수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향
김인석,손병진,신현동,곽기태,Kim, I.S.,Son, B.J.,Shin, H.D.,Kwack, K.T. 대한설비공학회 1989 설비공학 논문집 Vol.1 No.2
This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.
김남수,김종보,김인석,최형진,Kim, N.S.,Kim, C.B.,Kim, I.S.,Choi, H.J. 대한설비공학회 1993 설비공학 논문집 Vol.5 No.3
Experimental investigations have been carried out to find the effect of drag reduction caused by effective polymer additives in turbulent flows. The experiments were undertaken with a test section of 9.8mm pipe diameter and 3500 mm pipe length(L/D=357) in a closed loop, and Copolymer-X and Polyacrylamide(PAAM) were used as polymer additives for comparisons. The tests were carried out under different polymer concentrations, and the temperatures of the flow considered were $26^{\circ}C$, $60^{\circ}C$ at the flow velocity of 5.3 m/s. The rate of drag reduction obtained by Copolymer-X is found to be considerably higher than that of PAAM in turbulent flows. Copolymer-X is also found to be very reliable for mechanical degradation, which has not been the case in any other additives. It is concluded that Copolymer-X is considered to be one of the most effective agents as an additive especially for long time hydraulic transports. It is also found that polymer degradation in more likely at lower polymer concentrations in the turbulent flows.
손병진,김인석,김문철,Son B.J.,Kim I.S.,Kim M.C. 대한설비공학회 1987 설비저널 Vol.16 No.5
This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.
수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향
손병진,김인석,김문철,Son B. J.,Kim I. S.,Kim M. C. 대한설비공학회 1987 설비저널 Vol.16 No.4
An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.
조광현,김인석,진영수,김재근 明知大學校 産業技術硏究所 1991 産業技術硏究所論文集 Vol.10 No.-
Two-phase flow phenomena are observed in many industrial facilities such as nuclear power plant and various heat exchangers. The experimental study has been investigated the classification of the flow pattern, the local void distribution and convective heat transfer in non-swirl two-phase flow under the isothermal and nonisothermal conditions.