        양전자방출단층촬영기의 표준 성능평가 방법 : GE AdvanceTM 에 적용한 예

        김상은(S . E . Kim),이경한(K . H . Lee),이정림(J . R . Lee),최용(Y . Choi),신승애(S . A . Shin),김병태(B . T . Kim),최연성(Y . S . Choe) 대한핵의학회 1996 핵의학 분자영상 Vol.30 No.4

        N/A A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric AdvanceTM PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE AdvanceTM PET has bismuth germanate oxide crystals (4.0mm transaxial × 8.lmm axial × 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of 4.86μCi/cc and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of 4.50μCi/cc. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE AdvanceTM PET scanner to be well suited for clinical and research applications.

      • KCI등재

        섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과

        김종호,최용,김준영,오차환,김상은,최연성,이경한,주관식,김병태,Kim, J. H.,Choi, Y.,Kim, J. Y.,Oh, C. H.,Kim, S. E.,Choe, Y. S.,Lee, K. H.,Joo, K. S.,Kim, B. T. 대한의용생체공학회 1999 의공학회지 Vol.20 No.6

        감마카메라에서 섬광체는 감마선을 검출하여 카메라의 영상 특성을 결정하는 주요한 센서역할을 한다. 이 연구에서는 감마카메라 제작시에 고려되어야 하는 섬광체의 옆표면처리가 감마카메라영상에 미치는 영향에 대하여 고찰하였다. 섬광체는 크기가 20mm (직경 $\times$10mm(두께)인 NaI(TI) 와 CsI(TI)를 설정하여 옆표면처리를 반사체와 흡수체로 하였다 . 선정한 4개의 섬광체에서 감마선에 의해 발생한 섬광이 광전자증배관의 광음극에 도달할 때 까지의 광학적 특성을 몬테카를로(Monte Carlo) 시뮬레이션 방법을 이용하여 고찰하였다. 또한 이 네 개의 섬광체를 위치민감형 광전자증배관에 광학적으로 결합하여 Tc-99m 140 keV 에 대한 민감도와 플러드 영상, 에너지 분해능 그리고 위치분해능을 측정하였다. 시뮬레이션 결과, NAI(TI)-반사체가 가장 우수한 민감도를 보인 것으로 계산되었으며, 감마카메라를 이용하여 획득한 플러드영상에서 민감도는 NAI(TI)-반사체 2920cps/$\mu$Ci, NaI(TI)-흡수체2322 cps/$\mu$Ci, CsI(TI) 반사체 1754 cps/$\mu$Ci, CsI(TI)/흡수체 1401 cps/$\mu$Ci로 축정되었다. 내인성 위치분해능은 NaI(TI)-반사체 5.17mm, , NaI(TI)-흡수체 4.54mm, CsI(TI)-반사체 6.99m, CsI(TI)-흡수체 6.31 mm FWHM의 결과를 나타냈다. Tc -99m 140 keV에 대한 에너지분해능은 NaI(TI)-반사체 12.5%, NAI(TI) -흡수체 23.5%, CSI(TI)-반사체 20.5%, CsI(TI) -흡수체 33.3% FWHM으로 측정되었다. 이 연구에서는 감마카메라에서 사용되는 섬광체의 옆표면처리가 카메라의 주요특성에 직접적인 영향을 미친다는 것을 시뮬레이션과 실체 측정방법으로 고찰할 수 있었으며, 두 가지 방법이 일치된 결과를 보여주었다. 결론적으로 섬광체와 광전자증배관 그리고 Tc-99m 선원을 이용하여 영상획득을 목적으로 하는 감마카메라 제작에서는 NAaI(TI) 섬광체가 CSI(TI) 보다 적합하며, 해상력을 고려할 경우에는 섬광체 옆표면을 흡수체로 민감도를 고려할 경우에는 반사체로 선택하여 처리해야 함을 확인하였다. Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

      • KCI등재후보

        PET 영상의 잡음개선을 위한 적응적 공간 필터 개발

        우상근,최용,임기천,송태용,정진호,이경한,김상은,최연성,박장춘,김병태,Woo, S. K.,Choi, Y.,Im, K. C.,Song, T. Y.,Jung, J. H.,Lee, K. H.,Kim, S. E.,Choe, Y. S.,Park, C. C.,Kim, B. T. 대한의용생체공학회 2002 의공학회지 Vol.23 No.3

