RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        ESR Study on Molecular Salt (Benzo-TTFVS)2MBr4 (M = Fe, Ga)

        Shuichi Kawamata,Takekazu Ishida,Taro Hayakawa,Takashi Hiraoka,Hideki Fujiwara,Toyonari Sugimoto 한국물리학회 2008 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.53 No.2

        Electron spin resonance (ESR) experiments on (Benzo-TTFVS)2MBr4 (M = Fe, Ga) have been done with 15.4 GHz microwaves, where Benzo-TTFVS denotes a new donor molecule substituted with a benzo group, benzotetrathiafulvalenothioquinone-1,3-dithiolemethide. The temperature and the magnetic-field-direction dependencies of the effective g-value and the linewidth are obtained. In (Benzo-TTFVS)2GaBr4 (Ga salt), the ESR signals are due to π-electrons while they originate from d-electrons at the Fe3+ ion in the case of (Benzo-TTFVS)2FeBr4 (Fe salt). The g-value and the linewidth for the direction of the π-d correlation are dierent from those for other directions in the Fe salt. A strong antiferromagnetic fluctuation related to the π-d correlation is observed in the Fe salt. On the other hand, in the Ga salt, the magnetic-eld-direction dependencies of the g-value and the linewidth re ect the anisotropy of the one-dimensional conduction band. The importance of the π-d correlation is proved by comparing the ESR results for the Fe salt with those for the Ga salt. Electron spin resonance (ESR) experiments on (Benzo-TTFVS)2MBr4 (M = Fe, Ga) have been done with 15.4 GHz microwaves, where Benzo-TTFVS denotes a new donor molecule substituted with a benzo group, benzotetrathiafulvalenothioquinone-1,3-dithiolemethide. The temperature and the magnetic-field-direction dependencies of the effective g-value and the linewidth are obtained. In (Benzo-TTFVS)2GaBr4 (Ga salt), the ESR signals are due to π-electrons while they originate from d-electrons at the Fe3+ ion in the case of (Benzo-TTFVS)2FeBr4 (Fe salt). The g-value and the linewidth for the direction of the π-d correlation are dierent from those for other directions in the Fe salt. A strong antiferromagnetic fluctuation related to the π-d correlation is observed in the Fe salt. On the other hand, in the Ga salt, the magnetic-eld-direction dependencies of the g-value and the linewidth re ect the anisotropy of the one-dimensional conduction band. The importance of the π-d correlation is proved by comparing the ESR results for the Fe salt with those for the Ga salt.

      • KCI등재

        Development and Performance Test of the Analysis Software for the CRIB Active Target

        이필수,이춘식,문준영,채경육,차수미,Hidetoshi Yamaguchi,Taro Nakao,David M. Kahl,Shigeru Kubono,Silvio Cherubini,Seiya Hayakawa,Cosimo Signorini 한국물리학회 2015 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.66 No.3

        Software for genuinely event-by-event analysis and event reconstruction of data obtained by usingan active target has been developed in the graphical user interface under the CERN ROOT framework. The primary motivation for developing the software was to provide physicists who performexperiments using an active target a more user-friendly environment for the purpose of investigatingthe performance of detection systems and obtaining ideas about physics from a large amount ofexperimental data. To test the performance of the software, we analyzed experimental data froma 16N radioactive ion beam experiment for α-decay measurements. As a result of the analysis, weobserved the Bragg curve and measured the range of the 16N RI beam in the detector. Data werecalibrated against the calculation after comparing the Bragg curve to the one obtained from anenergy loss calculation in P-10 gas. We present a detailed description of the analysis software andits test results.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