RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI우수등재

        수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -

        허인량,정의호,권재혁 한국환경보건학회 2002 한국환경보건학회지 Vol.28 No.2

        Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

      • KCI등재

        강원도내 주요하천 수계별 목표수질 설정 및 달성도 연구

        허인량,최지용,김영진,김성석,Huh, In-Ryang,Choi, Ji-Yong,Kim, Yeong-Jin,Kim, Sung-Seok 한국환경보건학회 2006 한국환경보건학회지 Vol.32 No.5

        Since 1985, the Gangwon Institute of Health and Environment(GIHE) and Ministry of Environment have collected rivers and streams water quality data in an ambient surface water monitering program. This study was prepared to propose an achievement of water quality of rivers subject to management by area according to an created level while establishing a water quality level applicable to the Gangwon area. As a result of evaluating correlativity on the BOD-based water quality data, BOD versus TP, and TP versus SS demonstrated significance at a confidence level of 95%. Evaluating correlativity on $10{\sim}90$ percentile values of analyzed data, a coefficient of determination, $r^{2}$ of BOD versus TP, and TP versus SS were 0.625, 0.286 respectively. Grading the results by evaluation method, the representative values of TP were 0.030 mg/l for I level, 0.100 mg/l for II level, 0.200 mg/l for Ill level, 0.300 mg/l for IV level, and 0.350 mg/l for V level, and those of SS were indicated 4.0 mg/l for I level, 15.0 mg/l for II level, 30.0 mg/l for III level, 45.0 mg/l for IV level, and 60.0 mg/l for V level. As for the limiting factor allowing the water quality standard exceeded, BOD posted 61% as the factor was found in 11 places, TP 28%, and SS 33%.

      • KCI우수등재

        섬강유역 환경용량 및 수질 Modeling

        허인량,오근찬,최지용 한국환경보건학회 1998 한국환경보건학회지 Vol.24 No.1

        Seom River was major branch of Namhan river, consist of primary basin that Wonjoo-city, Hoingsung-gun and primary contamination source was sewage from human lives. This study was evaluated production contamination loading of each branch basin and water quality grade and water quality simulation by QUAL2E to provide efficient contaminations source control. Rusult of survey, production loading of BOD, T-N, T-P were 26,591 kg/day, 4,560 kg/day, 731 kg/day resectively. Water quality analysis in 17 points of main stream were appeared that 1st grade(BOD 1 mg/l under) was 6 point, 2nd grade was 9 point and 3rd grade was 2 point. And result of water quality analysis for branch steram, first grade was evaluated 68.7%. Based of field data, calibration and verification result were in good agreement with mesured value within coefficient of variance were from 2.59% to 18.73%, from 6.39%, to 28.46%, respectively.

      • KCI등재

        구제역 가축매몰지 인근 지하수 관측정 수질 모니터링

        허인량,김계월,최금종,이택수,Huh, In-Ryang,Kim, Kei-Woul,Choi, Geum-Jong,Lee, Teak-Soo 한국환경보건학회 2014 한국환경보건학회지 Vol.40 No.1

        Objectives: The purpose of this study is to evaluate the characteristics of leachate discharged from livestock burial sites in Gangwondo resulting from foot-and-mouth disease by monitoring the water quality at the survey tube-wells installed near livestock burial sites in order to investigate the effect of the leachate on the quality of nearby underground water and suggest a water pollution level in accordance with water quality evaluation criteria. Methods: To minimize the secondary environmental pollution damage caused by leachate at burial sites of livestock killed by foot-and-mouth disease, this study analyzed the leachate directly discharged from burial sites and installed survey tube-wells within 300 meters of livestock burial sites and investigated water quality as a means to ascertain the environmental effect of the leachate from the burial sites. In accordance with environmental management guidelines on livestock burial sites, this research investigated the water quality in the survey tube-wells in fifty five burial sites in Gangwondo. The elements investigated were $NH_3$-N, $Cl^-$, $NO_3$-N, conductivity, and E. coli. Water quality was monitored from 2011 to 2013. Results: The water quality from the drain pipe at the location of leachate from livestock burial sites showed BOD 37,209 mg/L, COD 8,829 mg/L, $NH_3$-N 3,633 mg/L, and $Cl^-$ 580 mg/L. According to the monitoring results of water quality ($Cl^-$, $NH_3$-N, conductivity) at the survey tube-wells, there was suspicion that 13 out of 55 burial sites discharged leachate, five sites discharged highly concentrated leachate (13%): one in Gangneung, one in Wonju, and three in Cheorwon. Conclusion: It was judged that out of thirteen observation wells which showed a possibility of discharged leachate, three survey tube-wells have established the discharge effect of leachate at burial sites up to recently. Therefore, it is judged that it is necessary to continue monitoring them and devise additional measures.