        양전자방출단층촬영기(Positron emission tomography, PET) 영상 개선을 위하여 적응적 공간 필터를 개발하였으며. 개발한 필터의 성능을 시뮬레이션데이터. 모형 PET 영상과 환자 PET 영상을 이용하여 평가하였다. 경계화소로 검출된 화소와 윈도우내의 모든 화소값이 동일한 화소는 보존하고. 그 외 화소에 대하여 2:7:2 비율로 가중치를 주어 정열한 후 중앙의 9개 화소에 대한 평균값으로 대치하였다. 경계화소를 검출하기 위하여 두 개의 임계값(TH7, TH2)을 이용하였으며. 다음의 조건을 만족하면 경계화소로 판단하였다 . THl ($pix_max{\times}0.1/log_2(NPM)$, NPM :주변값중 최상위 값과 최하위 값을 제외한 주변값들의 평균) 보다 작은 ADs (중앙값과 주변값의 차에 대한 절대값) 개수는 8-k이고. TH2 ($NPM{\times}0.1$) 보다 큰 ADs 개수는 k. 여기서 k는 2, 3 ‥‥ 6의 값을 가진다 성능평가 결과 이 연구에서 제안한 필터가 가우시안 필터, 가중메디안 필터, 부분집합평균메디안 필터 등과 비교하여 우수한 성능을 제공하는 것을 관찰하였다. 본 논문에서 개발한 간단한 적응적 공간 필터는 공간 분해능 저하는 최소화하면서 균일도와 대조도를 향상시키는데 효과적 이여서 정확한 PET 영상 해석에 기여할 것으로 기대된다 A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .

      • KCI등재

        Gibbs 선행치를 사용한 배열된부분집합 기대값최대화 방출단층영상 재구성방법에 관한 연구

        임기천,최용,김종호,이수진,우상근,서현관,이경현,감상흔,최연성,박장춘,김병태,Im, K. C.,Choi, Y.,Kim, J. H.,Lee, S. J.,Woo, S. K.,Seo, H. K.,Lee, K. H.,Kim, S. E.,Choe, Y. S.,Park, C. C,Kim, B. T. 대한의용생체공학회 2000 의공학회지 Vol.21 No.5

        방출단층영상 재구성을 위한 최대우도 기대값최대화(maximum likelihood expectation maximization, MLEM) 방법은 영상 획득과정을 통계학적으로 모델링하여 영상을 재구성한다. MLEM은 일반적으로 사용하여 여과후역투사(filtered backprojection)방법에 비해 많은 장점을 가지고 있으나 반복횟수 증가에 따른 발산과 재구성 시간이 오래 걸리는 단점을 가지고 있다. 이 논문에서는 이러한 단점을 보완하기 위해 계산시간을 현저히 단축시킨 배열된부분집합 기대값최대화(ordered subsets expectation maximization. OSEM)에 Gibbs 선행치인 membrance (MM) 또는 thin plate(TP)을 첨가한 OSEM-MAP (maximum a posteriori)을 구현함으로써 알고리즘의 안정성 및 재구성된 영상의 질을 향상시키고자 g나다. 실험에서 알고리즘의 수렴시간을 가속화하기 위해 투사 데이터를 16개의 부분집합으로 분할하여 반복연산을 수행하였으며, 알고리즘의 성능을 비교하기 위해 소프트웨어 모형(원숭이 뇌 자가방사선, 수학적심장흉부)을 사용한 영상재구성 결과를 제곱오차로 비교하였다. 또한 알고리즘의 사용 가능성을 평가하기 위해 물리모형을 사용하여 PET 기기로부터 획득한 실제 투사 데이터를 사용하였다.

      • 비디오 정보 검색을 위한 브라우징 툴의 설계 및 구현

        이현창(H. C. Lee),양명섭(M. S. Yang),이재현(J. H. Lee),최연성(Y. S. Choi),장옥배(O. B. Jang) 한국정보과학회 1996 한국정보과학회 학술발표논문집 Vol.23 No.1A

        본 논문에서는 효율적인 비디오 정보검색 시스템을 위한 브라우징 툴의 설계 및 구현에 관하여 설명한다. 본 시스템에서는 먼저 비디오 정보를 인덱스하기 위해서 움직임 벡터의 교차율에 기반하여 각 비디오 샷으로 분리한 후, 각 샷에서 카메라 동작을 검출하여 인덱스를 구축한다. 정보검색을 위한 브라우저는 사용자의 편의를 제공하기 위해서 대표 프래임으로 첫 번째 프래임을 사용하여 고정된 크기로 아이콘화하여, 구간별로 VCR과 같은 형태로 검색할 수 있도록 하였다.