RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        An Accurate Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry Method for Serum C-Peptide and Its Use in Harmonization in China

        Deng Yuhang,Zhang Chao,Wang Jing,Zeng Jie,Zhang Jiangtao,Zhang Tianjiao,Zhao Haijian,Zhou Weiyan,Zhang Chuanbao 대한진단검사의학회 2023 Annals of Laboratory Medicine Vol.43 No.4

        Background: Serum C-peptide results from various routine methods used in China are highly variable, warranting well-performing methods to serve as an accuracy base to improve the harmonization of C-peptide measurements in China. We developed an accurate isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS) method for serum C-peptide measurement and explored its use in harmonization. Methods: After protein precipitation with ZnSO4 solution, C-peptide was extracted from serum samples by anion-exchange solid-phase extraction and quantified by ID-LC–MS/MS in positive ion mode. The precision and analytical recovery of the ID-LC–MS/MS method were assessed. Seventy-six serum samples were analyzed using the ID-LC–MS/MS method and six routine immunoassays. Ordinary linear regression (OLR) and Bland-Altman (BA) analyses were conducted to evaluate the relationship between the ID-LC–MS/MS method and routine immunoassays. Five serum pool samples assigned using the ID-LC–MS/MS method were used to recalibrate the routine assays. OLR and BA analyses were re-conducted after recalibration. Results: The within-run, between-run, and total precision for the ID-LC–MS/MS method at four concentrations were 1.0%–2.1%, 0.6%–1.2%, and 1.3%–2.2%, respectively. The analytical recoveries for the ID-LC–MS/MS method at three concentrations were 100.3%–100.7%, 100.4%–101.0%, and 99.6%–100.7%. The developed method and the immunoassays were strongly correlated, with all R2 >0.98. The comparability among the immunoassays was substantially improved after recalibration. Conclusions: The performance of the ID-LC–MS/MS method was carefully validated, and this method can be used to improve the harmonization of serum C-peptide measurements in China.

      • KCI등재

        Commutability Assessment of Candidate External Quality Assessment Materials for Aminotransferase Activity Measurements Based on Different Approaches in China

        Long Qichen,Qi Tianqi,Zhang Tianjiao,Wang Jing,Zeng Jie,Ying Yan,Meng Wang,Wei Huang,Haijian Zhao,Wenxiang Chen,Chuanbao Zhang 대한진단검사의학회 2021 Annals of Laboratory Medicine Vol.41 No.1

        Background: Using commutable external quality assessment (EQA) materials is important for monitoring successful harmonization efforts. We assessed the commutability of four human serum pool (HSP) preparations to identify candidate EQA materials for alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activity measurement. Methods: One set each of 85 clinical samples (CSs) was collected for ALT and AST activity measurement. The 15 candidate EQA materials included four types of HSP preparations (A to D): materials A, C, and D contained human original recombinant (HOR) aminotransferases; materials B was mixed leftover samples. The CSs and 15 candidate EQA materials were analyzed using seven routine assays, and the ln-transformed results were analyzed in 21 assay pairs. Commutability was assessed using Deming regression, with a 95% prediction interval (CLSI approach) and the difference in bias with an error component model (International Federation of Clinical Chemistry and Laboratory Medicine [IFCC] approach). Results: For ALT, all materials were commutable for 14–21 assay pairs according to the CLSI and IFCC approaches. For AST, B01-03 showed commutability for 14-21 assay pairs, and C01-03 and D01-03 showed commutability for no less than 10 assay pairs according to the two approaches. A01-06 were commutable for 9-16 assay pairs according to the CLSI approach, but for 6-9 assay pairs according to the IFCC approach. Conclusions: Mixed leftover samples showed desirable commutability characteristics as candidate EQA materials for routine aminotransferase activity measurements. Human serum bases supplemented with HOR were commutable for most routine ALT activity measurements.

      • KCI등재

        Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China

        Zhou Weiyan,Deng Yuhang,Zhao Haijian,Zhang Chuanbao 대한진단검사의학회 2022 Annals of Laboratory Medicine Vol.42 No.4

        Background: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. Methods: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems. The inter- and intra-laboratory %CV as well as inter- and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. Results: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter-measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter- and intra-laboratory %CVs for insulin decreased with increasing concentration. After recalibration with low- and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. Conclusions: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements.