      • KCI등재

        의암호 유역에서 발생하는 자체생산 유기물 저감방안에 관한 연구

        허인량,이건호,함광준,최지용,정의호 한국환경보건학회 2004 한국환경보건학회지 Vol.30 No.1

        The present study was designed to evaluate primary production organic matter in basin of lake around by execution of total maximum daily loading. BOD influent loading of Uiam lake was 2,819 kg/day, which was less then 28.3 percent, total effuluent loading as 3,619 kg/day, in comparision with BOD, total nitrogen influent loading was 4,681 kg/day, which was less then 10.0 percent, total effuluent loading as 5,150 kg/day. But in case of total phosphors influent loading was 73.3 kg/day, which was more then 34.2 percent, total run off loading as 48.3 kg/day. The result of survey reduction plan of primary production organic matter in basin of lake around which objectives of abstract is as follows. First plan was reduction of primary production organic matter by moving the outlet of municipal wastewater treatment center from present place to lake downstream. Secondary plan was improvement by diffusion type of outlet municipal wastewater treatment center. The third plan was reduction of environmental impact by passing and storing of municipal wastewater. Finally plan was decline water surface level which was present hydrouric retention time was reduction from 7.6 day to 6.0 day per meter.

      • KCI등재

        내린천수계 비점오염원 오염물질 유출량조사

        허인량,박성빈,오흥석,김영진,Huh, In-Ryang,Park, Sung-Bin,Oh, Heung-Seok,Kim, Yeong-Jin 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.3

        This study evaluates the water quality of the river near the alpine farmland in the upper Naerin stream, which is a typical stream of the upper Bukhan River with muddy water generation, by the flow examination, it aims to estimate the characteristics of nonpoint sources flowing out from the investigated area and figure out effective methods to reduce them. According to the result of water quality examination, the average BOD of the area not affected by the cultivated land among the areas of the upper Naerin River was 0.47mg/l, and total phosphorous was 0.007mg/l; thus, it maintained the cleanliness level of Ia. The average BOD of the area with the alpine farmland was 0.52mg/l, which was similar to the one of the non-cultivated land. But total phosphorous concentration was 0.023mg/l, which was more than three times higher than the area belonging to level II due to the effect of fertilizer ingredients discharged from the cultivated land. About the loadings of the investigated area generated from each of the pollution sources, BOD was 878.5kg/day and total phosphorous was 79.7kg/day. Moreover, for the load density, BOD was $2.22kg/day.km^2$ and total phosphorous was shown as $0.20kg/day.km^2$. Regarding the rates generated from nonpoint sources like land among the loadings per pollution sources, BOD was 54%, total nitrogen was 91%, and total phosphorous was 73.4%. Therefore, it was shown that most of the nutrients were produced from the nonpoint sources. The level of BOD runoff loading in the Jaun River area, where nonpoint sources were mainly generated, was 37.1kg/day and total phosphorous was 1.33kg/day. The flow rates to the generated amount were estimated as 10.5% and 4.7% each.

