http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Wang Lu,Dai Ying-Jie,Cui Yu,Zhang Hong,Jiang Chang-Hao,Duan Ying-Jie,Zhao Yong,Feng Ye-Fang,Geng Shi-Mei,Zhang Zai-Hui,Lu Jiang,Zhang Ping,Zhao Li-Wei,Zhao Hang,Ma Yu-Tong,Song Cheng-Guang,Zhang Yi,Ch 대한뇌졸중학회 2023 Journal of stroke Vol.25 No.3
Background and Purpose Intravenous tenecteplase (TNK) efficacy has not been well demonstrated in acute ischemic stroke (AIS) beyond 4.5 hours after onset. This study aimed to determine the effect of intravenous TNK for AIS within 4.5 to 24 hours of onset. Methods In this pilot trial, eligible AIS patients with diffusion-weighted imaging (DWI)-fluid attenuated inversion recovery (FLAIR) mismatch were randomly allocated to intravenous TNK (0.25 mg/kg) or standard care within 4.5–24 hours of onset. The primary endpoint was excellent functional outcome at 90 days (modified Rankin Scale [mRS] score of 0–1). The primary safety endpoint was symptomatic intracranial hemorrhage (sICH). Results Of the randomly assigned 80 patients, the primary endpoint occurred in 52.5% (21/40) of TNK group and 50.0% (20/40) of control group, with no significant difference (unadjusted odds ratio, 1.11; 95% confidence interval 0.46–2.66; <i>P</i>=0.82). More early neurological improvement occurred in TNK group than in control group (11 vs. 3, <i>P</i>=0.03), but no significant differences were found in other secondary endpoints, such as mRS 0–2 at 90 days, shift analysis of mRS at 90 days, and change in National Institutes of Health Stroke Scale score at 24 hours and 7 days. There were no cases of sICH in this trial; however, asymptomatic intracranial hemorrhage occurred in 3 of the 40 patients (7.5%) in the TNK group. Conclusion This phase 2, randomized, multicenter study suggests that intravenous TNK within 4.5–24 hours of onset may be safe and feasible in AIS patients with a DWI-FLAIR mismatch.
Ectopic Overexpression of COTE1 Promotes Cellular Invasion of Hepatocellular Carcinoma
Zhang, Hai,Huang, Chang-Jun,Tian, Yuan,Wang, Yu-Ping,Han, Ze-Guang,Li, Xiang-Cheng Asian Pacific Journal of Cancer Prevention 2012 Asian Pacific journal of cancer prevention Vol.13 No.11
Family with sequence similarity 189, member B (FAM189B), alias COTE1, a putative oncogene selected by microarray, for the first time was here found to be significantly up-regulated in hepatocellular carcinoma (HCC) specimens and HCC cell lines. mRNA expression of COTE1 in HCC samples and cell lines was detected by reverse transcription-polymerase chain reaction (RT-PCR) and real-time PCR, while protein expression of COTE1 in HCC tissues was assessed by immunohistochemistry. In addition, invasion of HCC cells was observed after overexpressing or silencing COTE1. In the total of 48 paired HCC specimens, compared with the adjacent non-cancer tissues, the expression of COTE1 was up-regulated in 31 (p<0.01). In HCC cell lines, COTE1 expression was significantly higher than in normal human adult liver (p<0.01). Overexpression of COTE1 enhanced HCC-derived LM6 and MHCC-L cellular invasion in vitro. In contrast, COTE1 knockdown via RNAi markedly suppressed these phenotypes, as documented in LM3 and MHCC-H HCC cells. Mechanistic analyses indicated that COTE1 could physically associate with WW domain oxidoreductase (WWOX), a tumor suppressor. COTE1 may be closely correlated with invasion of hepatocellular carcinoma (HCC) cells and thus may serve as an effective target for gene therapy.
Reliable control of magnetic vortex chirality in asymmetrically optimized magnetic nanodisk
Zhang Huanhuan,Yu Hai,Zhang Xue-Feng,Yang Xiao-Xue,Shim Je-Ho,Ma Xiao-Ping,Piao Hong-Guang 한국물리학회 2022 Current Applied Physics Vol.43 No.-
Magnetic vortex has attracted attention in the field of information storage because their topological spin structures with chiral bistable states. If the vortex core polarity and vortex circulation sense can be controlled simultaneously in a nanodisk, which will be more beneficial to realize the multi-bit ultrahigh density storage. In this paper, a reliable control scheme for magnetic vortex chirality is proposed by optimizing the structure of Pac- Man-like nanodisk. The results show that the polarity and circulation of the vortex can be controlled simultaneously by changing the direction of the global magnetic field, and even the chiral states of the vortex can be determined by detecting the stray field distribution on the surface of the nanodisk. The optimized Pac-Man-like nanodisk provide an experimental method for the control and detection of magnetic vortex chirality, which will be beneficial to the realization of multi-bit magnetic storage or magnetic logic technology in the future.