      • KCI등재

        Commutability Assessment of Processed Human Plasma Samples for Normetanephrine and Metanephrine Measurements Based on the Candidate Reference Measurement Procedure

        Deng Yuhang,Liu Qingxiang,Liu Zhenni,Zhao Haijian,Zhou Weiyan,Zhang Chuanbao 대한진단검사의학회 2022 Annals of Laboratory Medicine Vol.42 No.5

        Background: To identify candidate external quality assessment (EQA) materials for normetanephrine and metanephrine measurements, we assessed the commutability of eight processed human plasma samples. The agreement between routine assays and the candidate reference measurement procedure (cRMP) was also evaluated. Methods: Fifty-three clinical samples and eight processed plasma samples were prepared. The processed samples included pooled and individual plasma samples spiked with pure normetanephrine and metanephrine and non-spiked pooled and individual plasma samples. The clinical and processed samples were subjected to four routine isotope dilution tandem mass spectrometry assays and cRMP. Commutability was assessed based on two approaches recommended by the CLSI and International Federation of Clinical Chemistry (IFCC). Passing–Bablok regression and Bland–Altman analysis were used to evaluate the agreement between the routine assays and cRMP. Results: The commutability results of the CLSI approach were better than those of the IFCC approach. For the CLSI approach, spiked individual plasma samples and spiked high-concentration pooled plasma samples were commutable for all routine assays for both analytes. The non-spiked pooled plasma sample was commutable for two out of four routine assays for metanephrine and three out of four routine assays for normetanephrine. The agreement between the routine assays and the cRMP was satisfactory, except for one routine assay showing significant bias. Conclusions: High-concentration spiked pooled plasma samples and spiked individual plasma samples are candidate EQA materials for normetanephrine and metanephrine measurements.

      • KCI등재

        Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography–Tandem Mass Spectrometry for Total Thyroxine Measurement

        Songlin Yu,Weiyan Zhou,Xinqi Cheng,Qinghui Meng,Honglei Li,Li’an Hou,Jun Lu,Shaowei Xie,Qian Cheng,Chuanbao Zhang,Ling Qiu 대한진단검사의학회 2019 Annals of Laboratory Medicine Vol.39 No.4

        Background: Accurate serum total thyroxine (TT4) measurement is important for thyroid disorder diagnosis and management. We compared the performance of six automated immunoassays with that of isotope-diluted liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) as the reference method. We also evaluated the correlation of thyroid stimulating hormone (TSH) with TT4 measured by ID-LC-MS/MS and immunoassays. Methods: Serum was collected from 156 patients between October 2015 and January 2016. TT4 was measured by immunoassays from Abbott (Architect), Siemens (ADVIA Centaur XP), Roche (E601), Beckman-Coulter (Dxi800), Autobio (Autolumo A2000), and Mindray (CL-1000i), and by ID-LC-MS/MS. Results were analyzed using Passing–Bablok regression and Bland–Altman plots. Minimum requirements based on biological variation were as follows: a mean bias of ≤4.5% and total imprecision (CV) of ≤3.7%. Results: All immunoassays showed a correlation >0.945 with ID-LC-MS/MS; however, the slope of the Passing–Bablok regression line varied from 0.886 (Mindray) to 1.23 (Siemens) and the intercept from -12.8 (Siemens) to 4.61 (Mindray). Only Autobio, Beckman-Coulter, and Roche included the value of one in the 95% confidence interval for slope. The mean bias ranged from -10.8% (Abbott) to 9.0% (Siemens), with the lowest value noted for Roche (3.5%) and the highest for Abbott (-10.8%). Only Abbott and Roche showed within-run and total CV ≤3.7%. Conclusions: Though all immunoassays correlated strongly with ID-LC-MS/MS, most did not meet the minimum clinical requirement. Laboratories and immunoassay manufacturers must be aware of these limitations.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