대기오염과 천식증상에 의한 응급실내원과의 연관성에 관한 환자교차연구
임형준,이상윤,윤기정,주영수,강대희,조수현 대한산업의학회 2000 대한직업환경의학회지 Vol.12 No.2
Objectives : This study, using case-crossover design, search a relationship between changing levels of air pollutants and asthma attack in asthma patients. Methods : We searched the daily total number of asthmatic patients at hospital's emergency room in Seoul, Korea by investigating total 49 general hospital's emergency room records. Otherwise, We investigated medical records of asthmatic patients at one of the 49 hospitals we have searched. We investigated addresses that they are living, diagnosis, smoking history, whether respiratory infection or not, medications. We analyzed the data by 1:m conditional logistic regression used when matched case-control study is analyzed. Control periods were chosen by bidirectional paired matching technique 7, 14 days before and after case periods. Results : the relative risk of asthmatic attack by 100 ppm ozone increase between June and September were 1.348(95 % CI = 1.010∼1.619). Between November and February, the relative risk by 100 ㎍/㎥ TSP increase, 100ppb sulfur dioxide and nitrogen dioxide were respectively 1,278(1.010∼1.619), 1.237(1.019∼1.502), 1.285(1.006∼1.640). In stratified analysis, the relative risk were significant when the asthmatic patients were children aged 15 years or below, when there were respiratory infection, and when the patients took medications irregularly Conclusions : There was statistically significant association between ambient levels of air pollutants and asthmatic attack. So, we have to exert our efforts to minimize the air pollution effectively, to protect public health from air pollution.
Kim, Dong Jung,Cho, Young-Jae,Park, Sang Hon,Lim, Cheong,Park, Kay-Hyun,Jheon, Sanghoon,Kim, Jun Sung Ovid Technologies (Wolters Kluwer) - Lippincott Wi 2017 ASAIO journal Vol.63 No.5
<P>This study aimed to investigate the effectiveness of near-infrared spectroscopy (NIRS) monitoring for the early detection of limb ischemia in patients who were placed on veno-arterial extracorporeal membrane oxygenation (VA-ECMO) via femoral artery. We prospectively used NIRS monitoring for the early detection of limb ischemia in 28 adult patients, who were supported with peripheral VA-ECMO between August 2013 and August 2014 (NIRS group). A decision to perform distal perfusion catheterization was made in accordance with the regional oxygen saturation (rSO(2)) values provided by the NIRS system. For the comparison of outcome, the medical records of 36 adult patients who had been previously supported with peripheral VA-ECMO without NIRS monitoring (Control group), between July 2012 and July 2013, were retrospectively reviewed. There was no significant difference between the frequency of distal perfusion in both groups (p = 0.435). The mean time to distal perfusion is shorter in the NIRS group (19.6 +/- 21.4 vs. 42.0 +/- 69.0 hours). No patient underwent fasciotomy in the NIRS group, while 13.9% did in the control group (p = 0.040). We think that NIRS monitoring is a useful and reliable method for the early detection of limb ischemia in patients undergoing peripheral VA-ECMO. Its application may allow timely correction of perfusion deficits and the prevention of compartment syndrome and limb complications.</P>