http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
최호연(Choi, Ho-Yeon),이상민(Lee, Sang-Min),이구연(Lee, Goo-Yeon) 강원대학교 산업기술연구소 2011 産業技術硏究 Vol.31 No.1
Recently, smartphones have been widely used in wireless communications which caused severe data overload in cellular networks. Cellular companies consider increasing wireless data capacity in overloaded areas. Determining overloaded areas is mainly made from user reports which are currently collected by calling or simple apps by some active users experiencing overloads. Since the current reporting method is inconvenient and does not contain detail information about the overload conditions, and therefore is used by only some active users, the overloaded areas determined from the reports are not likely to be accurate. Therefore, we need a new reporting method which is convenient enough for even inactive users to willingly report the overload condition and which delivers detail information about the overloads. In this paper, we design and implement a measurement function of smartphone s WCDMA communication quality including overload condition and management system of mobile wireless communication networks about smartphones communication quality.
최호열(Hoyeol Choi),김대영(Daeyeong Kim),신형준(Hyungjune Shin),한창희(Changhee Hahn),허준범(Junbeom Hur) 한국정보보호학회 2016 정보보호학회논문지 Vol.26 No.3
SCADA 시스템은 국내 산업분야 전반에서 원격 감시 제어를 위해 이용되고 있는 만큼 제어시스템의 보안인증을 올바르게 확립해야 할 필요가 점차 커지고 있다. ISASecure에서 진행하는 EDSA-CRT 테스트는 장치가 정상적인 환경과 비정상적인 네트워크 프로토콜 트래픽 환경에서 핵심 서비스를 적절하게 제공할 수 있는지에 초점이 맞춰져 있기는 하지만 IP, ARP, TCP등 IP 기반 프로토콜을 대상으로 진행하고 있고, 제어 프로토콜에 적용한 테스트 연구는 전무하다. 따라서 본 논문에서는 제어 프로토콜 중 가장 널리 사용되는 DNP3 프로토콜에 대해 EDSA-CRT를 적용하여 테스트 요구사항을 도출하고자 한다. 이에 우리는 DNP3 프로토콜에 대한 33개의 테스트 케이스를 제시한다. SCADA(Supervisory Control and Data Acquisition) system is widely used for remote monitoring and control throughout the domestic industry. Due to a recent breach of security on SCADA systems, such as Stuxnet, the need of correctly established secure certification of a control system is growing. Currently, EDSA-CRT (Embedded Device Security Assurance-Communication Robustness Test), which tests the ability to provide core services properly in a normal/abnormal network protocol, is only focused on the testing of IP-based protocols such as IP, ARP, TCP, etc. Thus, in this paper, we propose test requirements for DNP3 protocol based on EDSA-CRT. Our analysis show that the specific test cases provide plentiful evidences that DNP3 should follow based on its functional requirements. As a result, we propose 33 specific test case for DNP3 protocol.
차량용 발전기 효율 향상을 위한 MOSFET 정류기 구현
최호식(Ho-Seek Choi),권우현(Woo-hyen Kwon),윤병근(Byung-keun Yoon) 대한전자공학회 2018 전자공학회논문지 Vol.55 No.5
최근 환경오염으로 인해 강화된 배기가스 규제와 낮은 연비의 차량을 요구하는 소비자의 만족을 충족하기 위해 차량의 배기가스 감소 및 연비 향상에 많은 연구가 진행되고 있다. 이를 위해 본 논문에서는 비교적 에너지 손실이 큰 차량용 발전기의 부품별 손실 상태 및 손실 원인을 분석하고 발전기 자체 효율 개선 방안을 제시한다. 발전기 여러 가지 부품 중 손실이 큰 정류기의 손실을 줄이기 위해 다이오드보다 전압 강하 손실이 작은 MOSFET을 이용한 정류기를 제안한다. 기존의 다이오드 정류기 제품과 비교 실험을 통해 MOSFET 정류기의 VDA(Verband Der Automobilindustrie) 효율이 기존 다이오드 정류기보다 약 6%가량 상승한 78%의 효율을 보였다. 또한, 기존의 제품보다 발전기에 의한 토크 소모가 작아, 차량의 idle rpm을 기존보다 낮게 설정할 수 있어 교통 정체가 심한 도심 구간에서 운행 시 보다 효과적인 연비 향상이 기대된다. Recently, many researcher have been studied for reducing the exhaust gas of the vehicle and for improving the fuel efficiency to satisfy the high fuel efficiency requirement of consumer and to satisfy the exhaust regulation of gorvement because of environmental pollution. Therefore, this paper analyzes the loss cause of each part of a vehicle generator and proposes a method to improve the efficiency of the generator. We suggest a MOSFEET rectifier which has lower voltage drop loss than a diode, to reduce the rectifier loss which is high loss part among various parts of generator. This paper confirmed that the VDA efficiency of MOSFET rectifier is 78% which increased the 6% efficiency of VDA efficiency than conventional diode rectifier. Moreover, it expected to improve the fuel efficiency more effectively at the traffic jam area than driving area since the idle rpm of the vehicle can be set lower than the conventional rectifier because of the lower torque consumption by generator than the conventional one.
