http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김용암,유점호 한국연초학회 1981 한국연초학회지 Vol.3 No.2
Data for this study were obtained from Burley 21 (Nicotiana tabacum L.) grown under various densities on the field in 1978 and 1979 at the Jeonju Experiment Station, Korea Ginseng & Tobacco Research Institute. Interrelations between yield and its components were statistically studied by correlation, regression, and pathway analysis. Correlation of yield with plant population was significant and positive. Quadratic functions for yield vs. plant population and the length of the largest leaf were fitted to the data. Multiple recession equation between yield and its components (leaf number ($X_1$), a leaf area ($X_5$), weight per unit leaf area ($X_9$), plant population ($X_14$)), was significant at the 5% level. Measuring the relative importance of its components on yield, plant population was 49.5%, weight per unit leaf area 25.3%, a leaf 15.6%, and leaf number 9.8%.
전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구
이춘하,옥경재,김점호,권병덕,차하나,윤계원 한국화재소방학회 2004 한국화재소방학회논문지 Vol.18 No.4
The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode. 정전기 방전에 의하여 주위의 가연성 가스에 폭발을 일으킬 수 있는 가스관련시설, 석유화학공장, 화약 공장, 필름생산공장, 반도체 공장 등과 같은 가연성 가스를 주로 취급하는 장소에서는 정전기를 제거하기 위해 제전기를 사용하고 있다. 본 연구에서는 이들 장소에서 주로 사용되고 있는 전압인가식제전기(static eliminator)의 Bar에서 발생하는 방전에 의한 가연성 가스의 폭발현상을 고찰하였다. 가연성 가스는 수소, 에틸렌, 프로판, 메탄 가스 등을 사용하였으며, 제전기의 이온발생 Bar의 길이, 이온발생 전극의 수 및 이 온발생 전극에 인가되는 전압의 변화에 따른 점화 현상을 연구하였다. 연구결과 Bar의 길이가 짧을수록 폭발의 위험성이 증가됨을 확인할 수 있었으며 또한 900 mm 이상의 Bar에서 전극의 수가 1개인 경우 일반적으로 사용하는 가연성 가스에서는 점화가 되지 않음을 알 수 있었다.