http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Sathe, Ashwin,Lee, Sang-Ho,Kim, Shin-Jae,Eun, Sang Soo,Choi, Yong Soo,Lee, Shih-min,Seuk, Ju-Wan,Lee, Yoon Sun,Shin, Sang-Ha,Bae, Junseok The Korean Neurosurgical Society 2022 Journal of Korean neurosurgical society Vol.65 No.6
Objective : ABM/P-15 (anorganic bone matrix/15-amino acid peptide fragment) is a commercially available synthetically manufactured P-15 collagen peptide fragment, that is adsorbed on ABM. This study was done to investigate the efficacy of ABM/P-15 in achieving fusion in the lumbar spine and comparing it with that of recombinant bone morphogenic protein-2 (rhBMP-2) and demineralized bone matrix (DBM). Methods : A retrospective observational study of prospectively collected data of 140 patients who underwent lumbar spinal fusion surgeries in a single specialty spine hospital between 2016 and 2020, with a minimum 6-month follow-up was conducted. Based on the material used for the augmentation of the bone graft at the fusion site, the patients were divided into three categories namely ABM/P-15, rhBMP-2, and DBM group. Results : ABM/P-15, rhBMP-2, and DBM were used in 46, 44, and 50 patients, respectively. Patient characteristics like age, gender, bone mineral density, smoking history, and presence of diabetes mellitus were comparable amongst the three groups. Average follow-up was 16.0±5.2, 17.9±9.8, and 26.2±14.9 months, respectively in ABM/P-15, rhBMP-2, and DBM groups. The fusion was achieved in 97.9%, 93.2%, and 98% patients while the average time-to-union was 4.05±2.01, 10±4.28, and 9.44±3.49 months (p<0.001), respectively for ABM/P-15, rhBMP-2, and DBM groups. The average pre-operative Visual analogue scale score was 6.93±2.42, 7.14±1.97, 7.01±2.14 (p=0.900) for ABM/P-15, rhBMP-2 and DBM groups, respectively, which reduced to 1.02±0.80, 1.21±0.96, and 0.54±0.70 (p=0.112), respectively at the last follow up. Pre-operative Oswestry disability index scores were 52.7±18.02, 55.4±16.8, and 53.56±19.6 (p=0.751) in ABM/P-15, rhBMP-2, and DBM groups, which post-operatively reduced to 33.77±15.52, 39.42±16.47, and 38.3±15.89 (p=0.412) and further to 15.74±8.3, 17.41±10.45, and 16.76±9.81 (p=0.603), respectively at the last follow-up. Conclusion : ABM/P-15 appears to achieve union significantly earlier than rhBMP-2 and DBM in lumbar spinal fusion cases while maintaining a comparable clinical and complication profile.
배준석,Ashwin Sathe,이세민,Alexander A. Theologis,Vedat Deviren,이상호 대한척추신경외과학회 2021 Neurospine Vol.18 No.3
Objective: The purpose of this study was to investigate the changes in spinopelvic parameters before and after the setting of muscle fatigue along with its correlation with pre-existing paraspinal and psoas muscle mass. Methods: Single-center retrospective review of prospectively collected data was conducted on 145-adults with symptomatic loss of lumbar lordosis (LL). Radiographs were taken before and after walking for 10 minutes. Magnetic resonance imaging was used to calculate paraspinal muscle (PSM) cross-sectional area (CSA), mean signal intensity, fatty infiltration (FI), and lean muscle mass at thoracolumbar junction (T12) and lower lumbar level (L4). Psoas CSA was calculated at L3. Patients were divided into 2 groups namely compensated sagittal deformity (CSD) (SVA ≤4 cm, PT>20°) and decompensated sagittal deformity (DSD) (SVA>4 cm, PT>20°) based on prewalk measurements. Results: Initial mean SVA was 1.8 cm and 11 cm for CSD and DSD respectively (p<0.01). After walking, significant deteriorations in SVA, PT–LL (p<0.01) were observed in CSD without significant change in thoracic kyphosis (TK). All sagittal parameters in DSD deteriorated significantly. DSD group had significantly poorer PSM quality at T12 and L4 compared to CSD group. In CSD group, sagittal decompensation correlated with muscle quality, i.e., decreases in LL (ΔLL) correlated with CSA of PSM/vertebral body (VB) at L4 (r= -0.412, p=0.046) while increases in TK (ΔTK) correlated with CSA of PSM/VB at T12 (r=0.477, p=0.018). ΔSVA and ΔPT correlated with FI at L4 (r=0.577, p=0.003 and r=-0.407, p=0.048, respectively). DSD group, had weak correlations (-0.3<r<-0.1) between changes in sagittal and PSM parameters. Conclusion: PSM quality in adults with spinal deformity correlates with patients’ ability to maintain an upright posture and sagittal decompensation after walking for 10 minutes.
