220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석
고원식(Won-Sik Ko),문원식(Won-Sik Moon),방선배(Sun-Bae Bang),김재철(Jae-Chul Kim) 대한전기학회 2013 전기학회논문지 Vol.62 No.8
Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.
GIC 적용 대역통과필터를 이용한 컴퓨터 부하의 직렬 아크고장 전류 우수고조파 분석
고원식(Won-Sik Ko),문원식(Won-Sik Moon),방선배(Sun-Bae Bang),김재철(Jae-chul Kim) 대한전기학회 2012 전기학회논문지 Vol.61 No.10
In this paper, the even harmonic current(2nd, 4th, 6th, 8th) of the arc fault current and normal current were measured in computer load and analyzed. The BPF with GIC was developed to detection of harmonic, the exact center frequency and a high degree of sharpness could be easily obtained. The total even harmonic distortion due to series arc fault in computer load was 31.2%, this value was increased 3.9 times better than the total even harmonic distortion of normal current. The results of analysis of arc fault current RMS variation rate and Peak variation rate per half-cycle, The RMS average variation rate are as follows ; the 2nd harmonic was 0.24, the 4th harmonic was 0.15, the 6th harmonic was 0.19, the 8th harmonic was 0.25, respectively. The Peak average variation rate are as follows ; the 2nd harmonic was 0.19, the 4th harmonic was 0.12, the 6th harmonic was 0.13, the 8th harmonic was 0.15, respectively. The results of this analysis utilize data to detect of series arc fault on wiring of computer load.
고원식(Ko Won-Sig),이흥재(Lee Heung-Jae) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.4
In this paper, a real time monitoring and management system being operated in the ubiquitous environment was developed to monitor leakage current, load current, and arc-fault, and an electrical safety network for reasonable management of electrical risk factor was proposed. For confirmation of usefulness and reliability of the proposed safety network and system, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the network including the panels was operated. If the National Electrical Safety Network is completely constructed in the houses of general electrical users, the network will have an effect on that a main manager transfers from general people to expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.