Guang-Ping Li,Xiao-Yan Wang,Yong Zhang 대한배뇨장애요실금학회 2018 International Neurourology Journal Vol.22 No.4
Purpose: OnabotulinumtoxinA (BoNT-A) is a promising therapy for treating neurogenic detrusor overactivity (NDO) in individuals with spinal cord injury (SCI). This systematic review and meta-analysis aimed to carry out an in-depth review and to make an objective estimation of the efficacy and safety of BoNT-A on NDO after SCI. Methods: The PubMed, Embase, and Cochrane databases were searched for all relevant articles published from 2001 to 2016 that referred to NDO, SCI, and BoNT-A or botulinum toxin A. All data were recorded in an Excel spreadsheet by 2 individual reviewers. Review Manager version 5.3 was used to carry out the meta-analysis. Results: This analysis included 17 studies involving 1,455 patients. Compared with placebo and baseline, BoNT-A was effective in increasing maximum cystometric capacity, volume at first involuntary detrusor contraction, cystometric bladder capacity (all P<0.00001), compliance (P=0.001), and the number of patients with complete dryness (P=0.0003), and decreasing detrusor pressure, the number of patients with no involuntary detrusor contractions, the maximum flow rate, the incidence of detrusor overactivity (all P<0.00001), and the number of urinary incontinence episodes (P=0.001). There were no statistically significant differences between doses of 200 U and 300 U or between injections into the detrusor and submucosa. There were no life-threatening adverse events. Conclusions: BoNT-A is effective and safe in treating NDO after SCI. There were no statistically significant differences between doses of 200 U and 300 U or between injecting into the detrusor and submucosa. However, more high-quality randomized controlled trials are still needed.
Ping Fan,Zhuang-Hao Zheng,Jing-Ting Luo,Guang-Xing Liang,Dong-Ping Zhang 대한금속·재료학회 2015 ELECTRONIC MATERIALS LETTERS Vol.11 No.3
In this study, AZO thin films prepared by direct current reactive magnetron sputtering using a Zn-Al alloy target and In with varied content were doped through the prefabricated layer doping method in order to optimize their thermoelectric properties. The effects of In content on the room temperature microstructure and thermoelectric properties of the AZO thin films were investigated. It was found that the absolute value of the Seebeck coefficient of the thin films increases stably after In doping and reaches 153 μV·K−1 when the In content is 0.71%. Though the electrical conductivity of In-doped thin films is smaller than those of the un-doped films, the power factor of the thin films shows a significant increase after In doping with a maximum value of 2.22 × 10−4 W·m−1·K−2, which is several times that of the un-doped films.
Xu, Guang-Ri,Qi, Xin-hua,Yang, Fengxia,Lee, Jae-Joon,Xu, Ming-Lu,Zhang, Yu-Ping,Kim, Sunghyun WILEY-VCH Verlag 2009 Electroanalysis Vol.21 No.22
<P>A glassy carbon electrode having two polymer layers has been applied to selectively detect epinephrine. The inner layer formed by electropolymerization of macrocyclic nickel complex functioned as an electrocatalyst for epinephrine oxidation and the outer layer composed of hydrolyzed polyurethane γ-benzyl L-glutamate as a screening layer. Differential pulse voltammetry showed almost 100% recovery of epinephrine even in 100-fold excess of interferents. When applied to a dual glassy carbon electrode as an amperometric detector in flow injection analysis, a linear response over 0.1 μM and 10 μM was obtained. Recovery tested for 5-fold diluted human urine samples was 97.5%.</P>
Fan, Guang-Hua,Wang, Zhong-Ming,Yang, Xi,Xu, Li-Ping,Qin, Qin,Zhang, Chi,Ma, Jian-Xin,Cheng, Hong-Yan,Sun, Xin-Chen Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.2
Resveratrol has been examined in several model systems for potential effects against cancer. Adenosine monophosphate-activated protein kinase (AMPK) is reported to suppress proliferation in most eukaryocyte cells. Whether resveratrol via AMPK inhibits proliferation of oesophageal adenocarcinoma cells (OAC) is unknown. The aim of this study was to determine the roles of AMPK in the protective effects of resveratrol in OAC proliferation and to elucidate the underlying mechanisms. Treatment of cultured OAC derived from human subjects or cell lines with resveratrol resulted in decreased cell proliferation. Further, inhibition of AMPK by pharmacological reagent or genetical approach abolished resveratrol-suppressed OAC proliferation, reduced the level of $p27^{Kip1}$, a cyclin-dependent kinase inhibitor, and increased the levels of S-phase kinase-associated protein 2 (Skp2) of $p27^{Kip1}$-E3 ubiquitin ligase and 26S proteasome activity reduced by resveratrol. Furthermore, gene silencing of $p27^{Kip1}$ reversed resveratrol-suppressed OAC proliferation. In conclusion, these findings indicate that resveratrol inhibits Skp2-mediated ubiquitylation and 26S proteasome-dependent degradation of $p27^{Kip1}$ via AMPK activation to suppress OAC proliferation.
Study on rectangular concrete-filled steel tubes with unequal wall thickness
Yang Zhang,Chen-Jiang Yu,Guang-Yuan Fu,Bing Chen,She-Xu Zhao,Si-Ping Li 국제구조공학회 2016 Steel and Composite Structures, An International J Vol.22 No.5
Rectangular concrete-filled steel tubular columns with unequal wall thickness were investigated in the paper. The physical centroid, the centroidal principal axes of inertia, and the section core were given. The generalized bending formula and the generalized eccentric compression formula were deduced, and the equation of the neutral axis was also provided. The two rectangular concrete-filled steel tubular stub specimens subjected to the compression load on the physical centroid and the geometric centroid respectively were tested to verify the theoretical formulas.