Naik, Shalin H,Sathe, Priyanka,Park, Hae-Young,Metcalf, Donald,Proietto, Anna I,Dakic, Aleksander,Carotta, Sebastian,O'Keeffe, Meredith,Bahlo, Melanie,Papenfuss, Anthony,Kwak, Jong-Young,Wu, Li,Shortm NATURE AMERICA INC 2007 NATURE IMMUNOLOGY Vol.8 No.11
The development of functionally specialized subtypes of dendritic cells (DCs) can be modeled through the culture of bone marrow with the ligand for the cytokine receptor Flt3. Such cultures produce DCs resembling spleen plasmacytoid DCs (pDCs), CD8<SUP>+</SUP> conventional DCs (cDCs) and CD8<SUP>−</SUP> cDCs. Here we isolated two sequential DC-committed precursor cells from such cultures: dividing 'pro-DCs', which gave rise to transitional 'pre-DCs' en route to differentiating into the three distinct DC subtypes (pDCs, CD8<SUP>+</SUP> cDCs and CD8<SUP>−</SUP> cDCs). We also isolated an in vivo equivalent of the DC-committed pro-DC precursor cell, which also gave rise to the three DC subtypes. Clonal analysis of the progeny of individual pro-DC precursors demonstrated that some pro-DC precursors gave rise to all three DC subtypes, some produced cDCs but not pDCs, and some were fully committed to a single DC subtype. Thus, commitment to particular DC subtypes begins mainly at this pro-DC stage.
Pratik Suthar,Sonal Shah,Pushkar Waknis,Gandhali Limaye,Aditi Saha,Pranav Sathe 대한구강악안면외과학회 2020 대한구강악안면외과학회지 Vol.46 No.1
Objectives: The need for proper wound closure is of paramount importance after any intra-oral surgery. Various wound closure techniques have been described in literature using traditional non-absorbable suture materials. These include like synthetic absorbable sutures, surgical staples and tissue adhesives. Cyanoacrylates are among the most commonly used biocompatible tissue adhesives. To evaluate and compare intraoral wound healing using 3-0 silk sutures and n-butyl-2-cyanoacrylate after alveoloplasty. Materials and Methods: A total of 20 patients requiring bilateral alveoloplasty in the same arch (upper or lower) were included in this study. Patients with any pre-existing pathology or systemic disease were excluded. After alveoloplasty was performed, the wound was closed using 3-0 braided silk sutures on one side, and using n-butyl-2-cyanoacrylate bio adhesive on the other side. Patients were evaluated based on the following parameters: time required to achieve wound closure; the incidence of immediate and postoperative hemostasis; the time to the use of the first rescue medication; the side where pain first arises; and the side where wound healing begins first. Results: Compared to 3-0 silk sutures, cyanoacrylate demonstrated better hemostatic properties, reduced operative time, reduced postoperative pain and better wound healing. Conclusion: These data suggest that cyanoacrylate glue is an adequate alternative to conventional sutures to close the surgical wound after alveoloplasty, and better than are 3-0 silk sutures.
Balaji B. Mulik,Ajay V. Munde,Raviraj P. Dighole,Bhaskar R. Sathe 한국공업화학회 2021 Journal of Industrial and Engineering Chemistry Vol.93 No.-
The electrochemical determination of semicarbazide (SCB) executed by using cobalt oxide (Co3O4)nanoparticle modified electrode which was fabricated by using simple precipitation method. The assynthesizednanoparticles have been well characterised by X-ray diffraction (XRD), Furrier transforminfra-red (FTIR), UV-visible (UV-Vis) spectroscopic techniques, energy dispersive analysis of X-ray(EDAX), BET surface area, thermogravimetric (TG) analysis and transmission electron microscopic (TEM)techniques. The XRD shows face centred cubic (FCC) structure, the FTIR demonstrated a major bandsappeared at 574 cm 1 and 669 cm 1 are suggesting the (Co-O) vibrational mode of Co3O4. The TEM ofCo3O4 NPs has been confirmed its ultra-small particle size is of2 nm 0.5 nm. Whereas, EDAX showsthe only cobalt and oxygen are available confirms Co3O4 having high BET surface area. The fabricatedCo3O4 acted as a highly sensitive electrochemical sensor for the determination of SCB by using linearSweep voltammetry (LSV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) in0.5 M KOH solution. Significantly, anodic onset potential observed at 0.2 V vs. SCE, linear range of scanrate and concentration (1 mM–100 mM) with (LOD 0.13 and LOQ 0.46) and high current and potentialstability with pH dependent behaviour confirms Co3O4 based electrocatalytic system is good for oxidativedetermination of SCB. The selectivity of the sensor also tested by using mixture of other environmentalactive species with SCB by using LSV measurements. This proposed system is applicable in food andpharmaceutical industries for the determination of SCB as an amperometric sensor.
