RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Long-term Stable Field Electron Transfer from Carbon Nanotube Arrays at High Emission Current Densities

        Jian-hua Deng,Zhao-xia Ping,Rui-ting Zheng,Guo-an Cheng 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.58 No.41

        The stability behaviors of multiwalled carbon nanotube arrays during field electron emission are studied. The results indicate that the stability, even at a high emission current density, has been greatly improved by an aging process, and a degradation of about 0.66% in the emission current density at 21.86 mA/cm_2 during a 10-hour stability test has been obtained. A detailed analysis of the deterioration of the field electron emission characteristics is given, and the generation of Joule heat during field emission is found to be able to burn off the extruded carbon nanotubes, which will directly reduce the number of emission sites. On the other hand, the Joule heating effect may induce an annealing of the defects existing in the carbon nanotubes and may influence the distribution of electron energy states, both having a bad influence on the field emission characteristics. An aging process, especially aging at high emission current densities, can greatly reduce the influence of Jouleheating induced current degradation. Hence, an aging process at high emission current densities provides an effective way to realize long-term stable field electron emission from carbon nanotube arrays.

      • KCI등재

        Simulation analysis and evaluation of decontamination effect of different abrasive jet process parameters on radioactively contaminated metal

        Zhong Lin,Deng Jian,Zuo Zhe-wen,Huang Can-yu,Chen Bo,Lei Lin,Lei Ze-yong,Lei Jie-heng,Zhao Mu,Hua Yun-fei 한국원자력학회 2023 Nuclear Engineering and Technology Vol.55 No.11

        A new method of numerical simulating prediction and decontamination effect evaluation for abrasive jet decontamination to radioactively contaminated metal is proposed. Based on the Computational Fluid Dynamics and Discrete Element Model (CFD-DEM) coupled simulation model, the motion patterns and distribution of abrasives can be predicted, and the decontamination effect can be evaluated by image processing and recognition technology. The impact of three key parameters (impact distance, inlet pressure, abrasive mass flow rate) on the decontamination effect is revealed. Moreover, here are experiments of reliability verification to decontamination effect and numerical simulation methods that has been conducted. The results show that: 60Co and other homogeneous solid solution radioactive pollutants can be removed by abrasive jet, and the average removal rate of Co exceeds 80%. It is reliable for the proposed numerical simulation and evaluation method because of the well goodness of fit between predicted value and actual values: The predicted values and actual values of the abrasive distribution diameter are Ф57 and Ф55; the total coverage rate is 26.42% and 23.50%; the average impact velocity is 81.73 m/s and 78.00 m/s. Further analysis shows that the impact distance has a significant impact on the distribution of abrasive particles on the target surface, the coverage rate of the core area increases at first, and then decreases with the increase of the impact distance of the nozzle, which reach a maximum of 14.44% at 300 mm. It is recommended to set the impact distance around 300 mm, because at this time the core area coverage of the abrasive is the largest and the impact velocity is stable at the highest speed of 81.94 m/s. The impact of the nozzle inlet pressure on the decontamination effect mainly affects the impact kinetic energy of the abrasive and has little impact on the distribution. The greater the inlet pressure, the greater the impact kinetic energy, and the stronger the decontamination ability of the abrasive. But in return, the energy consumption is higher, too. For the decontamination of radioactively contaminated metals, it is recommended to set the inlet pressure of the nozzle at around 0.6 MPa. Because most of the Co elements can be removed under this pressure. Increasing the mass and flow of abrasives appropriately can enhance the decontamination effectiveness. The total mass of abrasives per unit decontamination area is suggested to be 50 g because the core area coverage rate of the abrasive is relatively large under this condition; and the nozzle wear extent is acceptable

      • SCIESCOPUSKCI등재

        Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

        Wan, Jie,Sun, Wan,Deng, Jian,Pan, Liang-ming,Ding, Shu-hua Korean Nuclear Society 2021 Nuclear Engineering and Technology Vol.53 No.6

        The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

      • KCI등재

        Lovastatin derivative dehydrolovastatin ameliorates ulcerative colitis in mice by suppressing NF-κB and inflammatory cytokine expression

        Xu Zhang,Qing-Hua Deng,Jian-Hua Deng,Sheng-Ju Wang,Qiu Chen 대한생리학회-대한약리학회 2020 The Korean Journal of Physiology & Pharmacology Vol.24 No.2

        Ulcerative colitis (UC) is associated with intestinal immune imbalance and inflammatory response. Because dehydrolovastatin (DLVT), a derivative of lovastatin, has been recently shown to inhibit inflammation and relieve immune arthritis induced by chemical stimuli, we studied its effect and possible mechanism on UC induced by dextran sulfate sodium. The BALB/c mice were classified into six groups: normal control group, model group, DLVT high dose group, DLVT low dose group, salazosulfapyridine (SASP) group and lovastatin (LVT) group. The disease activity indices of UC and pathological changes were investigated. The myeloperoxidase (MPO) activity in colon tissue and inflammatory factors such as IL-6, IL-10, IL-17, and TNF- in the serum were analyzed by ELISA, while the expression of NF-B p65 protein in colon tissue was detected by immunohistochemistry and western blot. DLVT relieved the disease activity indices and pathological damage of the UC mice. Furthermore, DLVT significantly decreased MPO activity and improved the imbalance of inflammatory cytokines through inhibiting the expression of NF-B p65. Meanwhile, the positive drug of SASP has a similar effect to DLVT, but the effect of DLVT in both decreasing IL-17, TNF-, and increasing IL-10 was significantly stronger than that of SASP. These results suggest that DLVT may ameliorates the symptoms of UC.

      • Prognostic Role of Hypoxic Inducible Factor Expression in Non-small Cell Lung Cancer: A Meta-analysis

        Li, Cong,Lu, Hua-Jun,Na, Fei-Fei,Deng, Lei,Xue, Jian-Xin,Wang, Jing-Wen,Wang, Yu-Qing,Li, Qiao-Ling,Lu, You Asian Pacific Journal of Cancer Prevention 2013 Asian Pacific journal of cancer prevention Vol.14 No.6

        Introduction: Reported prognostic roles of hypoxic inducible factor (HIF) expression in non-small cell lung cancer (NSCLC) have varied. This meta-analysis aimed to examine the relationship between HIF expression and clinical outcome in NSCLC patients. Methods: PubMed were used to identify relevant literature with the last report up to December $20^{th}$, 2012. After careful review, survival data were collected from eligible studies. We completed the meta-analysis using Stata statistical software (Version 11) and combined hazard ratio (HR) for overall survival (OS). Subgroup specificity, heterogeneity and publication bias were also assessed. All of the results were verified by two persons to ensure accuracy. Results: Eight studies were finally stepped into this meta-analysis in which seven had available data for HIF-$1{\alpha}$ and three for HIF-$2{\alpha}$. Combined HRs suggested that higher expression of $HIF1{\alpha}$ had a negative impact on NSCLC patient survival (HR=1.50; 95%CI=1.07-2.10; p=0.019). The expression of HIF-$2{\alpha}$ was also relative to a poorer survival (HR=2.02; 95%CI=1.47-2.77; p=0.000). No bias existed in either of the two groups. Conclusion: This study suggests that elevations of HIF-$1{\alpha}$ and HIF-$2{\alpha}$ expression are both associated with poor outcome for patients with NSCLC. The data support further and high quality investigation of HIF expression for predicting poor outcome in patients with NSCLC.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