1999년 경주 인근에서 3차례 발생한 지진들의 지진원 특성 분석
최호선 ( Ho Seon Choi ),심택모 ( Taek Mo Shim ) 대한지질공학회 2009 지질공학 Vol.19 No.4
1999년 경상북도 경주 인근에서 지역규모(ML) 3.0 이상의 지진이 3차례(4월 24일, 6월 2일, 9월 12일)에 걸쳐 발생하였다. 진앙의 위치를 재결정한 결과 이 지진들의 진앙 사이 거리는 반경 1 km 내에 포함된다. 파형역산을 수행하여 6월 2일 지진의 발진기구를 분석하였으며, 나머지 지진들은 P파와 S파의 초동극성 및 진폭비를 이용하여 발진기구를 분석하였다. 6월 2일 및 9월 12일 지진은 단층면해가 서로 비슷하고, 4월 24일 지진은 상기 지진들의 단층면해를 포함하나 그 분포범위가 상대적으로 넓다. 이 지진들의 발진기구는 공통적으로 약간의 정단층 성분을 포함한 주향이동단층의 특성을 보이며, P축의 방향은 동북동-서남서 방향으로 한반도 주응력 방향에 대한 이전 연구결과와 부합한다. 진앙 사이의 거리, 지진파형의 유사성, 지진들을 공통으로 기록한 지진관측소 지진자료 극성의 동일성, 발진기구의 유사성 등을 고려했을 때, 이 지진들은 동일한 단층에서 발생했을 것으로 추정된다. 파형역산을 수행한 결과 6월 2일 지진의 지진모멘트는 3.9 × 10(14)N·m로 계산되었으며, 이 값은 모멘트규모 3.7에 해당한다. 스펙트럼 분석을 통해 계산된 모멘트규모는 3.8로, 파형역산에 의한 모멘트규모와 비슷하다. 평균 응력강하는 7.5 MPa로 추정되었다. 3개 지진들을 공통으로 기록한 단일 지진관측소의 스펙트럼을 서로 비교한 결과 4월 24일 및 9월 12일 지진의 모멘트규모는 각각 3.2, 3.4로 추정되었다. Three earthquakes with local magnitude (ML) greater than 3.0 occurred on April 24, June 2 and September 12 in 1999 nearby the Gyeongju area. Redetermined epicenters were located within the radius of 1 km. We carried out waveform inversion analysis to estimate focal mechanism of June 2 event, and P and S wave polarity and their amplitude ratio analysis to estimate focal mechanisms of April 24 and September 12 events. June 2 and September 12 events had similar fault plane solutions each other. The fault plane solution of April 24 event included those of other 2 events, but its distribution range was relatively broad. Focal mechanisms of those events had a strike slip faulting with a small normal component. P-axes of those events were ENE-WSW which were similar to previous studies on the P-axis of the Korean Peninsula. Considering distances between epicenters, similarities of seismic waves and sameness of polarities of seismic data recorded at common seismic stations, these events might occurred at the same fault. The seismic moment of June 2 event was estimated to be 3.9 × 10(14) N·m and this value corresponded to the moment magnitude (MW) 3.7. The moment magnitude estimated by spectral analysis was 3.8, which was similar to that estimated by waveform inversion analysis. The average stress drop was estimated to be 7.5 MPa. Moment magnitudes of April 24 and September 12 events were estimated to be 3.2 and 3.4 by comparing the spectrum of those events recorded at common single seismic station.