화재안전성능 확보를 위한 방화댐퍼의 최적 설치위치 선정에 관한 연구
서희원(Seo, Heewon),최동호(Choi, Dongho),강은수(Kang, Eunsoo),김대회(Kim, Daehoi),박수영(Park, Sooyoung),이승재(Lee, Seungjea) 한국방재학회 2020 한국방재학회논문집 Vol.20 No.5
최근 관련 건축법에서는 방화댐퍼가 화재 시 연기 또는 불꽃을 감지하여 자동적으로 닫히는 구조가 되도록 하고 있어 모터 등 가연물이 포함되므로 화재에 취약할 수 있다. 이에 본 연구에서는 성능검증을 통하여 화재안전성능 확보를 위한 방화댐퍼의 최적 설치위치를 선정하고자 하였다. 성능검증 결과, 방화댐퍼가 방화구획 벽체 표면에 접하여 설치되도록 하는 것이 화재안전성능 확보에 가장 유리한 것으로 나타났다. Building regulations in recent times require that fire dampers be automatically closed when detecting smoke or flame in the event of a fire. However, they may be vulnerable to fire themselves because they contain combustibles, such as motors. Therefore, the optimal installation locations of fire dampers for securing fire safety performance were selected through performance verifications in this study. Thus, it was found that fire dampers installed in contact with the fire compartment wall surfaces would be advantageous for securing the required fire safety performance.
화재 시 자동방화셔터의 복사열 전달에 의한 화재확산 가능성에 관한 연구
서희원(Seo Heewon),김대회(Kim Daehoi),최동호(Choi Dongho) 한국방재학회 2018 한국방재학회논문집 Vol.18 No.6
Mock-up tests were performed to evaluate the possibility of fire spreading owing to radiation heat transfer of automatic fire shutters in the event of fire where combustible materials are placed around them. Test results show that combustible materials placed at a distance of 0.5 m to 1 m from the automatic fire shutter can become ignited through radiated heat in the event of fire. Therefore, it is necessary to improve the related standards such as limiting the placement of combustible materials within a definite distance from automatic fire shutters or installing automatic fire shutters with adequate insulation performance for the portion where combustible materials are inevitably placed adjacent to them. 화재 시 자동방화셔터 주변에 가연물이 배치되었을 경우 자동방화셔터를 통한 복사열 전달에 의한 화재확산 가능성을 평가하기 위하여 목업 실험을 실시하였다. 실험 결과, 자동방화셔터로부터 0.5m ~ 1m 이격 거리에 있는 가연물은 화재 시 복사열에 의한 착화가 가능하여 화재확산에 영향을 줄 수 있는 것으로 나타나 자동방화셔터 주변 일정거리 이내에는 가연물이 배치되지 않도록 제한하거나, 가연물의 인접 배치가 불가피한 부분에 대해서는 차열성능이 있는 자동방화셔터를 설치하도록 하는 등 관련 기준을 개선할 필요성이 있다.
서희원(Heewon Seo),김대회(Daehoi Kim),이길용(Gilyong Lee) 한국방재학회 2022 한국방재학회논문집 Vol.22 No.6
관련 건축법에서 방화댐퍼는 덕트의 방화구획 관통부분 또는 이에 근접한 부분에 설치되도록 규정되어 있다. 이에 따라 현장에서는 방화댐퍼를 방화구획 벽체 또는 바닥에 매립하여 설치하거나 인접하여 설치하고 있는데, 법에서 규정한 ‘근접한 부분’에 대해서는 명확한 기준이 없어 대부분의 현장에서는 방화구획 벽체 또는 바닥에서 이격하여 설치하고 있다. 방화댐퍼를 방화구획 벽체에서 많이 이격하여 설치하게 되면 이격된 부분의 덕트, 슬리브 등이 화재로 인한 고열로 변형될 수 있으며, 이를 통해서 연기 및 화염 등이 이웃 구획 공간으로 직접 전달될 수 있으므로 화재안전성이 확보되지 않을 수 있다. 이에 본 연구에서는 성능검증을 통하여 방화댐퍼의 이격 설치에 따른 화재안전성을 확인하고자 하였다. 성능검증 결과, 화재안전성 확보를 위해서는 방화댐퍼의 이격 거리를 최소화(벽체에 접합하여 설치)하여야 하는 것으로 나타났다. According to building regulations, fire dampers should be installed in or close to the part of the duct that penetrates the fire compartment. Accordingly, in construction sites, fire dampers are installed in or adjacent to the fire compartment wall and floor. However, they are often installed too far away from the fire compartment wall and floor because the law does not stipulate a clear standard for “close”. If this occurs, the duct and sleeve in the spaced part may be transformed by the high heat of a fire. Through this, smoke and flames can be directly transmitted to the neighboring compartment space, failing to ensure fire safety. Therefore, this study investigated the dependence of fire safety on the spaced installation of fire dampers by performance verification. From the performance verification results, it was found that the separation distance of the fire damper should be minimized (i.e., attached to the wall) to ensure fire safety.
