratio. From result of this study, anisotropic cylindrical shells under compressive loads to the direction of the generator vary greatly with respect to the change of the circumferential stiffness. Therefore, it will be more safe to strengthen the circumferential stiffness of anisotropic cylindrical shells under compressive loads. 본 연구의 목적은 비등방성 원통형 쉘이 원통길이방향으로 압축하중을 받는 경우 면외방향 거동의 안정성에 대한 해석이다. 복합재료로 이루어진 비등방성 원통형 쉘의 안정성 해석은 해석적인 방법으로는 해를 얻을 수 없으므로 수치해석 기법중의 하나인 유한차분법을 사용하였다. 원통형 쉘은 기하학적 특성상 원통길이방향의 압축하중을 원주 방향의 면내거동으로 저항하는 구조형식이므로 원주방향 강성변화에 중점을 두고 연구를 수행하였다. 또한 비등방성 원통형 쉘이 원통길이방향으로 압축하중을 받는 경우에 발생하는 거동에 대한 예측이 힘들기 때문에 화이버 보강각도 변화, 곡률변화, 중심각 변화, 형상비 변화에 따른 안정성 문제를 연구하였다. 본 연구의 결과에 의하면 원통길이방향으로 압축하중을 받는 비등방성 원통형 쉘은 원주방향 강성에 의하여 안정성에 큰 변화가 있다는 것을 알 수 있었다. 그러므로 압축하중을 받는 비등방성 원통형 쉘은 원주방향에 대하여 보강하는 것이 쉘 구조의 안정성을 높일 수 있을 것으로 예측된다.
박근우(Park, Geun-Woo),이응열(Lee, Eung-Youl) 한국신재생에너지학회 2007 신재생에너지 Vol.3 No.2
Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in 12{sim}20?... annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is 800{sim}1000;ton/day. The heat pump capacity is 5RT. The heat pump heating COP was 3.85{sim}4.68 for the open type and 3.82{sim}4.69 for the close type system. The system heating COP including pump power is 3.0{sim}3.32 for the open type and 3.32{sim}3.84 for close type system. This performance is up to that of BHE type ground source heat pump.
유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능
박근우(Park, Geun-Woo),김진상(Kim, Jin-Sang),이응열(Lee, Eung-Youl) 한국신재생에너지학회 2006 신재생에너지 Vol.2 No.2
유출지하수나 지표수를 열원으로 지열히트펌프의 지초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 5,500{sim}4,500kcal/h의 열량이 전달되었고 수조를 Heat Sink로 사용할 경우 5,200{sim}3,500kcal/h의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교한 결과 실험에 의해 유추된 U값이 24{sim}27% 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.