RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가

        노시철 ( Si Cheol Noh ),김주영 ( Ju Young Kim ),박재현 ( Jae Hyun Park ),김진수 ( Jin Su Kim ),강정훈 ( Jung Hoon Kang ),최흥호 ( Heung Ho Chou ) 한국센서학회 2010 센서학회지 Vol.19 No.6

        In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

      • KCI등재

        3차원 레이저 스캐너 및 BIM을 활용한 터널 과대.과소 굴착 평가

        박정준,신재철,황주환,이강현,서형준,이인모,Park, Jeong-Jun,Shin, Jae-Chou,Hwang, Ju-Hwan,Lee, Kang-Hyun,Seo, Hyung-Joon,Lee, In-Mo 한국터널지하공간학회 2012 한국터널지하공간학회논문집 Vol.14 No.4

        최근 3차원 레이저 스캐너는 토목 분야의 적용에 관한 다수의 연구가 수행되고 있으며, 연구 분야 역시 터널 및 교량, 토공량 산정, 시공검측, 암반절리 측정 등 여러 분야에서 이루어지고 있다. 그 중 터널 시공 시 여굴량 및 미굴량을 산정함에 있어 3차원 레이저 스캐너를 활용하는 연구가 점차적으로 이루어지고 있으며, 지금까지의 연구는 스캔 데이터와 2차원 CAD 도면과의 비교를 통해 여굴량 및 미굴량을 산정하는 방식으로 이루어 졌다. 그러나 터널이 비교적 단순한 형상의 구조물이라 하더라도 3차원 형상의 구조물로 정확한 여굴량 및 미굴량을 산정하기 위해서는 3차원적인 비교가 필요하다. 본 연구에서는 3차원 레이저 스캐너로 획득한 스캔 데이터와 3차원 설계 모델링인 BIM을 활용하여 시공시 발생하는 여굴량 및 미굴량을 산정하는 시공오차 평가 프로그램을 개발하였으며, 이를 위한 효율적인 스캔 데이터의 처리 프로세스를 제안하였다. 또한 실제 현장에 3차원 레이저 스캐너를 적용하여 시공오차를 산정하였으며, 프로그램의 성능을 검증하였다. Application of 3D laser scanner to civil engineering is widely studied in various fields such as tunnel, bridge, calculation of earth volume, construction measurement, observation of rock joint, etc. Some studies on utilization of the 3D laser scanner for calculating the over-break and/or under-break of tunnels have also been carried out. However, in the previous research, the scanning data were usually compared with the 2D CAD blueprint results; although the shape of tunnel structure is relatively simple, for precise calculation of the over-break and/or under-break of tunnels, three-dimensional analysis based on BIM is needed. Therefore, in this paper, a new program that calculates the over-break and/or under-break of tunnels using the 3D laser scanner and the BIM is developed; moreover the effective and rapid process of data treatment is proposed. The accuracy of the developed program was verified by applying the new system to a real tunnels construction field.

      • KCI등재후보

        Metallic Stent Placement in Hemodialysis Graft Patients after Insufficient Balloon Dilation

        Huei-Lung Liang,Huay-Ben Pan,Yih-Huie Lin,Chiung-Yu Chen,Hsiao-Min Chung,Tung-Ho Wu,Kang-Ju Chou,Pin-Hong Lai,Chien-Fang Yang 대한영상의학회 2006 Korean Journal of Radiology Vol.7 No.2

        Objective: We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Materials and Methods: Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patients (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8 10mm in diameter and 40 80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. Results: No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates ( standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69% 9 and 88% 6, 41% 10 and 88% 6, 30% 10 and 77% 10, and 12% 8 and 61% 13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51% 16 and 86% 13 vs 45% 15 and 73% 13 at 6 months, and 25% 15 and 71% 17 vs 23% 17 and 73% 13 at 12 months (p = .346 and .224), respectively. Conclusion: Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