알츠하이머 치매 환자에서 치료 전 중증도에 따른 약물의 장기 치료 효과
서희원(Heewon Seo),박유리(Yuri Park),권인선(Insun Kwon),김정란(Jeong Lan Kim) 대한생물치료정신의학회 2021 생물치료정신의학 Vol.27 No.1
Objectives:To describe the differences in long-term outcomes in Alzheimer’s disease (AD) patients according to initial dementia severity. Methods:A retrospective chart review of AD patients from a dementia clinic at the University Hospital in Korea was conducted from April 2010 to March 2017. There were 168 patients enrolled, who were divided into three groups based on initial Clinical Dementing Rating (CDR). There were 55 in the very mild group (CDR=0.5 ; mean age 80.64±6.57), 93 in the mild group (CDR=1 ; mean age 80.57±7.28) and 20 in the moderate group (CDR=2 ; mean age 83.00±9.07). Participants were treated with donepezil±memantine. The observation period was 2.44±0.50 years. Cognitive function and severity of dementia were initially assessed by the Consortium to Establish a Registry for Alzheimer’s Disease Neuropsychological Assessment Battery (CERAD-NP) and were annually assessed by Mini-Mental State Exam (MMSE), CDR and CDR-Sum of boxes (CDR-SB). Results:The annual decline rate of MMSE score was -0.82 and those of very mild, mild, moderate groups were -0.63, -0.80, -1.96 respectively, while the annual change in CDR-SB score was 0.98, very mild group 0.86, mild group 1.03, moderate group 1.26. Education level, male, initial CDR were found to be significant potential factors in the annual change in MMSE, while initial CDR was a significant potential factor in the annual change in CDR-SB. Conclusion:It is meaningful that we studied long-term outcomes of anti-dementia medications in real-world clinical setting. The higher the initial severity of AD, the higher the cognitive decline rate.
시뮬레이션을 이용한 비차열 덕트 내화충전구조의 적용 가능성에 관한 연구
서희원(Seo, Heewon),윤명오(Yoon, Myungo),최동호(Choi, Dongho),김대회(Kim, Daehoi),이형도(Lee, Hyungdo) 한국방재학회 2020 한국방재학회논문집 Vol.20 No.2
화재 시 비차열 덕트 내화충전구조의 주위로의 복사열 전달 및 영향을 분석하여 건축물에의 적용 가능성을 검토하고자 시뮬레이션을 수행하였다. 시뮬레이션 대상은 바닥 및 벽체 사각 덕트 내화충전구조로서 차열재(1 m 길이) 적용 유무에 따라 구분하였으며, 중요한 입력 데이터인 표면온도는 기존 성능검증 실험 데이터를 활용하였고, 가상 공간을 설정하여 주위 공기온도, 주위 구조체 표면온도 및 덕트로부터 일정 이격 거리에서의 복사온도를 분석하였다. 시뮬레이션 결과, 비차열덕트 내화충전구조에 차열재를 설치한 경우 복사온도가 현격히 감소하는 등 복사열에 의한 화재확산 가능성을 상당히 줄일 수 있어 건축물에 적용 가능할 것으로 판단되었다. A simulation of the uninsulated duct firestop system was performed to review its application possibility to the building by analyzing the radiant heat transfer and its impact to the surrounding structures in the event of a fire. The simulation targets were divided by the presence or absence of an insulation material (1 m long) as floor and wall duct firestop systems, and the surface temperature, which is an important input data, was based on the existing verification test data. Then, the ambient air temperature, surrounding structure surface temperature, and radiant temperature at some distance from the duct were analyzed through simulations in the modeled virtual spaces. As a result of simulation, it is judged that the application of the uninsulated duct firestop system wrapped by the insulation material can significantly reduce the possibility of fire spreading due to the radiant heat.