이중외피시스템의 차음성능 평가에 관한 연구 - 전면형 이중외피시스템을 중심으로 -
차민철(Cha Min-chul),곽현철(Kwak Hyun-chul),황재환(Hwang Jae-hwan),석호태(Seok Ho-tae) 대한건축학회 2003 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.23 No.2
The purpose of this study is to evaluate the sound insulation performance and to present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-layer type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.
프리캐스트 포스트텐션 콘크리트 넓은 보-기둥 내부 접합부의 비탄성 거동
황재환,최윤철,김영찬,김대중,임재형,권기혁,문정호,이리형 대한건축학회 2003 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.23 No.2(구조계)
The purpose of this paper is to evaluate the response of Precast Prestressed Concrete Interior Wide Beam-Column Joint subjected to cyclic lateral loading. To this end, the experimental investigation was performed with six half-scale specimens of interior connection. The design parameters are the beam to column depth ratio, and the number of tendons within column core. One of the specimens, IJH-6, is modeled for the connection at the top floor of a structure. The test results showed that the specimens sufficiently resist up to limiting drift ratio of 0.035 in accordance with the provisional standard by ACI of acceptance criteria for concrete special moment frames.