Nanocrystalline CdSe: Structural and Photoelectrochemical Characterization
P.A. Chate,S.S. Patil,J.S. Patil,D.J. Sathe,P.P. Hankare 대한금속·재료학회 2012 ELECTRONIC MATERIALS LETTERS Vol.8 No.6
Nanocrystalline cadmium selenide thin films have been deposited on non-conducting glass substrates using oxalic acid. The film thickness was found to be 0.73 μm with a growing time of 6 h. The structural, morphological,optical, electrical properties of samples were studies. Photoelectrochemical performance was also studied. Room temperature deposition results in films with the cubic structure and crystallite size of about 19.33 nm. The optical band gap energy of the film sample was found to be 1.91 eV. The efficiency of photoelectrode was found to be 1.1% using sulphide-polysulphide electrolyte.
Sonu,Mohit Tyagi,A. Kelkar,A. Sahu,M. Sonawane,P.S. Sarkar,A. Pandey,D.B. Sathe,G.D. Patra,T. Vincent,S.G. Singh,R.B. Bhatt Korean Nuclear Society 2023 Nuclear Engineering and Technology Vol.55 No.7
For the precise measurements of special nuclear materials (SNM) including Pu and Am isotopes, we have used phoswich detector combination of two single crystal scintillators of Gd<sub>3</sub>Ga<sub>3</sub>Al<sub>2</sub>O<sub>12</sub>:Ce and CsI:Tl. High detection efficiency and sensitivity along with high figure of merit for the discrimination of these phoswich detectors ensures the detection and discrimination of thermal neutrons and gammas from spontaneous fission of Pu and other isotopes in presence of high gamma background. Using this detector, the low energy gammas, which is stopped completely in 1mm thick disc of GGAG, can be also discriminated from high energies gamma and shows linearity in wide range of sample quantities. By changing only the appropriate shielding, the similar setup was used for thermal neutron detection and shows a very good linearity over wide range. The quantity of a test sample was also calculated accurately by using the measured calibrated plot.
Rohit Sharma,Ashish Kumar,Anit Dawar,Sunil Ojha,Ambuj Mishra,Anshu Goyal,Radhapiyari Laishram,V. G. Sathe,RITU SRIVASTAVA,Om Prakash Sinha 한국전기전자재료학회 2023 Transactions on Electrical and Electronic Material Vol.24 No.2
Field effect transistors (FETs) are considered as the backbone of electronic industry. In this study, we adopted a simple drop cast method for the fabrication of MoS2 and WS2 channel based FET on commercially available pre-patterned OFET devices. The synthesis of few-layers thick MoS2 and WS2 nanosheets (NSs) has been done by solvent-assisted exfoliation method. FESEM and TEM study reveals that NSs have lateral dimensions in micron and have polycrystalline nature. From XPS, it is observed that MoS2 NSs has 2H phase whereas WS2 have hybrid 1T and 2H phase. The frequency difference in Raman vibrational mode for MoS2 and WS2 NSs is 24.08 cm-1 and 63.84 cm-1 respectively, confirms that number of layers is reduced after sonication. UV-visible spectroscopy reveals that the bandgap is 1.7 eV and 1.8 eV for MoS2 and WS2 NSs respectively. Later, these nanosheets have been drop-casted as the channel material on pre-patterned FETs devices and their output and transfer characteristics have been studied. It found that the current On/Off ratio is 10 4 and 10 3 for MoS 2 and WS2-FET device respectively. This facile fabrication of FET devices may provide a new stage for researchers who do not have access of lithography facilities for FET fabrication.