http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
대나무 숯 제조과정에서 나오는 죽력 Streptozotocin으로 誘發된 糖尿 생쥐에 미치는 影響(I)
정찬원,장경선,최찬헌,오영준 대한동의병리학회 2001 동의생리병리학회지 Vol.15 No.1
This study was carried out to understand the effects of Bambusae Caulis in Liquamen on blood sugar of the diabetic mice induced with Streptozotocin(STZ). Normal, STZ-administered control and Bambusae Caulis in Liquamen-treated groups were used. The Bambusae Caulis in Liquamen extracted from bamboo charcoal manufacturing process was filtered and refined. The ingredients of Bambusae Caulis in Liquamen were analyzed and the effect of Bambusae Caulis in Liquamen were observed in term of blood sugar, GPT and BUN. The pancreatic tissue was utilized for the immunohistochemical approach in order to localize Langerhans cells. The results are as follows 1.Eleven elements, Methanol, Ethanol, Propanol, Acetic acid, Propionic acid, Hydroxy-buthan, p-Cresol, o-Cresol, Dimethyl phenol, Nitro phenol and p-Isopropyl phenol, were detected from the Bambusae Caulis in Liquamen by the chemical test. 2.The amount of glucose was significantly decreased(P <0.05) in the Bambusae Caulis in Liquamen-treated group compared with the control. 3.The amount of blood urea nitrogen did not show any differences among three groups. 4.The amount of GPT did not show any differences among three groups. 5.The intense of basophila of the acini cells showed order of normal group, experimental and control. The intense of insulin-immunoreactivity of β cells showed the strongest in the normal group, and more strong in the experimental group compared with control group administered with streptozotocin. In conclusion, it was found that Bambusae Caulis in Liquamen is nontoxic to kidney and liver and also effective on murine hyperglycemia induced with STZ.
EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定)
정찬원,최찬헌,윤유식,소철호,나창수,장경선,Jeong, Chan-Won,Choi, Chan-Hun,Yoon, Wu-Sik,So, Cheal-Ho,Na, Chang-Su,Jang, Kyeong-Seon 경락경혈학회 2004 대한침구의학회지 Vol.21 No.2
Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.
EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定)
장경선 ( Kyeong Seon Jang ),정찬원 ( Chan Won Jeong ),최찬헌 ( Chan Hun Choi ),윤유식 ( Wu Sik Yoon ),소철호 ( Cheal Ho So ),나창수 ( Chang Su Na ) 대한경락경혈학회 2004 Korean Journal of Acupuncture Vol.21 No.2
Objectives: Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results: EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver`s EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.
EEG, fMRI, EAV 및 SQUID裝置를 利用한 氣功現狀 測定
장경선,최찬헌,나창수,정찬원,윤유식,소철호 경락경혈학회 2004 Korean Journal of Acupuncture Vol.21 No.2
Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.