      • KCI등재

        강원도 동해안 지역 정수장의 THMs 분포

        허인량,신용건,박성빈,이택수,심태흠,Huh, In-Ryang,Shin, Yong-Keon,Park, Sung-Bin,Lee, Teak-Soo,Shim, Tae-Heum 한국환경보건학회 2013 한국환경보건학회지 Vol.39 No.3

        Objectives: In an effort to examine the distribution of THMs (Trihalomethane) generated from chlorine disinfection by the drinking water treatment plants located on the east coast region of Gangwon-do, this study surveyed the distribution and concentrations of each component of THMs twice per month for 5 years from 2008 to 2012. Fluctuation pattern in the seasonal generation amount was identified. In addition, the correlation between the concentration of organic substances in water and THMs was assessed, along with stability of purified water quality supplied by the water treatment plants on the east coast by analyzing the composition ratio of each component that constitutes THMs and the detection frequency. Method: The research was done on purified water supplied by 29 water treatment plants in 7 cities and counties (Goseong-gun, Sokcho-si, Yangyang-gun, Gangneung-si, Donghae-si, Samcheok-si, Taebaek-si) located in Gangwon-do on the east coast. Water samples were collected twice a month from 2008 to 2012 and were investigate for chloroform, bromodichloromethane (BDCM), dibromochloromethane (DBCM), and bromoform, based on analysis through Purge-Trap (Tekmar 3000) devices using FID-attached GC (HP 6890, Hewlett Packard). Result: THMs concentration detected at Gangneung-si was 0.0086mg/L, Goseong-gun 0.0019mg/L, Donghae-si 0.0099 mg/L, Samcheok-si 0.0016 mg/L, Sokcho-si 0.0057 mg/L, Yangyang-gun 0.0027 mg/L and Taebaek-si 0.0038 mg/L. As the THMs composition rate, chloroform constitutes 51.4% followed bybromodichloromethane 22.3%, bromoform 15.2% and dibromochloromethane 11.1% respectively. Conclusion: Throughout the entire THMs survey areas and period, the maximum concentration was 0.072mg/L, which did not exceed the water quality standards (0.1 mg/L), and the overall average concentration was very low at 0.0044 mg/L.

      • KCI등재

        강원 영서지역 하수처리장이 수질에 미치는 영향

        허인량,최지용,김영진,정의호,Huh In-Ryang,Choi Ji-Yong,Kim Yeong-Jin,Jeong Ui-Ho 한국환경보건학회 2005 한국환경보건학회지 Vol.31 No.4

        The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were $88.9\%,\;80.6\%,\;90.7\%$ and T-P removal rates were $47.3\%,\;56.5\%,\;71.6\%,$ respectively. Also, BOD effluent leading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6 mg/l to 4.0 mg/l and T-P rose from 0.034 mg/l to 0.321 mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1 mg/l to 1.4 mg/l and T-P from 0.011 mg/l to 0.026 mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.

      • KCI등재

        Fenton 산화와 완전혼합형 혐기성 / 호기성 고정 생물막 공정에 의한 매립지 침출수의 유기물 및 색도의 제거

        허인량,김영관 ( In Ryang Hun,Yeong Kwan Kim ) 한국물환경학회 1997 한국물환경학회지 Vol.13 No.2

        The purpose of this study was to estabilsh an optimum working condition to remove remaining organics and color by three steps : 1) Fenton oxidation 2) Complete mixing anaerobic process and aerobic fixed biofilm process 3) Fenton oxidation to remove the non-biodegradable organics and color remained after 2nd step. COD of leachate samples was 2,000㎎/L in average and their BOD-5/COD ratio were approximately 0.04. The COD removal obtained from the 1st Fenton oxidation previous to biological process was 60%. Methanol was added to an complete mixing anaerobic/aerobic fixed biofilm process to enhance a biological activity. Then an optimal dilution ratio was near to 50% and COD removal was 71.6%. Fenton oxidation as the 3rd step was conducted to exhibit a 52% of COD removal.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